Cargando…
A new quantitative 3D gap area measurement of fracture displacement of intra-articular distal radius fractures: Reliability and clinical applicability
INTRODUCTION: Gap and step-off measurements are generally used in the surgical decision-making process of distal radius fractures. Unfortunately, there is no consensus on treatment choice as these measurements are prone to inter- and intraobserver variability. In this study, we aim to introduce a ne...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9514643/ https://www.ncbi.nlm.nih.gov/pubmed/36166437 http://dx.doi.org/10.1371/journal.pone.0275206 |
_version_ | 1784798322096078848 |
---|---|
author | Roelofs, Lisanne J. M. Meesters, Anne M. L. Assink, Nick Kraeima, Joep Van der Meulen, Tim D. Doornberg, Job N. De Vries, Jean-Paul P. M. Hoekstra, Joost ten Duis, Kaj IJpma, Frank F. A. |
author_facet | Roelofs, Lisanne J. M. Meesters, Anne M. L. Assink, Nick Kraeima, Joep Van der Meulen, Tim D. Doornberg, Job N. De Vries, Jean-Paul P. M. Hoekstra, Joost ten Duis, Kaj IJpma, Frank F. A. |
author_sort | Roelofs, Lisanne J. M. |
collection | PubMed |
description | INTRODUCTION: Gap and step-off measurements are generally used in the surgical decision-making process of distal radius fractures. Unfortunately, there is no consensus on treatment choice as these measurements are prone to inter- and intraobserver variability. In this study, we aim to introduce a new 3D fracture quantification method and compare it to conventional fracture analysis. METHODS: Forty patients with a minimally displaced intra-articular distal radius fracture that was treated nonoperatively between 2008–2015 were included. 2D-CT images were reassessed by three orthopedic trauma surgeons who performed gap and step-off measurements. Subsequently, 3D models were created and a 3D measurement method for fracture displacement was developed. For each fracture, the ‘3D gap area’ (3D surface between all fracture fragments) was determined by three observers. Interobserver agreements were calculated for all measurements, and the intraobserver agreement was calculated for the new 3D measurement. All patients completed two questionnaires in order to link our measurements to functional outcome. RESULTS: The interobserver agreement of the 2D measurements was fair (ICC = 0.54) for the gap and poor (ICC = 0.21) for the step-off. The median gap was 2.8 (IQR: 1.9–3.5) mm and step-off was 0.9 (IQR: 0.0–1.6) mm. Interobserver agreement on 3D gap area measurements was excellent (ICC = 0.81), with a median difference between measurements of 6.0 (IQR: 2.0–19.0) mm(2), which indicates reliable assessment of 3D fracture displacement. Intraobserver agreement was also excellent (ICC = 0.98), with a median difference of 4.0 (IQR: 1.5–5.5) mm(2). No significant differences in clinical outcome were found between the above and below 2mm displacement groups. The score of the DASH was 3.4 (IQR: 0.4–8.8) versus 4.2 (IQR: 0.0–11.6) respectively. Results from the PRWE questionnaire shows a similar result of 3.5 (IQR: 0.0–12.6) versus 5.0 (IQR: 0.0–25.5). CONCLUSION: 3D gap area is a more objective measurement method compared to the conventional gap and step-off measurements to quantify the level of fracture displacement of distal radius fractures. 3D fracture assessment can be used in addition to the currently used classification systems of distal radius fractures. |
format | Online Article Text |
id | pubmed-9514643 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-95146432022-09-28 A new quantitative 3D gap area measurement of fracture displacement of intra-articular distal radius fractures: Reliability and clinical applicability Roelofs, Lisanne J. M. Meesters, Anne M. L. Assink, Nick Kraeima, Joep Van der Meulen, Tim D. Doornberg, Job N. De Vries, Jean-Paul P. M. Hoekstra, Joost ten Duis, Kaj IJpma, Frank F. A. PLoS One Research Article INTRODUCTION: Gap and step-off measurements are generally used in the surgical decision-making process of distal radius fractures. Unfortunately, there is no consensus on treatment choice as these measurements are prone to inter- and intraobserver variability. In this study, we aim to introduce a new 3D fracture quantification method and compare it to conventional fracture analysis. METHODS: Forty patients with a minimally displaced intra-articular distal radius fracture that was treated nonoperatively between 2008–2015 were included. 2D-CT images were reassessed by three orthopedic trauma surgeons who performed gap and step-off measurements. Subsequently, 3D models were created and a 3D measurement method for fracture displacement was developed. For each fracture, the ‘3D gap area’ (3D surface between all fracture fragments) was determined by three observers. Interobserver agreements were calculated for all measurements, and the intraobserver agreement was calculated for the new 3D measurement. All patients completed two questionnaires in order to link our measurements to functional outcome. RESULTS: The interobserver agreement of the 2D measurements was fair (ICC = 0.54) for the gap and poor (ICC = 0.21) for the step-off. The median gap was 2.8 (IQR: 1.9–3.5) mm and step-off was 0.9 (IQR: 0.0–1.6) mm. Interobserver agreement on 3D gap area measurements was excellent (ICC = 0.81), with a median difference between measurements of 6.0 (IQR: 2.0–19.0) mm(2), which indicates reliable assessment of 3D fracture displacement. Intraobserver agreement was also excellent (ICC = 0.98), with a median difference of 4.0 (IQR: 1.5–5.5) mm(2). No significant differences in clinical outcome were found between the above and below 2mm displacement groups. The score of the DASH was 3.4 (IQR: 0.4–8.8) versus 4.2 (IQR: 0.0–11.6) respectively. Results from the PRWE questionnaire shows a similar result of 3.5 (IQR: 0.0–12.6) versus 5.0 (IQR: 0.0–25.5). CONCLUSION: 3D gap area is a more objective measurement method compared to the conventional gap and step-off measurements to quantify the level of fracture displacement of distal radius fractures. 3D fracture assessment can be used in addition to the currently used classification systems of distal radius fractures. Public Library of Science 2022-09-27 /pmc/articles/PMC9514643/ /pubmed/36166437 http://dx.doi.org/10.1371/journal.pone.0275206 Text en © 2022 Roelofs et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Roelofs, Lisanne J. M. Meesters, Anne M. L. Assink, Nick Kraeima, Joep Van der Meulen, Tim D. Doornberg, Job N. De Vries, Jean-Paul P. M. Hoekstra, Joost ten Duis, Kaj IJpma, Frank F. A. A new quantitative 3D gap area measurement of fracture displacement of intra-articular distal radius fractures: Reliability and clinical applicability |
title | A new quantitative 3D gap area measurement of fracture displacement of intra-articular distal radius fractures: Reliability and clinical applicability |
title_full | A new quantitative 3D gap area measurement of fracture displacement of intra-articular distal radius fractures: Reliability and clinical applicability |
title_fullStr | A new quantitative 3D gap area measurement of fracture displacement of intra-articular distal radius fractures: Reliability and clinical applicability |
title_full_unstemmed | A new quantitative 3D gap area measurement of fracture displacement of intra-articular distal radius fractures: Reliability and clinical applicability |
title_short | A new quantitative 3D gap area measurement of fracture displacement of intra-articular distal radius fractures: Reliability and clinical applicability |
title_sort | new quantitative 3d gap area measurement of fracture displacement of intra-articular distal radius fractures: reliability and clinical applicability |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9514643/ https://www.ncbi.nlm.nih.gov/pubmed/36166437 http://dx.doi.org/10.1371/journal.pone.0275206 |
work_keys_str_mv | AT roelofslisannejm anewquantitative3dgapareameasurementoffracturedisplacementofintraarticulardistalradiusfracturesreliabilityandclinicalapplicability AT meestersanneml anewquantitative3dgapareameasurementoffracturedisplacementofintraarticulardistalradiusfracturesreliabilityandclinicalapplicability AT assinknick anewquantitative3dgapareameasurementoffracturedisplacementofintraarticulardistalradiusfracturesreliabilityandclinicalapplicability AT kraeimajoep anewquantitative3dgapareameasurementoffracturedisplacementofintraarticulardistalradiusfracturesreliabilityandclinicalapplicability AT vandermeulentimd anewquantitative3dgapareameasurementoffracturedisplacementofintraarticulardistalradiusfracturesreliabilityandclinicalapplicability AT doornbergjobn anewquantitative3dgapareameasurementoffracturedisplacementofintraarticulardistalradiusfracturesreliabilityandclinicalapplicability AT devriesjeanpaulpm anewquantitative3dgapareameasurementoffracturedisplacementofintraarticulardistalradiusfracturesreliabilityandclinicalapplicability AT hoekstrajoost anewquantitative3dgapareameasurementoffracturedisplacementofintraarticulardistalradiusfracturesreliabilityandclinicalapplicability AT tenduiskaj anewquantitative3dgapareameasurementoffracturedisplacementofintraarticulardistalradiusfracturesreliabilityandclinicalapplicability AT ijpmafrankfa anewquantitative3dgapareameasurementoffracturedisplacementofintraarticulardistalradiusfracturesreliabilityandclinicalapplicability AT roelofslisannejm newquantitative3dgapareameasurementoffracturedisplacementofintraarticulardistalradiusfracturesreliabilityandclinicalapplicability AT meestersanneml newquantitative3dgapareameasurementoffracturedisplacementofintraarticulardistalradiusfracturesreliabilityandclinicalapplicability AT assinknick newquantitative3dgapareameasurementoffracturedisplacementofintraarticulardistalradiusfracturesreliabilityandclinicalapplicability AT kraeimajoep newquantitative3dgapareameasurementoffracturedisplacementofintraarticulardistalradiusfracturesreliabilityandclinicalapplicability AT vandermeulentimd newquantitative3dgapareameasurementoffracturedisplacementofintraarticulardistalradiusfracturesreliabilityandclinicalapplicability AT doornbergjobn newquantitative3dgapareameasurementoffracturedisplacementofintraarticulardistalradiusfracturesreliabilityandclinicalapplicability AT devriesjeanpaulpm newquantitative3dgapareameasurementoffracturedisplacementofintraarticulardistalradiusfracturesreliabilityandclinicalapplicability AT hoekstrajoost newquantitative3dgapareameasurementoffracturedisplacementofintraarticulardistalradiusfracturesreliabilityandclinicalapplicability AT tenduiskaj newquantitative3dgapareameasurementoffracturedisplacementofintraarticulardistalradiusfracturesreliabilityandclinicalapplicability AT ijpmafrankfa newquantitative3dgapareameasurementoffracturedisplacementofintraarticulardistalradiusfracturesreliabilityandclinicalapplicability |