Detection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary?
PURPOSE: Recently the use of linear accelerator (linac)‐based stereotactic radiosurgery (SRS) has increased, including single‐isocenter multiple‐target SRS. The workload of medical physicists has grown as a result and so has the necessity of maximizing the efficiency of quality assurance (QA). This...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9512335/ https://www.ncbi.nlm.nih.gov/pubmed/35713881 http://dx.doi.org/10.1002/acm2.13665 |
_version_ | 1784797827563520000 |
---|---|
author | Pudsey, Lauren M. M. Biasi, Giordano Ralston, Anna Rosenfeld, Anatoly Poder, Joel |
author_facet | Pudsey, Lauren M. M. Biasi, Giordano Ralston, Anna Rosenfeld, Anatoly Poder, Joel |
author_sort | Pudsey, Lauren M. M. |
collection | PubMed |
description | PURPOSE: Recently the use of linear accelerator (linac)‐based stereotactic radiosurgery (SRS) has increased, including single‐isocenter multiple‐target SRS. The workload of medical physicists has grown as a result and so has the necessity of maximizing the efficiency of quality assurance (QA). This study aimed to determine if measurement‐based patient‐specific QA with a high‐spatial‐resolution dosimeter is sensitive to rotational errors, potentially reducing the need for routine off‐axis Winston–Lutz (WL) testing. METHODS: The impact of rotational errors along gantry, couch, and collimator axes on dose coverage of the gross tumor volume (GTV) and planning target volume (PTV) was determined with a 1‐mm GTV/PTV expansion margin. Two techniques, the off‐axis WL test using the StereoPHAN MultiMet‐WL Cube (Sun Nuclear Corporation, Melbourne, Florida, USA) and patient‐specific QA using the SRS MapCHECK (Sun Nuclear Corporation, Melbourne, Florida, USA), were assessed on their ability to detect introduced errors before target coverage was compromised. These findings were also considered in the context of routine machine QA of rotational axis calibrations. RESULTS: Rotational errors significantly impacted PTV dose coverage, especially in the couch angle. GTV dose coverage remained unaffected except for with large couch angle errors (≥1.5°). The off‐axis WL test was shown to be sensitive to rotational errors with results consistently exceeding tolerance levels when or before coverage fell below departmentally accepted limits. Although patient‐specific QA using the SRS MapCHECK was previously validated for SRS, this study showed inconsistency in detection of rotational errors. CONCLUSIONS: It is recommended that off‐axis WL testing be conducted regularly to supplement routine monthly machine QA, as it is sensitive to errors that patient‐specific QA may not detect. This frequency should be determined by individual departments, with consideration of GTV–PTV margins used, limitations on target off‐axis distances, and routine mechanical QA results for particular linacs. |
format | Online Article Text |
id | pubmed-9512335 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-95123352022-09-30 Detection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary? Pudsey, Lauren M. M. Biasi, Giordano Ralston, Anna Rosenfeld, Anatoly Poder, Joel J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: Recently the use of linear accelerator (linac)‐based stereotactic radiosurgery (SRS) has increased, including single‐isocenter multiple‐target SRS. The workload of medical physicists has grown as a result and so has the necessity of maximizing the efficiency of quality assurance (QA). This study aimed to determine if measurement‐based patient‐specific QA with a high‐spatial‐resolution dosimeter is sensitive to rotational errors, potentially reducing the need for routine off‐axis Winston–Lutz (WL) testing. METHODS: The impact of rotational errors along gantry, couch, and collimator axes on dose coverage of the gross tumor volume (GTV) and planning target volume (PTV) was determined with a 1‐mm GTV/PTV expansion margin. Two techniques, the off‐axis WL test using the StereoPHAN MultiMet‐WL Cube (Sun Nuclear Corporation, Melbourne, Florida, USA) and patient‐specific QA using the SRS MapCHECK (Sun Nuclear Corporation, Melbourne, Florida, USA), were assessed on their ability to detect introduced errors before target coverage was compromised. These findings were also considered in the context of routine machine QA of rotational axis calibrations. RESULTS: Rotational errors significantly impacted PTV dose coverage, especially in the couch angle. GTV dose coverage remained unaffected except for with large couch angle errors (≥1.5°). The off‐axis WL test was shown to be sensitive to rotational errors with results consistently exceeding tolerance levels when or before coverage fell below departmentally accepted limits. Although patient‐specific QA using the SRS MapCHECK was previously validated for SRS, this study showed inconsistency in detection of rotational errors. CONCLUSIONS: It is recommended that off‐axis WL testing be conducted regularly to supplement routine monthly machine QA, as it is sensitive to errors that patient‐specific QA may not detect. This frequency should be determined by individual departments, with consideration of GTV–PTV margins used, limitations on target off‐axis distances, and routine mechanical QA results for particular linacs. John Wiley and Sons Inc. 2022-06-17 /pmc/articles/PMC9512335/ /pubmed/35713881 http://dx.doi.org/10.1002/acm2.13665 Text en © 2022 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Pudsey, Lauren M. M. Biasi, Giordano Ralston, Anna Rosenfeld, Anatoly Poder, Joel Detection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary? |
title | Detection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary? |
title_full | Detection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary? |
title_fullStr | Detection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary? |
title_full_unstemmed | Detection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary? |
title_short | Detection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary? |
title_sort | detection of rotational errors in single‐isocenter multiple‐target radiosurgery: is a routine off‐axis winston–lutz test necessary? |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9512335/ https://www.ncbi.nlm.nih.gov/pubmed/35713881 http://dx.doi.org/10.1002/acm2.13665 |
work_keys_str_mv | AT pudseylaurenmm detectionofrotationalerrorsinsingleisocentermultipletargetradiosurgeryisaroutineoffaxiswinstonlutztestnecessary AT biasigiordano detectionofrotationalerrorsinsingleisocentermultipletargetradiosurgeryisaroutineoffaxiswinstonlutztestnecessary AT ralstonanna detectionofrotationalerrorsinsingleisocentermultipletargetradiosurgeryisaroutineoffaxiswinstonlutztestnecessary AT rosenfeldanatoly detectionofrotationalerrorsinsingleisocentermultipletargetradiosurgeryisaroutineoffaxiswinstonlutztestnecessary AT poderjoel detectionofrotationalerrorsinsingleisocentermultipletargetradiosurgeryisaroutineoffaxiswinstonlutztestnecessary |