A New Type of Air Conditioning System Based on Finned Ceiling Radiant Coupled with Independent Fresh Air and Its Thermal Comfort Experimental Study
The traditional radiation air conditioning system has some problems, such as easy condensation, insufficient refrigeration capacity, complex structure, and control system. Therefore, this study proposes a new type of finned metal radiant plate with large heat flow per unit area, sufficient cooling c...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9509224/ https://www.ncbi.nlm.nih.gov/pubmed/36164419 http://dx.doi.org/10.1155/2022/4144569 |
_version_ | 1784797189229248512 |
---|---|
author | Qin, Wenqi Hu, Yingning Su, Jinwen Hu, Yubang |
author_facet | Qin, Wenqi Hu, Yingning Su, Jinwen Hu, Yubang |
author_sort | Qin, Wenqi |
collection | PubMed |
description | The traditional radiation air conditioning system has some problems, such as easy condensation, insufficient refrigeration capacity, complex structure, and control system. Therefore, this study proposes a new type of finned metal radiant plate with large heat flow per unit area, sufficient cooling capacity, and simplified heat exchange system, in order to realize large temperature difference between cooling and heating. The temperature field uniformity and thermal comfort test of a novel type of finned ceiling radiant panel and independent fresh air linked air conditioning system under summer cooling and winter heating circumstances are accomplished through artificially generated climate environments. The study's findings demonstrate that in the radiation and fresh air modes, the maximum interior temperature differential under cooling conditions does not rise over 2.1°C. The maximum temperature differential in the space at any one moment in the radiation and fresh air modes cannot be greater than 3°C when heating conditions are present. The fresh air's cooling and dehumidifying effects are clear. The dehumidification efficiency may reach 50%, and the moisture content ranges from 5.48 to 9.63 g/kg. With PMV ranging from −0.34 to 0.54, the enhanced air conditioning system in this research provides exceptionally good thermal comfort. Additionally, the finned radiant panel's installation area occupies just 14% of the ceiling, which is sufficient to fulfill the room's cooling and heating load needs as well as provide high thermal comfort and consistent indoor temperature. The theoretical investigation and practical implementation of the direct expansion radiant air conditioning system are both strongly supported by this research. |
format | Online Article Text |
id | pubmed-9509224 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-95092242022-09-25 A New Type of Air Conditioning System Based on Finned Ceiling Radiant Coupled with Independent Fresh Air and Its Thermal Comfort Experimental Study Qin, Wenqi Hu, Yingning Su, Jinwen Hu, Yubang Comput Intell Neurosci Research Article The traditional radiation air conditioning system has some problems, such as easy condensation, insufficient refrigeration capacity, complex structure, and control system. Therefore, this study proposes a new type of finned metal radiant plate with large heat flow per unit area, sufficient cooling capacity, and simplified heat exchange system, in order to realize large temperature difference between cooling and heating. The temperature field uniformity and thermal comfort test of a novel type of finned ceiling radiant panel and independent fresh air linked air conditioning system under summer cooling and winter heating circumstances are accomplished through artificially generated climate environments. The study's findings demonstrate that in the radiation and fresh air modes, the maximum interior temperature differential under cooling conditions does not rise over 2.1°C. The maximum temperature differential in the space at any one moment in the radiation and fresh air modes cannot be greater than 3°C when heating conditions are present. The fresh air's cooling and dehumidifying effects are clear. The dehumidification efficiency may reach 50%, and the moisture content ranges from 5.48 to 9.63 g/kg. With PMV ranging from −0.34 to 0.54, the enhanced air conditioning system in this research provides exceptionally good thermal comfort. Additionally, the finned radiant panel's installation area occupies just 14% of the ceiling, which is sufficient to fulfill the room's cooling and heating load needs as well as provide high thermal comfort and consistent indoor temperature. The theoretical investigation and practical implementation of the direct expansion radiant air conditioning system are both strongly supported by this research. Hindawi 2022-09-17 /pmc/articles/PMC9509224/ /pubmed/36164419 http://dx.doi.org/10.1155/2022/4144569 Text en Copyright © 2022 Wenqi Qin et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Qin, Wenqi Hu, Yingning Su, Jinwen Hu, Yubang A New Type of Air Conditioning System Based on Finned Ceiling Radiant Coupled with Independent Fresh Air and Its Thermal Comfort Experimental Study |
title | A New Type of Air Conditioning System Based on Finned Ceiling Radiant Coupled with Independent Fresh Air and Its Thermal Comfort Experimental Study |
title_full | A New Type of Air Conditioning System Based on Finned Ceiling Radiant Coupled with Independent Fresh Air and Its Thermal Comfort Experimental Study |
title_fullStr | A New Type of Air Conditioning System Based on Finned Ceiling Radiant Coupled with Independent Fresh Air and Its Thermal Comfort Experimental Study |
title_full_unstemmed | A New Type of Air Conditioning System Based on Finned Ceiling Radiant Coupled with Independent Fresh Air and Its Thermal Comfort Experimental Study |
title_short | A New Type of Air Conditioning System Based on Finned Ceiling Radiant Coupled with Independent Fresh Air and Its Thermal Comfort Experimental Study |
title_sort | new type of air conditioning system based on finned ceiling radiant coupled with independent fresh air and its thermal comfort experimental study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9509224/ https://www.ncbi.nlm.nih.gov/pubmed/36164419 http://dx.doi.org/10.1155/2022/4144569 |
work_keys_str_mv | AT qinwenqi anewtypeofairconditioningsystembasedonfinnedceilingradiantcoupledwithindependentfreshairanditsthermalcomfortexperimentalstudy AT huyingning anewtypeofairconditioningsystembasedonfinnedceilingradiantcoupledwithindependentfreshairanditsthermalcomfortexperimentalstudy AT sujinwen anewtypeofairconditioningsystembasedonfinnedceilingradiantcoupledwithindependentfreshairanditsthermalcomfortexperimentalstudy AT huyubang anewtypeofairconditioningsystembasedonfinnedceilingradiantcoupledwithindependentfreshairanditsthermalcomfortexperimentalstudy AT qinwenqi newtypeofairconditioningsystembasedonfinnedceilingradiantcoupledwithindependentfreshairanditsthermalcomfortexperimentalstudy AT huyingning newtypeofairconditioningsystembasedonfinnedceilingradiantcoupledwithindependentfreshairanditsthermalcomfortexperimentalstudy AT sujinwen newtypeofairconditioningsystembasedonfinnedceilingradiantcoupledwithindependentfreshairanditsthermalcomfortexperimentalstudy AT huyubang newtypeofairconditioningsystembasedonfinnedceilingradiantcoupledwithindependentfreshairanditsthermalcomfortexperimentalstudy |