Cargando…
Effect of zirconium oxide nano-coating on frictional resistance of orthodontic wires
OBJECTIVES: Minimizing the frictional force between orthodontic wire and brackets is imperative to safely obtain a more favorable result by applying lower loads. Several methods have been proposed for this purpose such as changing the wire shape/size, changing the bracket design, and coating wires w...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9515563/ https://www.ncbi.nlm.nih.gov/pubmed/36188209 http://dx.doi.org/10.4103/jos.jos_154_21 |
Sumario: | OBJECTIVES: Minimizing the frictional force between orthodontic wire and brackets is imperative to safely obtain a more favorable result by applying lower loads. Several methods have been proposed for this purpose such as changing the wire shape/size, changing the bracket design, and coating wires with different materials. This study aimed to assess the effect of zirconium oxide (ZrO2) nano-coating on frictional resistance of three types of orthodontic wires. MATERIALS AND METHODS: This in vitro, experimental study evaluated 42 pieces of nickel-titanium (NiTi), stainless steel (SS), and beta-titanium (TMA) orthodontic wires, and 42 maxillary canine brackets. The samples were divided into six groups with and without ZrO2 nano-coating. The nano-coating was applied on the wires using the sol-gel technique. The presence of ZrO2 nano-coating was evaluated by scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX). The surface roughness of the samples was evaluated using atomic force microscopy (AFM). The brackets and wire had a 5° angle relative to each other. The static and kinetic friction of the samples were evaluated in the presence of artificial saliva and occlusogingival movements in a universal testing machine. Data were analyzed by the Shapiro–Wilk's test, one-way ANOVA, Kruskal–Walli's test, Mann–Whitney U test, independent t-test, and Tukey's test. RESULTS: ZrO2 nano-coating was only observed on TMA wires. The surface roughness of coated NiTi and SS wires had no significant difference from that of non-coated wires (P > 0.05). However, this difference was significant for TMA wires with and without the coating (P < 0.05). The static and kinetic friction were not significantly different between wires with and without coating (P > 0.05). CONCLUSIONS: ZrO2 nano-coating could only be applied on TMA wires, and had no significant efficacy for reduction of static or kinetic friction of TMA wires. |
---|