Cargando…

Evaluation of the performance of two new generation pulse oximeters in cats at different probe positions and under the influence of vasoconstriction

OBJECTIVES: The aim of this study was to compare the failure rate of two new generation pulse oximeters at different probe positions, and with and without vasoconstriction, in anaesthetised cats. METHODS: This prospective clinical study included 103 cats in which the new generation pulse oximeters,...

Descripción completa

Detalles Bibliográficos
Autores principales: Dörfelt, René, Diels, Julia, Hartmann, Katrin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9510937/
https://www.ncbi.nlm.nih.gov/pubmed/34904479
http://dx.doi.org/10.1177/1098612X211063768
Descripción
Sumario:OBJECTIVES: The aim of this study was to compare the failure rate of two new generation pulse oximeters at different probe positions, and with and without vasoconstriction, in anaesthetised cats. METHODS: This prospective clinical study included 103 cats in which the new generation pulse oximeters, the Rad-5 (Masimo) and EDAN H100N (EDAN), were evaluated. Premedication consisted of the vasoconstrictive drug combination butorphanol (0.2 mg/kg IV) and dexmedetomidine (5 µg/kg IV), or butorphanol only (0.2 mg/kg IV). Pulse oximeter failure rate at the tongue was compared between both groups. Pulse oximeter failure rate was also analysed at the alternative probe positions of the lip, pinna, knee fold and toe in the butorphanol group. Student’s t-test, Wilcoxon matched pairs signed rank test, Mann−Whitney U-test, Friedman test and χ(2) test were performed. A P value <0.05 was considered to be statistically significant. RESULTS: Overall failure to achieve an adequate signal was 37.6% with the Masimo and 48.0% with the EDAN pulse oximeter (P <0.0001). At the standard probe position on the tongue, the Masimo failed in 4.5%, while the EDAN failed in 35.3% (P <0.0001). Vasoactive premedication increased the failure rate for the Masimo from 3.8% to 5.2% (P = 0.3414) and for the EDAN from 22.4% to 49.0% (P <0.0001). At the alternative probe positions of the lip and knee fold, failure rates for the Masimo were lower (39.7% and 81.4%) than with the EDAN (52.6% and 94.4%; P = 0.0231 and P = 0.0005, respectively), while the Masimo failed more often at the pinna (63.5%) than the EDAN (47.4%; P = 0.0044). At the alternative probe position of the toe, the failure rate for the Masimo (32.7%) was not different from the EDAN (38.5%; P = 0.7547). CONCLUSIONS AND RELEVANCE: The Masimo pulse oximeter had lower signal failure rates at the standard probe position on the tongue and at 2/4 alternative probe positions. The standard probe position on the tongue had the lowest failure rate for both devices. Dexmedetomidine-induced vasoconstriction increased the failure rate for the EDAN but not for the Masimo pulse oximeter.