Cargando…

Dual-energy CT with virtual monoenergetic images and iodine maps improves tumor conspicuity in patients with pancreatic ductal adenocarcinoma

OBJECTIVES: To evaluate the value of monoenergetic images (MEI [+]) and iodine maps in dual-source dual-energy computed tomography (DECT) for assessing pancreatic ductal adenocarcinoma (PDAC), including the visually isoattenuating PDAC. MATERIALS AND METHODS: This retrospective study included 75 PDA...

Descripción completa

Detalles Bibliográficos
Autores principales: Liang, Hongwei, Zhou, Yang, Zheng, Qiao, Yan, Gaowu, Liao, Hongfan, Du, Silin, Zhang, Xiaohui, Lv, Fajin, Zhang, Zhiwei, Li, Yong-mei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Vienna 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9509509/
https://www.ncbi.nlm.nih.gov/pubmed/36153376
http://dx.doi.org/10.1186/s13244-022-01297-2
_version_ 1784797238793338880
author Liang, Hongwei
Zhou, Yang
Zheng, Qiao
Yan, Gaowu
Liao, Hongfan
Du, Silin
Zhang, Xiaohui
Lv, Fajin
Zhang, Zhiwei
Li, Yong-mei
author_facet Liang, Hongwei
Zhou, Yang
Zheng, Qiao
Yan, Gaowu
Liao, Hongfan
Du, Silin
Zhang, Xiaohui
Lv, Fajin
Zhang, Zhiwei
Li, Yong-mei
author_sort Liang, Hongwei
collection PubMed
description OBJECTIVES: To evaluate the value of monoenergetic images (MEI [+]) and iodine maps in dual-source dual-energy computed tomography (DECT) for assessing pancreatic ductal adenocarcinoma (PDAC), including the visually isoattenuating PDAC. MATERIALS AND METHODS: This retrospective study included 75 PDAC patients, who underwent contrast-enhanced DECT examinations. Conventional polyenergetic image (PEI) and 40–80 keV MEI (+) (10-keV increments) were reconstructed. The tumor contrast, contrast-to-noise ratio (CNR) of the tumor and peripancreatic vessels, the signal-to-noise ratio (SNR) of the pancreas and tumor, and the tumor diameters were quantified. On iodine maps, the normalized iodine concentration (NIC) in the tumor and parenchyma was compared. For subjective analysis, two radiologists independently evaluated images on a 5-point scale. RESULTS: All the quantitative parameters were maximized at 40-keV MEI (+) and decreased gradually with increasing energy. The tumor contrast, SNR of pancreas and CNRs in 40–60 keV MEI (+) were significantly higher than those in PEI (p < 0.05). For visually isoattenuating PDAC, 40–50 keV MEI (+) provided significantly higher tumor CNR compared to PEI (p < 0.05). The reproducibility in tumor measurements was highest in 40-keV MEI (+) between the two radiologists. The tumor and parenchyma NIC were 1.28 ± 0.65 and 3.38 ± 0.72 mg/mL, respectively (p < 0.001). 40–50 keV MEI (+) provided the highest subjective scores, compared to PEI (p < 0.001). CONCLUSIONS: Low-keV MEI (+) of DECT substantially improves the subjective and objective image quality and consistency of tumor measurements in patients with PDAC. Combining the low-keV MEI (+) and iodine maps may yield diagnostically adequate tumor conspicuity in visually isoattenuating PDAC.
format Online
Article
Text
id pubmed-9509509
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Vienna
record_format MEDLINE/PubMed
spelling pubmed-95095092022-10-20 Dual-energy CT with virtual monoenergetic images and iodine maps improves tumor conspicuity in patients with pancreatic ductal adenocarcinoma Liang, Hongwei Zhou, Yang Zheng, Qiao Yan, Gaowu Liao, Hongfan Du, Silin Zhang, Xiaohui Lv, Fajin Zhang, Zhiwei Li, Yong-mei Insights Imaging Original Article OBJECTIVES: To evaluate the value of monoenergetic images (MEI [+]) and iodine maps in dual-source dual-energy computed tomography (DECT) for assessing pancreatic ductal adenocarcinoma (PDAC), including the visually isoattenuating PDAC. MATERIALS AND METHODS: This retrospective study included 75 PDAC patients, who underwent contrast-enhanced DECT examinations. Conventional polyenergetic image (PEI) and 40–80 keV MEI (+) (10-keV increments) were reconstructed. The tumor contrast, contrast-to-noise ratio (CNR) of the tumor and peripancreatic vessels, the signal-to-noise ratio (SNR) of the pancreas and tumor, and the tumor diameters were quantified. On iodine maps, the normalized iodine concentration (NIC) in the tumor and parenchyma was compared. For subjective analysis, two radiologists independently evaluated images on a 5-point scale. RESULTS: All the quantitative parameters were maximized at 40-keV MEI (+) and decreased gradually with increasing energy. The tumor contrast, SNR of pancreas and CNRs in 40–60 keV MEI (+) were significantly higher than those in PEI (p < 0.05). For visually isoattenuating PDAC, 40–50 keV MEI (+) provided significantly higher tumor CNR compared to PEI (p < 0.05). The reproducibility in tumor measurements was highest in 40-keV MEI (+) between the two radiologists. The tumor and parenchyma NIC were 1.28 ± 0.65 and 3.38 ± 0.72 mg/mL, respectively (p < 0.001). 40–50 keV MEI (+) provided the highest subjective scores, compared to PEI (p < 0.001). CONCLUSIONS: Low-keV MEI (+) of DECT substantially improves the subjective and objective image quality and consistency of tumor measurements in patients with PDAC. Combining the low-keV MEI (+) and iodine maps may yield diagnostically adequate tumor conspicuity in visually isoattenuating PDAC. Springer Vienna 2022-09-24 /pmc/articles/PMC9509509/ /pubmed/36153376 http://dx.doi.org/10.1186/s13244-022-01297-2 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Liang, Hongwei
Zhou, Yang
Zheng, Qiao
Yan, Gaowu
Liao, Hongfan
Du, Silin
Zhang, Xiaohui
Lv, Fajin
Zhang, Zhiwei
Li, Yong-mei
Dual-energy CT with virtual monoenergetic images and iodine maps improves tumor conspicuity in patients with pancreatic ductal adenocarcinoma
title Dual-energy CT with virtual monoenergetic images and iodine maps improves tumor conspicuity in patients with pancreatic ductal adenocarcinoma
title_full Dual-energy CT with virtual monoenergetic images and iodine maps improves tumor conspicuity in patients with pancreatic ductal adenocarcinoma
title_fullStr Dual-energy CT with virtual monoenergetic images and iodine maps improves tumor conspicuity in patients with pancreatic ductal adenocarcinoma
title_full_unstemmed Dual-energy CT with virtual monoenergetic images and iodine maps improves tumor conspicuity in patients with pancreatic ductal adenocarcinoma
title_short Dual-energy CT with virtual monoenergetic images and iodine maps improves tumor conspicuity in patients with pancreatic ductal adenocarcinoma
title_sort dual-energy ct with virtual monoenergetic images and iodine maps improves tumor conspicuity in patients with pancreatic ductal adenocarcinoma
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9509509/
https://www.ncbi.nlm.nih.gov/pubmed/36153376
http://dx.doi.org/10.1186/s13244-022-01297-2
work_keys_str_mv AT lianghongwei dualenergyctwithvirtualmonoenergeticimagesandiodinemapsimprovestumorconspicuityinpatientswithpancreaticductaladenocarcinoma
AT zhouyang dualenergyctwithvirtualmonoenergeticimagesandiodinemapsimprovestumorconspicuityinpatientswithpancreaticductaladenocarcinoma
AT zhengqiao dualenergyctwithvirtualmonoenergeticimagesandiodinemapsimprovestumorconspicuityinpatientswithpancreaticductaladenocarcinoma
AT yangaowu dualenergyctwithvirtualmonoenergeticimagesandiodinemapsimprovestumorconspicuityinpatientswithpancreaticductaladenocarcinoma
AT liaohongfan dualenergyctwithvirtualmonoenergeticimagesandiodinemapsimprovestumorconspicuityinpatientswithpancreaticductaladenocarcinoma
AT dusilin dualenergyctwithvirtualmonoenergeticimagesandiodinemapsimprovestumorconspicuityinpatientswithpancreaticductaladenocarcinoma
AT zhangxiaohui dualenergyctwithvirtualmonoenergeticimagesandiodinemapsimprovestumorconspicuityinpatientswithpancreaticductaladenocarcinoma
AT lvfajin dualenergyctwithvirtualmonoenergeticimagesandiodinemapsimprovestumorconspicuityinpatientswithpancreaticductaladenocarcinoma
AT zhangzhiwei dualenergyctwithvirtualmonoenergeticimagesandiodinemapsimprovestumorconspicuityinpatientswithpancreaticductaladenocarcinoma
AT liyongmei dualenergyctwithvirtualmonoenergeticimagesandiodinemapsimprovestumorconspicuityinpatientswithpancreaticductaladenocarcinoma