Cargando…

Algorithm for real-time analysis of intracoronary electrocardiogram

INTRODUCTION: Since its first implementation in 1985, intracoronary (ic) electrocardiogram (ECG) has shown ample evidence for its diagnostic value given the higher sensitivity for myocardial ischemia detection in comparison to surface ECG. However, a lack of online systems to quantitatively analyze...

Descripción completa

Detalles Bibliográficos
Autores principales: Bigler, Marius Reto, Kieninger-Gräfitsch, Andrea, Waldmann, Frédéric, Seiler, Christian, Wildhaber, Reto
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9512037/
https://www.ncbi.nlm.nih.gov/pubmed/36172580
http://dx.doi.org/10.3389/fcvm.2022.930717
_version_ 1784797769271083008
author Bigler, Marius Reto
Kieninger-Gräfitsch, Andrea
Waldmann, Frédéric
Seiler, Christian
Wildhaber, Reto
author_facet Bigler, Marius Reto
Kieninger-Gräfitsch, Andrea
Waldmann, Frédéric
Seiler, Christian
Wildhaber, Reto
author_sort Bigler, Marius Reto
collection PubMed
description INTRODUCTION: Since its first implementation in 1985, intracoronary (ic) electrocardiogram (ECG) has shown ample evidence for its diagnostic value given the higher sensitivity for myocardial ischemia detection in comparison to surface ECG. However, a lack of online systems to quantitatively analyze icECG in real-time prevents its routine use. The present study aimed to develop and validate an autonomous icECG analyzing algorithm. MATERIALS AND METHODS: This is a retrospective observational study in 100 patients with chronic coronary syndrome. From each patient, a non-ischemic as well as ischemic icECG at the end of a 1-min proximal coronary balloon occlusion was available. An ECG expert as well as the newly developed algorithm for autonomous icECG analysis measured the icECG ST-segment shift in mV for each icECG tracing. RESULTS: Intraclass correlation coefficient (ICC) demonstrated low variability between the two methods (ICC = 0.968). Using the time point of icECG recording as allocation reference for absent or present myocardial ischemia, ROC-analysis for ischemia detection by the manually determined icECG ST-segment shift showed an area under the curve (AUC) of 0.968 ± 0.021 (p < 0.0001). AUC for the algorithm analysis was 0.967 ± 0.023 (p < 0.0001; p = 0.925 for the difference between the ROC curve AUCs). Time to complete analysis was below 1,000 ms for the autonomous icECG analysis and above 5 min for manual analysis. CONCLUSION: A newly developed autonomous icECG analysing algorithm detects myocardial ischemia with equal accuracy as manual ST-segment shift assessment. The algorithm provides the technical fundament for an analysing system to quantitatively obtain icECG in real-time.
format Online
Article
Text
id pubmed-9512037
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-95120372022-09-27 Algorithm for real-time analysis of intracoronary electrocardiogram Bigler, Marius Reto Kieninger-Gräfitsch, Andrea Waldmann, Frédéric Seiler, Christian Wildhaber, Reto Front Cardiovasc Med Cardiovascular Medicine INTRODUCTION: Since its first implementation in 1985, intracoronary (ic) electrocardiogram (ECG) has shown ample evidence for its diagnostic value given the higher sensitivity for myocardial ischemia detection in comparison to surface ECG. However, a lack of online systems to quantitatively analyze icECG in real-time prevents its routine use. The present study aimed to develop and validate an autonomous icECG analyzing algorithm. MATERIALS AND METHODS: This is a retrospective observational study in 100 patients with chronic coronary syndrome. From each patient, a non-ischemic as well as ischemic icECG at the end of a 1-min proximal coronary balloon occlusion was available. An ECG expert as well as the newly developed algorithm for autonomous icECG analysis measured the icECG ST-segment shift in mV for each icECG tracing. RESULTS: Intraclass correlation coefficient (ICC) demonstrated low variability between the two methods (ICC = 0.968). Using the time point of icECG recording as allocation reference for absent or present myocardial ischemia, ROC-analysis for ischemia detection by the manually determined icECG ST-segment shift showed an area under the curve (AUC) of 0.968 ± 0.021 (p < 0.0001). AUC for the algorithm analysis was 0.967 ± 0.023 (p < 0.0001; p = 0.925 for the difference between the ROC curve AUCs). Time to complete analysis was below 1,000 ms for the autonomous icECG analysis and above 5 min for manual analysis. CONCLUSION: A newly developed autonomous icECG analysing algorithm detects myocardial ischemia with equal accuracy as manual ST-segment shift assessment. The algorithm provides the technical fundament for an analysing system to quantitatively obtain icECG in real-time. Frontiers Media S.A. 2022-09-07 /pmc/articles/PMC9512037/ /pubmed/36172580 http://dx.doi.org/10.3389/fcvm.2022.930717 Text en Copyright © 2022 Bigler, Kieninger-Gräfitsch, Waldmann, Seiler and Wildhaber. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Cardiovascular Medicine
Bigler, Marius Reto
Kieninger-Gräfitsch, Andrea
Waldmann, Frédéric
Seiler, Christian
Wildhaber, Reto
Algorithm for real-time analysis of intracoronary electrocardiogram
title Algorithm for real-time analysis of intracoronary electrocardiogram
title_full Algorithm for real-time analysis of intracoronary electrocardiogram
title_fullStr Algorithm for real-time analysis of intracoronary electrocardiogram
title_full_unstemmed Algorithm for real-time analysis of intracoronary electrocardiogram
title_short Algorithm for real-time analysis of intracoronary electrocardiogram
title_sort algorithm for real-time analysis of intracoronary electrocardiogram
topic Cardiovascular Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9512037/
https://www.ncbi.nlm.nih.gov/pubmed/36172580
http://dx.doi.org/10.3389/fcvm.2022.930717
work_keys_str_mv AT biglermariusreto algorithmforrealtimeanalysisofintracoronaryelectrocardiogram
AT kieningergrafitschandrea algorithmforrealtimeanalysisofintracoronaryelectrocardiogram
AT waldmannfrederic algorithmforrealtimeanalysisofintracoronaryelectrocardiogram
AT seilerchristian algorithmforrealtimeanalysisofintracoronaryelectrocardiogram
AT wildhaberreto algorithmforrealtimeanalysisofintracoronaryelectrocardiogram