Cargando…
Comparison of single-shot EPI and multi-shot EPI in prostate DWI at 3.0 T
In prostate MRI, single-shot EPI (ssEPI) DWI still suffers from distortion and blurring. Multi-shot EPI (msEPI) overcomes the drawbacks of ssEPI DWI. The aim of this article was to compare the image quality and diagnostic performance for clinically significant prostate cancer (csPC) between ssEPI DW...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9515065/ https://www.ncbi.nlm.nih.gov/pubmed/36168032 http://dx.doi.org/10.1038/s41598-022-20518-8 |
_version_ | 1784798409805266944 |
---|---|
author | Tamada, Tsutomu Kido, Ayumu Ueda, Yu Takeuchi, Mitsuru Kanki, Akihiko Neelavalli, Jaladhar Yamamoto, Akira |
author_facet | Tamada, Tsutomu Kido, Ayumu Ueda, Yu Takeuchi, Mitsuru Kanki, Akihiko Neelavalli, Jaladhar Yamamoto, Akira |
author_sort | Tamada, Tsutomu |
collection | PubMed |
description | In prostate MRI, single-shot EPI (ssEPI) DWI still suffers from distortion and blurring. Multi-shot EPI (msEPI) overcomes the drawbacks of ssEPI DWI. The aim of this article was to compare the image quality and diagnostic performance for clinically significant prostate cancer (csPC) between ssEPI DWI and msEPI DWI. This retrospective study included 134 patients with suspected PC who underwent 3.0 T MRI and subsequent MRI-guided biopsy. Three radiologists independently assessed anatomical distortion, prostate edge clarity, and lesion conspicuity score for pathologically confirmed csPC. Lesion apparent diffusion coefficient (ADC) and benign ADC were also calculated. In 17 PC patients who underwent prostatectomy, three radiologists independently assessed eight prostate regions by DWI score in PI-RADS v 2.1. Anatomical distortion and prostate edge clarity were significantly higher in msEPI DWI than in ssEPI DWI in the three readers. Lesion conspicuity score was significantly higher in msEPI DWI than in ssEPI DWI in reader 1 and reader 3. Regarding discrimination ability between PC with GS ≤ 3 + 4 and PC with GS ≥ 4 + 3 using lesion ADC, AUC was comparable between ssEPI DWI and msEPI DWI. For diagnostic performance of csPC using DWI score, AUC was comparable between msEPI DWI and ssEPI DWI in all readers. Compared with ssEPI DWI, msEPI DWI had improved image quality and similar or higher diagnostic performance. |
format | Online Article Text |
id | pubmed-9515065 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-95150652022-09-29 Comparison of single-shot EPI and multi-shot EPI in prostate DWI at 3.0 T Tamada, Tsutomu Kido, Ayumu Ueda, Yu Takeuchi, Mitsuru Kanki, Akihiko Neelavalli, Jaladhar Yamamoto, Akira Sci Rep Article In prostate MRI, single-shot EPI (ssEPI) DWI still suffers from distortion and blurring. Multi-shot EPI (msEPI) overcomes the drawbacks of ssEPI DWI. The aim of this article was to compare the image quality and diagnostic performance for clinically significant prostate cancer (csPC) between ssEPI DWI and msEPI DWI. This retrospective study included 134 patients with suspected PC who underwent 3.0 T MRI and subsequent MRI-guided biopsy. Three radiologists independently assessed anatomical distortion, prostate edge clarity, and lesion conspicuity score for pathologically confirmed csPC. Lesion apparent diffusion coefficient (ADC) and benign ADC were also calculated. In 17 PC patients who underwent prostatectomy, three radiologists independently assessed eight prostate regions by DWI score in PI-RADS v 2.1. Anatomical distortion and prostate edge clarity were significantly higher in msEPI DWI than in ssEPI DWI in the three readers. Lesion conspicuity score was significantly higher in msEPI DWI than in ssEPI DWI in reader 1 and reader 3. Regarding discrimination ability between PC with GS ≤ 3 + 4 and PC with GS ≥ 4 + 3 using lesion ADC, AUC was comparable between ssEPI DWI and msEPI DWI. For diagnostic performance of csPC using DWI score, AUC was comparable between msEPI DWI and ssEPI DWI in all readers. Compared with ssEPI DWI, msEPI DWI had improved image quality and similar or higher diagnostic performance. Nature Publishing Group UK 2022-09-27 /pmc/articles/PMC9515065/ /pubmed/36168032 http://dx.doi.org/10.1038/s41598-022-20518-8 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Tamada, Tsutomu Kido, Ayumu Ueda, Yu Takeuchi, Mitsuru Kanki, Akihiko Neelavalli, Jaladhar Yamamoto, Akira Comparison of single-shot EPI and multi-shot EPI in prostate DWI at 3.0 T |
title | Comparison of single-shot EPI and multi-shot EPI in prostate DWI at 3.0 T |
title_full | Comparison of single-shot EPI and multi-shot EPI in prostate DWI at 3.0 T |
title_fullStr | Comparison of single-shot EPI and multi-shot EPI in prostate DWI at 3.0 T |
title_full_unstemmed | Comparison of single-shot EPI and multi-shot EPI in prostate DWI at 3.0 T |
title_short | Comparison of single-shot EPI and multi-shot EPI in prostate DWI at 3.0 T |
title_sort | comparison of single-shot epi and multi-shot epi in prostate dwi at 3.0 t |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9515065/ https://www.ncbi.nlm.nih.gov/pubmed/36168032 http://dx.doi.org/10.1038/s41598-022-20518-8 |
work_keys_str_mv | AT tamadatsutomu comparisonofsingleshotepiandmultishotepiinprostatedwiat30t AT kidoayumu comparisonofsingleshotepiandmultishotepiinprostatedwiat30t AT uedayu comparisonofsingleshotepiandmultishotepiinprostatedwiat30t AT takeuchimitsuru comparisonofsingleshotepiandmultishotepiinprostatedwiat30t AT kankiakihiko comparisonofsingleshotepiandmultishotepiinprostatedwiat30t AT neelavallijaladhar comparisonofsingleshotepiandmultishotepiinprostatedwiat30t AT yamamotoakira comparisonofsingleshotepiandmultishotepiinprostatedwiat30t |