Cargando…
Saphenous Vein Interposition Grafts in Lower Extremity Reconstruction: Appraisal of Technique and Case Series
Vascular microanastomosis is technically challenging in patients with calcified recipient and donor vessels. Inside-to-outside suturing can prevent plaque rupture and ensure full-thickness intimal approximation. Although this is the preferred technique for anastomosis of atherosclerotic vessels, dir...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9509154/ https://www.ncbi.nlm.nih.gov/pubmed/36168606 http://dx.doi.org/10.1097/GOX.0000000000004536 |
_version_ | 1784797172572618752 |
---|---|
author | Dekker, Paige K. Abdou, Salma A. Youn, Richard Bekeny, Jenna C. Kim, Kevin G. Zolper, Elizabeth G. Fan, Kenneth L. Evans, Karen K. |
author_facet | Dekker, Paige K. Abdou, Salma A. Youn, Richard Bekeny, Jenna C. Kim, Kevin G. Zolper, Elizabeth G. Fan, Kenneth L. Evans, Karen K. |
author_sort | Dekker, Paige K. |
collection | PubMed |
description | Vascular microanastomosis is technically challenging in patients with calcified recipient and donor vessels. Inside-to-outside suturing can prevent plaque rupture and ensure full-thickness intimal approximation. Although this is the preferred technique for anastomosis of atherosclerotic vessels, direct connection of calcified arteries necessitates outside-to-inside suturing on one side of the anastomosis. Furthermore, it is difficult to achieve optimal vessel wall approximation in the setting of luminal size mismatch and rigid vasculature. We previously reported on the use of a saphenous vein interposition graft as a novel technique to achieve a flow-sparing anastomosis in patients with diffuse atherosclerosis who are undergoing free tissue transfer. This study further assesses outcomes of this technique in a series of patients and demonstrates a flap success rate of over 93% in patients with calcified recipient and donor microvasculature. |
format | Online Article Text |
id | pubmed-9509154 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-95091542022-09-26 Saphenous Vein Interposition Grafts in Lower Extremity Reconstruction: Appraisal of Technique and Case Series Dekker, Paige K. Abdou, Salma A. Youn, Richard Bekeny, Jenna C. Kim, Kevin G. Zolper, Elizabeth G. Fan, Kenneth L. Evans, Karen K. Plast Reconstr Surg Glob Open Reconstructive Vascular microanastomosis is technically challenging in patients with calcified recipient and donor vessels. Inside-to-outside suturing can prevent plaque rupture and ensure full-thickness intimal approximation. Although this is the preferred technique for anastomosis of atherosclerotic vessels, direct connection of calcified arteries necessitates outside-to-inside suturing on one side of the anastomosis. Furthermore, it is difficult to achieve optimal vessel wall approximation in the setting of luminal size mismatch and rigid vasculature. We previously reported on the use of a saphenous vein interposition graft as a novel technique to achieve a flow-sparing anastomosis in patients with diffuse atherosclerosis who are undergoing free tissue transfer. This study further assesses outcomes of this technique in a series of patients and demonstrates a flap success rate of over 93% in patients with calcified recipient and donor microvasculature. Lippincott Williams & Wilkins 2022-09-23 /pmc/articles/PMC9509154/ /pubmed/36168606 http://dx.doi.org/10.1097/GOX.0000000000004536 Text en Copyright © 2022 The Authors. Published by Wolters Kluwer Health, Inc. on behalf of The American Society of Plastic Surgeons. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. |
spellingShingle | Reconstructive Dekker, Paige K. Abdou, Salma A. Youn, Richard Bekeny, Jenna C. Kim, Kevin G. Zolper, Elizabeth G. Fan, Kenneth L. Evans, Karen K. Saphenous Vein Interposition Grafts in Lower Extremity Reconstruction: Appraisal of Technique and Case Series |
title | Saphenous Vein Interposition Grafts in Lower Extremity Reconstruction: Appraisal of Technique and Case Series |
title_full | Saphenous Vein Interposition Grafts in Lower Extremity Reconstruction: Appraisal of Technique and Case Series |
title_fullStr | Saphenous Vein Interposition Grafts in Lower Extremity Reconstruction: Appraisal of Technique and Case Series |
title_full_unstemmed | Saphenous Vein Interposition Grafts in Lower Extremity Reconstruction: Appraisal of Technique and Case Series |
title_short | Saphenous Vein Interposition Grafts in Lower Extremity Reconstruction: Appraisal of Technique and Case Series |
title_sort | saphenous vein interposition grafts in lower extremity reconstruction: appraisal of technique and case series |
topic | Reconstructive |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9509154/ https://www.ncbi.nlm.nih.gov/pubmed/36168606 http://dx.doi.org/10.1097/GOX.0000000000004536 |
work_keys_str_mv | AT dekkerpaigek saphenousveininterpositiongraftsinlowerextremityreconstructionappraisaloftechniqueandcaseseries AT abdousalmaa saphenousveininterpositiongraftsinlowerextremityreconstructionappraisaloftechniqueandcaseseries AT younrichard saphenousveininterpositiongraftsinlowerextremityreconstructionappraisaloftechniqueandcaseseries AT bekenyjennac saphenousveininterpositiongraftsinlowerextremityreconstructionappraisaloftechniqueandcaseseries AT kimkeving saphenousveininterpositiongraftsinlowerextremityreconstructionappraisaloftechniqueandcaseseries AT zolperelizabethg saphenousveininterpositiongraftsinlowerextremityreconstructionappraisaloftechniqueandcaseseries AT fankennethl saphenousveininterpositiongraftsinlowerextremityreconstructionappraisaloftechniqueandcaseseries AT evanskarenk saphenousveininterpositiongraftsinlowerextremityreconstructionappraisaloftechniqueandcaseseries |