Cargando…

Determination of proper band size for stainless steel crowns of primary second molars: A cross-sectional study

BACKGROUND AND OBJECTIVES: Fixed space maintainers are often used following primary tooth loss. In this process, selection of a proper band size for stainless steel crowns (SSCs) is often performed by trial and error, which increases the chairside time and risk of contamination of the tried bands wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Moradinia, Mohammad, Sarlak, Hamid, Mohammad-Rabei, Elham, Almasi-Hashiani, Amir, Shamsi, Alireza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9515559/
https://www.ncbi.nlm.nih.gov/pubmed/36188207
http://dx.doi.org/10.4103/jos.jos_6_22
_version_ 1784798510639480832
author Moradinia, Mohammad
Sarlak, Hamid
Mohammad-Rabei, Elham
Almasi-Hashiani, Amir
Shamsi, Alireza
author_facet Moradinia, Mohammad
Sarlak, Hamid
Mohammad-Rabei, Elham
Almasi-Hashiani, Amir
Shamsi, Alireza
author_sort Moradinia, Mohammad
collection PubMed
description BACKGROUND AND OBJECTIVES: Fixed space maintainers are often used following primary tooth loss. In this process, selection of a proper band size for stainless steel crowns (SSCs) is often performed by trial and error, which increases the chairside time and risk of contamination of the tried bands with saliva, blood, and gingival crevicular fluid, necessitating their subsequent sterilization. This study is aimed at determining the proper size of prefabricated bands for all SSCs of primary second molars. MATERIALS AND METHODS: In this cross-sectional study, seven examiners, including three orthodontists and four pediatric dentists attempted to select the proper band size for 24 primary second molar SSCs (3M). They selected the proper band size for each size of SSC six times in three sessions. The significance of all selected choices was carried out using the test of proportions. RESULTS: The most commonly selected bands for EU2, EU3, EU4, EU5, EU6, and EU7 SSCs were sizes 31+, 32+, 34, 35+, 37, and 38, respectively, and the proper bands for EL2, EL3, EL4, EL5, EL6, and EL7 SSCs were sizes 30, 31+, 32+, 33+, 35 and 36+, respectively. The difference in the frequency ratio of different choices for all sizes of SSCs was significant (P < 0.05). CONCLUSION: The current study determined the proper band size for all SSCs of primary maxillary and mandibular second molars. This information can help dental clinicians in selecting the proper band size for SSCs without trial and error.
format Online
Article
Text
id pubmed-9515559
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-95155592022-09-29 Determination of proper band size for stainless steel crowns of primary second molars: A cross-sectional study Moradinia, Mohammad Sarlak, Hamid Mohammad-Rabei, Elham Almasi-Hashiani, Amir Shamsi, Alireza J Orthod Sci Original Article BACKGROUND AND OBJECTIVES: Fixed space maintainers are often used following primary tooth loss. In this process, selection of a proper band size for stainless steel crowns (SSCs) is often performed by trial and error, which increases the chairside time and risk of contamination of the tried bands with saliva, blood, and gingival crevicular fluid, necessitating their subsequent sterilization. This study is aimed at determining the proper size of prefabricated bands for all SSCs of primary second molars. MATERIALS AND METHODS: In this cross-sectional study, seven examiners, including three orthodontists and four pediatric dentists attempted to select the proper band size for 24 primary second molar SSCs (3M). They selected the proper band size for each size of SSC six times in three sessions. The significance of all selected choices was carried out using the test of proportions. RESULTS: The most commonly selected bands for EU2, EU3, EU4, EU5, EU6, and EU7 SSCs were sizes 31+, 32+, 34, 35+, 37, and 38, respectively, and the proper bands for EL2, EL3, EL4, EL5, EL6, and EL7 SSCs were sizes 30, 31+, 32+, 33+, 35 and 36+, respectively. The difference in the frequency ratio of different choices for all sizes of SSCs was significant (P < 0.05). CONCLUSION: The current study determined the proper band size for all SSCs of primary maxillary and mandibular second molars. This information can help dental clinicians in selecting the proper band size for SSCs without trial and error. Wolters Kluwer - Medknow 2022-08-24 /pmc/articles/PMC9515559/ /pubmed/36188207 http://dx.doi.org/10.4103/jos.jos_6_22 Text en Copyright: © 2022 Journal of Orthodontic Science https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Moradinia, Mohammad
Sarlak, Hamid
Mohammad-Rabei, Elham
Almasi-Hashiani, Amir
Shamsi, Alireza
Determination of proper band size for stainless steel crowns of primary second molars: A cross-sectional study
title Determination of proper band size for stainless steel crowns of primary second molars: A cross-sectional study
title_full Determination of proper band size for stainless steel crowns of primary second molars: A cross-sectional study
title_fullStr Determination of proper band size for stainless steel crowns of primary second molars: A cross-sectional study
title_full_unstemmed Determination of proper band size for stainless steel crowns of primary second molars: A cross-sectional study
title_short Determination of proper band size for stainless steel crowns of primary second molars: A cross-sectional study
title_sort determination of proper band size for stainless steel crowns of primary second molars: a cross-sectional study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9515559/
https://www.ncbi.nlm.nih.gov/pubmed/36188207
http://dx.doi.org/10.4103/jos.jos_6_22
work_keys_str_mv AT moradiniamohammad determinationofproperbandsizeforstainlesssteelcrownsofprimarysecondmolarsacrosssectionalstudy
AT sarlakhamid determinationofproperbandsizeforstainlesssteelcrownsofprimarysecondmolarsacrosssectionalstudy
AT mohammadrabeielham determinationofproperbandsizeforstainlesssteelcrownsofprimarysecondmolarsacrosssectionalstudy
AT almasihashianiamir determinationofproperbandsizeforstainlesssteelcrownsofprimarysecondmolarsacrosssectionalstudy
AT shamsialireza determinationofproperbandsizeforstainlesssteelcrownsofprimarysecondmolarsacrosssectionalstudy