Cargando…

Performance of a Qualitative Point-of-Care Strip Test to Detect DOAC Exposure at the Emergency Department: A Cohort-Type Cross-Sectional Diagnostic Accuracy Study

An accurate point-of-care test for detecting effective anticoagulation by direct oral anticoagulants (DOACs) in emergencies is an unmet need. We investigated the accuracy of a urinary qualitative strip test (DOAC Dipstick) to detect relevant DOAC exposure in patients who presented to an emergency de...

Descripción completa

Detalles Bibliográficos
Autores principales: Merrelaar, Anne E., Bögl, Magdalena S., Buchtele, Nina, Merrelaar, Marieke, Herkner, Harald, Schoergenhofer, Christian, Harenberg, Job, Douxfils, Jonathan, Siriez, Romain, Jilma, Bernd, Spiel, Alexander O., Schwameis, Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Georg Thieme Verlag KG 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9512583/
https://www.ncbi.nlm.nih.gov/pubmed/35785816
http://dx.doi.org/10.1055/s-0042-1750327
_version_ 1784797862588055552
author Merrelaar, Anne E.
Bögl, Magdalena S.
Buchtele, Nina
Merrelaar, Marieke
Herkner, Harald
Schoergenhofer, Christian
Harenberg, Job
Douxfils, Jonathan
Siriez, Romain
Jilma, Bernd
Spiel, Alexander O.
Schwameis, Michael
author_facet Merrelaar, Anne E.
Bögl, Magdalena S.
Buchtele, Nina
Merrelaar, Marieke
Herkner, Harald
Schoergenhofer, Christian
Harenberg, Job
Douxfils, Jonathan
Siriez, Romain
Jilma, Bernd
Spiel, Alexander O.
Schwameis, Michael
author_sort Merrelaar, Anne E.
collection PubMed
description An accurate point-of-care test for detecting effective anticoagulation by direct oral anticoagulants (DOACs) in emergencies is an unmet need. We investigated the accuracy of a urinary qualitative strip test (DOAC Dipstick) to detect relevant DOAC exposure in patients who presented to an emergency department. In this prospective single-center cohort-type cross-sectional study, adults on DOAC treatment were enrolled. We assessed clinical sensitivity and specificity of DOAC Dipstick factor Xa and thrombin inhibitor pads to detect DOAC plasma levels ≥30 ng/mL using urine samples as the testing matrix. Liquid chromatography coupled with tandem-mass spectrometry was used as the reference standard method for plasma and urine measurement of DOAC concentrations. Of 293 patients enrolled, 265 patients were included in the analysis, of whom 92 were treated with rivaroxaban, 65 with apixaban, 77 with edoxaban, and 31 with dabigatran. The clinical sensitivity and specificity of the dipstick on urine samples to detect ≥30 ng/mL dabigatran plasma levels were 100% (95% confidence interval [CI]: 87–100%) and 98% (95% CI: 95–99%), respectively. The sensitivity and specificity of the dipstick to detect ≥30 ng/mL factor Xa inhibitor plasma levels were 97% (95% CI: 94–99%) and 69% (95% CI: 56–79%), respectively. The DOAC Dipstick sensitively identified effective thrombin and factor Xa inhibition in a real-world cohort of patients presenting at an emergency department. Therefore, the dipstick might provide a valuable test to detect relevant DOAC exposure in emergencies, although further studies will be needed to confirm these findings.
format Online
Article
Text
id pubmed-9512583
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Georg Thieme Verlag KG
record_format MEDLINE/PubMed
spelling pubmed-95125832022-09-27 Performance of a Qualitative Point-of-Care Strip Test to Detect DOAC Exposure at the Emergency Department: A Cohort-Type Cross-Sectional Diagnostic Accuracy Study Merrelaar, Anne E. Bögl, Magdalena S. Buchtele, Nina Merrelaar, Marieke Herkner, Harald Schoergenhofer, Christian Harenberg, Job Douxfils, Jonathan Siriez, Romain Jilma, Bernd Spiel, Alexander O. Schwameis, Michael Thromb Haemost An accurate point-of-care test for detecting effective anticoagulation by direct oral anticoagulants (DOACs) in emergencies is an unmet need. We investigated the accuracy of a urinary qualitative strip test (DOAC Dipstick) to detect relevant DOAC exposure in patients who presented to an emergency department. In this prospective single-center cohort-type cross-sectional study, adults on DOAC treatment were enrolled. We assessed clinical sensitivity and specificity of DOAC Dipstick factor Xa and thrombin inhibitor pads to detect DOAC plasma levels ≥30 ng/mL using urine samples as the testing matrix. Liquid chromatography coupled with tandem-mass spectrometry was used as the reference standard method for plasma and urine measurement of DOAC concentrations. Of 293 patients enrolled, 265 patients were included in the analysis, of whom 92 were treated with rivaroxaban, 65 with apixaban, 77 with edoxaban, and 31 with dabigatran. The clinical sensitivity and specificity of the dipstick on urine samples to detect ≥30 ng/mL dabigatran plasma levels were 100% (95% confidence interval [CI]: 87–100%) and 98% (95% CI: 95–99%), respectively. The sensitivity and specificity of the dipstick to detect ≥30 ng/mL factor Xa inhibitor plasma levels were 97% (95% CI: 94–99%) and 69% (95% CI: 56–79%), respectively. The DOAC Dipstick sensitively identified effective thrombin and factor Xa inhibition in a real-world cohort of patients presenting at an emergency department. Therefore, the dipstick might provide a valuable test to detect relevant DOAC exposure in emergencies, although further studies will be needed to confirm these findings. Georg Thieme Verlag KG 2022-07-04 /pmc/articles/PMC9512583/ /pubmed/35785816 http://dx.doi.org/10.1055/s-0042-1750327 Text en The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. ( https://creativecommons.org/licenses/by-nc-nd/4.0/ ) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle Merrelaar, Anne E.
Bögl, Magdalena S.
Buchtele, Nina
Merrelaar, Marieke
Herkner, Harald
Schoergenhofer, Christian
Harenberg, Job
Douxfils, Jonathan
Siriez, Romain
Jilma, Bernd
Spiel, Alexander O.
Schwameis, Michael
Performance of a Qualitative Point-of-Care Strip Test to Detect DOAC Exposure at the Emergency Department: A Cohort-Type Cross-Sectional Diagnostic Accuracy Study
title Performance of a Qualitative Point-of-Care Strip Test to Detect DOAC Exposure at the Emergency Department: A Cohort-Type Cross-Sectional Diagnostic Accuracy Study
title_full Performance of a Qualitative Point-of-Care Strip Test to Detect DOAC Exposure at the Emergency Department: A Cohort-Type Cross-Sectional Diagnostic Accuracy Study
title_fullStr Performance of a Qualitative Point-of-Care Strip Test to Detect DOAC Exposure at the Emergency Department: A Cohort-Type Cross-Sectional Diagnostic Accuracy Study
title_full_unstemmed Performance of a Qualitative Point-of-Care Strip Test to Detect DOAC Exposure at the Emergency Department: A Cohort-Type Cross-Sectional Diagnostic Accuracy Study
title_short Performance of a Qualitative Point-of-Care Strip Test to Detect DOAC Exposure at the Emergency Department: A Cohort-Type Cross-Sectional Diagnostic Accuracy Study
title_sort performance of a qualitative point-of-care strip test to detect doac exposure at the emergency department: a cohort-type cross-sectional diagnostic accuracy study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9512583/
https://www.ncbi.nlm.nih.gov/pubmed/35785816
http://dx.doi.org/10.1055/s-0042-1750327
work_keys_str_mv AT merrelaarannee performanceofaqualitativepointofcarestriptesttodetectdoacexposureattheemergencydepartmentacohorttypecrosssectionaldiagnosticaccuracystudy
AT boglmagdalenas performanceofaqualitativepointofcarestriptesttodetectdoacexposureattheemergencydepartmentacohorttypecrosssectionaldiagnosticaccuracystudy
AT buchtelenina performanceofaqualitativepointofcarestriptesttodetectdoacexposureattheemergencydepartmentacohorttypecrosssectionaldiagnosticaccuracystudy
AT merrelaarmarieke performanceofaqualitativepointofcarestriptesttodetectdoacexposureattheemergencydepartmentacohorttypecrosssectionaldiagnosticaccuracystudy
AT herknerharald performanceofaqualitativepointofcarestriptesttodetectdoacexposureattheemergencydepartmentacohorttypecrosssectionaldiagnosticaccuracystudy
AT schoergenhoferchristian performanceofaqualitativepointofcarestriptesttodetectdoacexposureattheemergencydepartmentacohorttypecrosssectionaldiagnosticaccuracystudy
AT harenbergjob performanceofaqualitativepointofcarestriptesttodetectdoacexposureattheemergencydepartmentacohorttypecrosssectionaldiagnosticaccuracystudy
AT douxfilsjonathan performanceofaqualitativepointofcarestriptesttodetectdoacexposureattheemergencydepartmentacohorttypecrosssectionaldiagnosticaccuracystudy
AT siriezromain performanceofaqualitativepointofcarestriptesttodetectdoacexposureattheemergencydepartmentacohorttypecrosssectionaldiagnosticaccuracystudy
AT jilmabernd performanceofaqualitativepointofcarestriptesttodetectdoacexposureattheemergencydepartmentacohorttypecrosssectionaldiagnosticaccuracystudy
AT spielalexandero performanceofaqualitativepointofcarestriptesttodetectdoacexposureattheemergencydepartmentacohorttypecrosssectionaldiagnosticaccuracystudy
AT schwameismichael performanceofaqualitativepointofcarestriptesttodetectdoacexposureattheemergencydepartmentacohorttypecrosssectionaldiagnosticaccuracystudy