Detection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary?

PURPOSE: Recently the use of linear accelerator (linac)‐based stereotactic radiosurgery (SRS) has increased, including single‐isocenter multiple‐target SRS. The workload of medical physicists has grown as a result and so has the necessity of maximizing the efficiency of quality assurance (QA). This...

Descripción completa

Detalles Bibliográficos
Autores principales: Pudsey, Lauren M. M., Biasi, Giordano, Ralston, Anna, Rosenfeld, Anatoly, Poder, Joel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9512335/
https://www.ncbi.nlm.nih.gov/pubmed/35713881
http://dx.doi.org/10.1002/acm2.13665
_version_ 1784797827563520000
author Pudsey, Lauren M. M.
Biasi, Giordano
Ralston, Anna
Rosenfeld, Anatoly
Poder, Joel
author_facet Pudsey, Lauren M. M.
Biasi, Giordano
Ralston, Anna
Rosenfeld, Anatoly
Poder, Joel
author_sort Pudsey, Lauren M. M.
collection PubMed
description PURPOSE: Recently the use of linear accelerator (linac)‐based stereotactic radiosurgery (SRS) has increased, including single‐isocenter multiple‐target SRS. The workload of medical physicists has grown as a result and so has the necessity of maximizing the efficiency of quality assurance (QA). This study aimed to determine if measurement‐based patient‐specific QA with a high‐spatial‐resolution dosimeter is sensitive to rotational errors, potentially reducing the need for routine off‐axis Winston–Lutz (WL) testing. METHODS: The impact of rotational errors along gantry, couch, and collimator axes on dose coverage of the gross tumor volume (GTV) and planning target volume (PTV) was determined with a 1‐mm GTV/PTV expansion margin. Two techniques, the off‐axis WL test using the StereoPHAN MultiMet‐WL Cube (Sun Nuclear Corporation, Melbourne, Florida, USA) and patient‐specific QA using the SRS MapCHECK (Sun Nuclear Corporation, Melbourne, Florida, USA), were assessed on their ability to detect introduced errors before target coverage was compromised. These findings were also considered in the context of routine machine QA of rotational axis calibrations. RESULTS: Rotational errors significantly impacted PTV dose coverage, especially in the couch angle. GTV dose coverage remained unaffected except for with large couch angle errors (≥1.5°). The off‐axis WL test was shown to be sensitive to rotational errors with results consistently exceeding tolerance levels when or before coverage fell below departmentally accepted limits. Although patient‐specific QA using the SRS MapCHECK was previously validated for SRS, this study showed inconsistency in detection of rotational errors. CONCLUSIONS: It is recommended that off‐axis WL testing be conducted regularly to supplement routine monthly machine QA, as it is sensitive to errors that patient‐specific QA may not detect. This frequency should be determined by individual departments, with consideration of GTV–PTV margins used, limitations on target off‐axis distances, and routine mechanical QA results for particular linacs.
format Online
Article
Text
id pubmed-9512335
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-95123352022-09-30 Detection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary? Pudsey, Lauren M. M. Biasi, Giordano Ralston, Anna Rosenfeld, Anatoly Poder, Joel J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: Recently the use of linear accelerator (linac)‐based stereotactic radiosurgery (SRS) has increased, including single‐isocenter multiple‐target SRS. The workload of medical physicists has grown as a result and so has the necessity of maximizing the efficiency of quality assurance (QA). This study aimed to determine if measurement‐based patient‐specific QA with a high‐spatial‐resolution dosimeter is sensitive to rotational errors, potentially reducing the need for routine off‐axis Winston–Lutz (WL) testing. METHODS: The impact of rotational errors along gantry, couch, and collimator axes on dose coverage of the gross tumor volume (GTV) and planning target volume (PTV) was determined with a 1‐mm GTV/PTV expansion margin. Two techniques, the off‐axis WL test using the StereoPHAN MultiMet‐WL Cube (Sun Nuclear Corporation, Melbourne, Florida, USA) and patient‐specific QA using the SRS MapCHECK (Sun Nuclear Corporation, Melbourne, Florida, USA), were assessed on their ability to detect introduced errors before target coverage was compromised. These findings were also considered in the context of routine machine QA of rotational axis calibrations. RESULTS: Rotational errors significantly impacted PTV dose coverage, especially in the couch angle. GTV dose coverage remained unaffected except for with large couch angle errors (≥1.5°). The off‐axis WL test was shown to be sensitive to rotational errors with results consistently exceeding tolerance levels when or before coverage fell below departmentally accepted limits. Although patient‐specific QA using the SRS MapCHECK was previously validated for SRS, this study showed inconsistency in detection of rotational errors. CONCLUSIONS: It is recommended that off‐axis WL testing be conducted regularly to supplement routine monthly machine QA, as it is sensitive to errors that patient‐specific QA may not detect. This frequency should be determined by individual departments, with consideration of GTV–PTV margins used, limitations on target off‐axis distances, and routine mechanical QA results for particular linacs. John Wiley and Sons Inc. 2022-06-17 /pmc/articles/PMC9512335/ /pubmed/35713881 http://dx.doi.org/10.1002/acm2.13665 Text en © 2022 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Pudsey, Lauren M. M.
Biasi, Giordano
Ralston, Anna
Rosenfeld, Anatoly
Poder, Joel
Detection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary?
title Detection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary?
title_full Detection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary?
title_fullStr Detection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary?
title_full_unstemmed Detection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary?
title_short Detection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary?
title_sort detection of rotational errors in single‐isocenter multiple‐target radiosurgery: is a routine off‐axis winston–lutz test necessary?
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9512335/
https://www.ncbi.nlm.nih.gov/pubmed/35713881
http://dx.doi.org/10.1002/acm2.13665
work_keys_str_mv AT pudseylaurenmm detectionofrotationalerrorsinsingleisocentermultipletargetradiosurgeryisaroutineoffaxiswinstonlutztestnecessary
AT biasigiordano detectionofrotationalerrorsinsingleisocentermultipletargetradiosurgeryisaroutineoffaxiswinstonlutztestnecessary
AT ralstonanna detectionofrotationalerrorsinsingleisocentermultipletargetradiosurgeryisaroutineoffaxiswinstonlutztestnecessary
AT rosenfeldanatoly detectionofrotationalerrorsinsingleisocentermultipletargetradiosurgeryisaroutineoffaxiswinstonlutztestnecessary
AT poderjoel detectionofrotationalerrorsinsingleisocentermultipletargetradiosurgeryisaroutineoffaxiswinstonlutztestnecessary