O-pH: Optical pH Monitor to Measure Dental Biofilm Acidity and Assist in Enamel Health Monitoring

OBJECTIVE: Bacteria in the dental biofilm produceacid after consumption of carbohydrates which if left unmonitored leads to caries formation. We present O-pH, a device that can measure dental biofilm acidity and provide quantitative feedback to assist in oral health monitoring. METHOD: O-pH utilizes...

Descripción completa

Detalles Bibliográficos
Autores principales: Sharma, Manuja, Lee, Lauren K., Carson, Matthew D., Park, David S., An, Se W., Bovenkamp, Micah G., Cayetano, Jess J., Berude, Ian A., Nelson, Leonard Y., Xu, Zheng, Sadr, Alireza, Patel, Shwetak N., Seibel, Eric J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9509691/
https://www.ncbi.nlm.nih.gov/pubmed/35196222
http://dx.doi.org/10.1109/TBME.2022.3153659
_version_ 1784797283272884224
author Sharma, Manuja
Lee, Lauren K.
Carson, Matthew D.
Park, David S.
An, Se W.
Bovenkamp, Micah G.
Cayetano, Jess J.
Berude, Ian A.
Nelson, Leonard Y.
Xu, Zheng
Sadr, Alireza
Patel, Shwetak N.
Seibel, Eric J.
author_facet Sharma, Manuja
Lee, Lauren K.
Carson, Matthew D.
Park, David S.
An, Se W.
Bovenkamp, Micah G.
Cayetano, Jess J.
Berude, Ian A.
Nelson, Leonard Y.
Xu, Zheng
Sadr, Alireza
Patel, Shwetak N.
Seibel, Eric J.
author_sort Sharma, Manuja
collection PubMed
description OBJECTIVE: Bacteria in the dental biofilm produceacid after consumption of carbohydrates which if left unmonitored leads to caries formation. We present O-pH, a device that can measure dental biofilm acidity and provide quantitative feedback to assist in oral health monitoring. METHOD: O-pH utilizes a ratiometric pH sensing method by capturing fluorescence of Sodium Fluorescein, an FDA approved chemical dye. The device was calibrated to a lab pH meter using buffered fluorescein solution with a correlation coefficient of 0.97. The calibration was further verified in vitro on additional buffered solution, artificial, and extracted teeth. An in vivo study on 30 pediatric subjects was performed to measure pH before (rest pH) and after (drop pH) a sugar rinse, and the resultant difference in pH (diff pH) was calculated. The study enrolled subjects with low (Post-Cleaning) and heavy (Pre-Cleaning) biofilm load, having both unhealthy/healthy surfaces. Further, we modified point-based O-pH to an image-based device using a multimode-scanning fiber endoscope (mm-SFE) and tested in vivo on one subject. RESULTS AND CONCLUSION: We found significant difference between Post-Cleaning and Pre-Cleaning group using drop pH and diff pH. Additionally, in Pre-Cleaning group, the rest and drop pH is lower at the caries surfaces compared to healthy surfaces. Similar trend was not noticed in the Post-Cleaning group. mm-SFE pH scope recorded image-based pH heatmap of a subject with an average diff pH of 1.5. SIGNIFICANCE: This work builds an optical pH prototype and presents a pioneering study for non-invasively measuring pH of dental biofilm clinically.
format Online
Article
Text
id pubmed-9509691
institution National Center for Biotechnology Information
language English
publishDate 2022
record_format MEDLINE/PubMed
spelling pubmed-95096912022-09-25 O-pH: Optical pH Monitor to Measure Dental Biofilm Acidity and Assist in Enamel Health Monitoring Sharma, Manuja Lee, Lauren K. Carson, Matthew D. Park, David S. An, Se W. Bovenkamp, Micah G. Cayetano, Jess J. Berude, Ian A. Nelson, Leonard Y. Xu, Zheng Sadr, Alireza Patel, Shwetak N. Seibel, Eric J. IEEE Trans Biomed Eng Article OBJECTIVE: Bacteria in the dental biofilm produceacid after consumption of carbohydrates which if left unmonitored leads to caries formation. We present O-pH, a device that can measure dental biofilm acidity and provide quantitative feedback to assist in oral health monitoring. METHOD: O-pH utilizes a ratiometric pH sensing method by capturing fluorescence of Sodium Fluorescein, an FDA approved chemical dye. The device was calibrated to a lab pH meter using buffered fluorescein solution with a correlation coefficient of 0.97. The calibration was further verified in vitro on additional buffered solution, artificial, and extracted teeth. An in vivo study on 30 pediatric subjects was performed to measure pH before (rest pH) and after (drop pH) a sugar rinse, and the resultant difference in pH (diff pH) was calculated. The study enrolled subjects with low (Post-Cleaning) and heavy (Pre-Cleaning) biofilm load, having both unhealthy/healthy surfaces. Further, we modified point-based O-pH to an image-based device using a multimode-scanning fiber endoscope (mm-SFE) and tested in vivo on one subject. RESULTS AND CONCLUSION: We found significant difference between Post-Cleaning and Pre-Cleaning group using drop pH and diff pH. Additionally, in Pre-Cleaning group, the rest and drop pH is lower at the caries surfaces compared to healthy surfaces. Similar trend was not noticed in the Post-Cleaning group. mm-SFE pH scope recorded image-based pH heatmap of a subject with an average diff pH of 1.5. SIGNIFICANCE: This work builds an optical pH prototype and presents a pioneering study for non-invasively measuring pH of dental biofilm clinically. 2022-09 2022-08-19 /pmc/articles/PMC9509691/ /pubmed/35196222 http://dx.doi.org/10.1109/TBME.2022.3153659 Text en https://creativecommons.org/licenses/by/4.0/This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see https://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Sharma, Manuja
Lee, Lauren K.
Carson, Matthew D.
Park, David S.
An, Se W.
Bovenkamp, Micah G.
Cayetano, Jess J.
Berude, Ian A.
Nelson, Leonard Y.
Xu, Zheng
Sadr, Alireza
Patel, Shwetak N.
Seibel, Eric J.
O-pH: Optical pH Monitor to Measure Dental Biofilm Acidity and Assist in Enamel Health Monitoring
title O-pH: Optical pH Monitor to Measure Dental Biofilm Acidity and Assist in Enamel Health Monitoring
title_full O-pH: Optical pH Monitor to Measure Dental Biofilm Acidity and Assist in Enamel Health Monitoring
title_fullStr O-pH: Optical pH Monitor to Measure Dental Biofilm Acidity and Assist in Enamel Health Monitoring
title_full_unstemmed O-pH: Optical pH Monitor to Measure Dental Biofilm Acidity and Assist in Enamel Health Monitoring
title_short O-pH: Optical pH Monitor to Measure Dental Biofilm Acidity and Assist in Enamel Health Monitoring
title_sort o-ph: optical ph monitor to measure dental biofilm acidity and assist in enamel health monitoring
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9509691/
https://www.ncbi.nlm.nih.gov/pubmed/35196222
http://dx.doi.org/10.1109/TBME.2022.3153659
work_keys_str_mv AT sharmamanuja ophopticalphmonitortomeasuredentalbiofilmacidityandassistinenamelhealthmonitoring
AT leelaurenk ophopticalphmonitortomeasuredentalbiofilmacidityandassistinenamelhealthmonitoring
AT carsonmatthewd ophopticalphmonitortomeasuredentalbiofilmacidityandassistinenamelhealthmonitoring
AT parkdavids ophopticalphmonitortomeasuredentalbiofilmacidityandassistinenamelhealthmonitoring
AT ansew ophopticalphmonitortomeasuredentalbiofilmacidityandassistinenamelhealthmonitoring
AT bovenkampmicahg ophopticalphmonitortomeasuredentalbiofilmacidityandassistinenamelhealthmonitoring
AT cayetanojessj ophopticalphmonitortomeasuredentalbiofilmacidityandassistinenamelhealthmonitoring
AT berudeiana ophopticalphmonitortomeasuredentalbiofilmacidityandassistinenamelhealthmonitoring
AT nelsonleonardy ophopticalphmonitortomeasuredentalbiofilmacidityandassistinenamelhealthmonitoring
AT xuzheng ophopticalphmonitortomeasuredentalbiofilmacidityandassistinenamelhealthmonitoring
AT sadralireza ophopticalphmonitortomeasuredentalbiofilmacidityandassistinenamelhealthmonitoring
AT patelshwetakn ophopticalphmonitortomeasuredentalbiofilmacidityandassistinenamelhealthmonitoring
AT seibelericj ophopticalphmonitortomeasuredentalbiofilmacidityandassistinenamelhealthmonitoring