Cargando…

Advanced cutting strategy for navigated, robot-driven laser craniotomy for stereoelectroencephalography: An in Vivo non-recovery animal study

Objectives: In this study we aimed to present an updated cutting strategy and updated hardware for a new camera system that can increase cut-through detection using a cold ablation robot-guided laser osteotome. Methods: We performed a preoperative computed tomography scan of each animal. The laser w...

Descripción completa

Detalles Bibliográficos
Autores principales: Winter, Fabian, Beer, Daniel, Gono, Patrick, Medagli, Stefano, Morawska, Marta, Dorfer, Christian, Roessler, Karl
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9510662/
https://www.ncbi.nlm.nih.gov/pubmed/36172304
http://dx.doi.org/10.3389/frobt.2022.997413
_version_ 1784797485947944960
author Winter, Fabian
Beer, Daniel
Gono, Patrick
Medagli, Stefano
Morawska, Marta
Dorfer, Christian
Roessler, Karl
author_facet Winter, Fabian
Beer, Daniel
Gono, Patrick
Medagli, Stefano
Morawska, Marta
Dorfer, Christian
Roessler, Karl
author_sort Winter, Fabian
collection PubMed
description Objectives: In this study we aimed to present an updated cutting strategy and updated hardware for a new camera system that can increase cut-through detection using a cold ablation robot-guided laser osteotome. Methods: We performed a preoperative computed tomography scan of each animal. The laser was mounted on a robotic arm and guided by a navigation system based on a tracking camera. Surgery was performed with animals in the prone position. A new cutting strategy was implemented consisting of two circular paths involving inner (full cylindric) and outer (hollow cylindric) sections, with three different ablation phases. The depth electrodes were inserted after cut-through detection was confirmed on either the coaxial camera system or optical coherence tomography signal. Results: A total of 71 precision bone channels were cut in four pig specimens using a robot-guided laser. No signs of hemodynamic or respiratory irregularities were observed during anesthesia. All bone channels were created using the advanced cutting strategy. The new cutting strategy showed no irregularities in either cylindrical (parallel walled; n = 38, 45° = 10, 60° = 14, 90° = 14) or anticonical (walls widening by 2 degrees; n = 33, 45° = 11, 60° = 13, 90° = 9) bone channels. The entrance hole diameters ranged from 2.25–3.7 mm and the exit hole diameters ranged from 1.25 to 2.82 mm. Anchor bolts were successfully inserted in all bone channels. No unintended damage to the cortex was detected after laser guided craniotomy. Conclusion: The new cutting strategy showed promising results in more than 70 precision angulated cylindrical and anti-conical bone channels in this large, in vivo non-recovery animal study. Our findings indicate that the coaxial camera system is feasible for cut-through detection.
format Online
Article
Text
id pubmed-9510662
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-95106622022-09-27 Advanced cutting strategy for navigated, robot-driven laser craniotomy for stereoelectroencephalography: An in Vivo non-recovery animal study Winter, Fabian Beer, Daniel Gono, Patrick Medagli, Stefano Morawska, Marta Dorfer, Christian Roessler, Karl Front Robot AI Robotics and AI Objectives: In this study we aimed to present an updated cutting strategy and updated hardware for a new camera system that can increase cut-through detection using a cold ablation robot-guided laser osteotome. Methods: We performed a preoperative computed tomography scan of each animal. The laser was mounted on a robotic arm and guided by a navigation system based on a tracking camera. Surgery was performed with animals in the prone position. A new cutting strategy was implemented consisting of two circular paths involving inner (full cylindric) and outer (hollow cylindric) sections, with three different ablation phases. The depth electrodes were inserted after cut-through detection was confirmed on either the coaxial camera system or optical coherence tomography signal. Results: A total of 71 precision bone channels were cut in four pig specimens using a robot-guided laser. No signs of hemodynamic or respiratory irregularities were observed during anesthesia. All bone channels were created using the advanced cutting strategy. The new cutting strategy showed no irregularities in either cylindrical (parallel walled; n = 38, 45° = 10, 60° = 14, 90° = 14) or anticonical (walls widening by 2 degrees; n = 33, 45° = 11, 60° = 13, 90° = 9) bone channels. The entrance hole diameters ranged from 2.25–3.7 mm and the exit hole diameters ranged from 1.25 to 2.82 mm. Anchor bolts were successfully inserted in all bone channels. No unintended damage to the cortex was detected after laser guided craniotomy. Conclusion: The new cutting strategy showed promising results in more than 70 precision angulated cylindrical and anti-conical bone channels in this large, in vivo non-recovery animal study. Our findings indicate that the coaxial camera system is feasible for cut-through detection. Frontiers Media S.A. 2022-09-12 /pmc/articles/PMC9510662/ /pubmed/36172304 http://dx.doi.org/10.3389/frobt.2022.997413 Text en Copyright © 2022 Winter, Beer, Gono, Medagli, Morawska, Dorfer and Roessler. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Robotics and AI
Winter, Fabian
Beer, Daniel
Gono, Patrick
Medagli, Stefano
Morawska, Marta
Dorfer, Christian
Roessler, Karl
Advanced cutting strategy for navigated, robot-driven laser craniotomy for stereoelectroencephalography: An in Vivo non-recovery animal study
title Advanced cutting strategy for navigated, robot-driven laser craniotomy for stereoelectroencephalography: An in Vivo non-recovery animal study
title_full Advanced cutting strategy for navigated, robot-driven laser craniotomy for stereoelectroencephalography: An in Vivo non-recovery animal study
title_fullStr Advanced cutting strategy for navigated, robot-driven laser craniotomy for stereoelectroencephalography: An in Vivo non-recovery animal study
title_full_unstemmed Advanced cutting strategy for navigated, robot-driven laser craniotomy for stereoelectroencephalography: An in Vivo non-recovery animal study
title_short Advanced cutting strategy for navigated, robot-driven laser craniotomy for stereoelectroencephalography: An in Vivo non-recovery animal study
title_sort advanced cutting strategy for navigated, robot-driven laser craniotomy for stereoelectroencephalography: an in vivo non-recovery animal study
topic Robotics and AI
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9510662/
https://www.ncbi.nlm.nih.gov/pubmed/36172304
http://dx.doi.org/10.3389/frobt.2022.997413
work_keys_str_mv AT winterfabian advancedcuttingstrategyfornavigatedrobotdrivenlasercraniotomyforstereoelectroencephalographyaninvivononrecoveryanimalstudy
AT beerdaniel advancedcuttingstrategyfornavigatedrobotdrivenlasercraniotomyforstereoelectroencephalographyaninvivononrecoveryanimalstudy
AT gonopatrick advancedcuttingstrategyfornavigatedrobotdrivenlasercraniotomyforstereoelectroencephalographyaninvivononrecoveryanimalstudy
AT medaglistefano advancedcuttingstrategyfornavigatedrobotdrivenlasercraniotomyforstereoelectroencephalographyaninvivononrecoveryanimalstudy
AT morawskamarta advancedcuttingstrategyfornavigatedrobotdrivenlasercraniotomyforstereoelectroencephalographyaninvivononrecoveryanimalstudy
AT dorferchristian advancedcuttingstrategyfornavigatedrobotdrivenlasercraniotomyforstereoelectroencephalographyaninvivononrecoveryanimalstudy
AT roesslerkarl advancedcuttingstrategyfornavigatedrobotdrivenlasercraniotomyforstereoelectroencephalographyaninvivononrecoveryanimalstudy