Cargando…
Endoscopic ultrasound elastography for malignant pancreatic masses and associated lymph nodes: Critical evaluation of strain ratio cutoff value
BACKGROUND: Endoscopic ultrasound (EUS) can detect small lesions throughout the digestive tract; however, it remains challenging to accurately identify malignancies with this approach. EUS elastography measures tissue hardness, by which malignant and nonmalignant pancreatic masses (PMs) and lymph no...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Baishideng Publishing Group Inc
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9516472/ https://www.ncbi.nlm.nih.gov/pubmed/36186947 http://dx.doi.org/10.4253/wjge.v14.i9.524 |
_version_ | 1784798716641673216 |
---|---|
author | Puga-Tejada, Miguel Del Valle, Raquel Oleas, Roberto Egas-Izquierdo, Maria Arevalo-Mora, Martha Baquerizo-Burgos, Jorge Ospina, Jesenia Soria-Alcivar, Miguel Pitanga-Lukashok, Hannah Robles-Medranda, Carlos |
author_facet | Puga-Tejada, Miguel Del Valle, Raquel Oleas, Roberto Egas-Izquierdo, Maria Arevalo-Mora, Martha Baquerizo-Burgos, Jorge Ospina, Jesenia Soria-Alcivar, Miguel Pitanga-Lukashok, Hannah Robles-Medranda, Carlos |
author_sort | Puga-Tejada, Miguel |
collection | PubMed |
description | BACKGROUND: Endoscopic ultrasound (EUS) can detect small lesions throughout the digestive tract; however, it remains challenging to accurately identify malignancies with this approach. EUS elastography measures tissue hardness, by which malignant and nonmalignant pancreatic masses (PMs) and lymph nodes (LNs) can be differentiated. However, there is currently little information regarding the strain ratio (SR) cutoff in Hispanic populations. AIM: To determine the diagnostic accuracy of EUS elastography for PMs and LNs with an SR cutoff value in Hispanics. METHODS: A retrospective study of patients who underwent EUS elastography for PMs between December 2013 and December 2014. A qualitative (analysis of color maps) and quantitative (SR) analysis of PMs and their associated LNs was performed. The accuracy of EUS elastography in identifying malignant PMs and LNs and cutoff value for SR were analyzed. A PM and/or its associated LNs were considered malignant based on histopathological findings from fine-needle aspiration biopsy samples. RESULTS: A sample of 121 patients was included, 45.4% of whom were female. 69 (57.0%) PMs were histologically malignant, with a median SR of 50.4 vs 33.0 for malignant vs nonmalignant masses (P < 0.001). EUS evaluation identified associated LNs in 43/121 patients (35.5%), in whom 22/43 (51.2%) patients had histologically confirmed malignant diagnosis, with a median SR of 30 vs 40 for malignant vs nonmalignant LNs (P = 0.7182). In detecting malignancy in PMs, an SR cutoff value of > 21.5 yielded a sensitivity of 94.2%, while a cutoff value of > 121 yielded a specificity of 96.2.2%. There were significant differences in the Giovannini scores, a previously established elastic score system, between the patients grouped by their final histology results (P < 0.001). For LNs, SR cutoff values of > 14.0 and > 155 yielded a sensitivity of 90.9% and a specificity of 95.2%, respectively, in detecting malignancy. CONCLUSION: EUS elastography is a helpful technique for the diagnosis of solid PMs and their associated LNs. The proposed SR cutoff values have a high sensitivity and specificity for the detection of malignancy. |
format | Online Article Text |
id | pubmed-9516472 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Baishideng Publishing Group Inc |
record_format | MEDLINE/PubMed |
spelling | pubmed-95164722022-09-29 Endoscopic ultrasound elastography for malignant pancreatic masses and associated lymph nodes: Critical evaluation of strain ratio cutoff value Puga-Tejada, Miguel Del Valle, Raquel Oleas, Roberto Egas-Izquierdo, Maria Arevalo-Mora, Martha Baquerizo-Burgos, Jorge Ospina, Jesenia Soria-Alcivar, Miguel Pitanga-Lukashok, Hannah Robles-Medranda, Carlos World J Gastrointest Endosc Case Control Study BACKGROUND: Endoscopic ultrasound (EUS) can detect small lesions throughout the digestive tract; however, it remains challenging to accurately identify malignancies with this approach. EUS elastography measures tissue hardness, by which malignant and nonmalignant pancreatic masses (PMs) and lymph nodes (LNs) can be differentiated. However, there is currently little information regarding the strain ratio (SR) cutoff in Hispanic populations. AIM: To determine the diagnostic accuracy of EUS elastography for PMs and LNs with an SR cutoff value in Hispanics. METHODS: A retrospective study of patients who underwent EUS elastography for PMs between December 2013 and December 2014. A qualitative (analysis of color maps) and quantitative (SR) analysis of PMs and their associated LNs was performed. The accuracy of EUS elastography in identifying malignant PMs and LNs and cutoff value for SR were analyzed. A PM and/or its associated LNs were considered malignant based on histopathological findings from fine-needle aspiration biopsy samples. RESULTS: A sample of 121 patients was included, 45.4% of whom were female. 69 (57.0%) PMs were histologically malignant, with a median SR of 50.4 vs 33.0 for malignant vs nonmalignant masses (P < 0.001). EUS evaluation identified associated LNs in 43/121 patients (35.5%), in whom 22/43 (51.2%) patients had histologically confirmed malignant diagnosis, with a median SR of 30 vs 40 for malignant vs nonmalignant LNs (P = 0.7182). In detecting malignancy in PMs, an SR cutoff value of > 21.5 yielded a sensitivity of 94.2%, while a cutoff value of > 121 yielded a specificity of 96.2.2%. There were significant differences in the Giovannini scores, a previously established elastic score system, between the patients grouped by their final histology results (P < 0.001). For LNs, SR cutoff values of > 14.0 and > 155 yielded a sensitivity of 90.9% and a specificity of 95.2%, respectively, in detecting malignancy. CONCLUSION: EUS elastography is a helpful technique for the diagnosis of solid PMs and their associated LNs. The proposed SR cutoff values have a high sensitivity and specificity for the detection of malignancy. Baishideng Publishing Group Inc 2022-09-16 2022-09-16 /pmc/articles/PMC9516472/ /pubmed/36186947 http://dx.doi.org/10.4253/wjge.v14.i9.524 Text en ©The Author(s) 2022. Published by Baishideng Publishing Group Inc. All rights reserved. https://creativecommons.org/licenses/by-nc/4.0/This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. |
spellingShingle | Case Control Study Puga-Tejada, Miguel Del Valle, Raquel Oleas, Roberto Egas-Izquierdo, Maria Arevalo-Mora, Martha Baquerizo-Burgos, Jorge Ospina, Jesenia Soria-Alcivar, Miguel Pitanga-Lukashok, Hannah Robles-Medranda, Carlos Endoscopic ultrasound elastography for malignant pancreatic masses and associated lymph nodes: Critical evaluation of strain ratio cutoff value |
title | Endoscopic ultrasound elastography for malignant pancreatic masses and associated lymph nodes: Critical evaluation of strain ratio cutoff value |
title_full | Endoscopic ultrasound elastography for malignant pancreatic masses and associated lymph nodes: Critical evaluation of strain ratio cutoff value |
title_fullStr | Endoscopic ultrasound elastography for malignant pancreatic masses and associated lymph nodes: Critical evaluation of strain ratio cutoff value |
title_full_unstemmed | Endoscopic ultrasound elastography for malignant pancreatic masses and associated lymph nodes: Critical evaluation of strain ratio cutoff value |
title_short | Endoscopic ultrasound elastography for malignant pancreatic masses and associated lymph nodes: Critical evaluation of strain ratio cutoff value |
title_sort | endoscopic ultrasound elastography for malignant pancreatic masses and associated lymph nodes: critical evaluation of strain ratio cutoff value |
topic | Case Control Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9516472/ https://www.ncbi.nlm.nih.gov/pubmed/36186947 http://dx.doi.org/10.4253/wjge.v14.i9.524 |
work_keys_str_mv | AT pugatejadamiguel endoscopicultrasoundelastographyformalignantpancreaticmassesandassociatedlymphnodescriticalevaluationofstrainratiocutoffvalue AT delvalleraquel endoscopicultrasoundelastographyformalignantpancreaticmassesandassociatedlymphnodescriticalevaluationofstrainratiocutoffvalue AT oleasroberto endoscopicultrasoundelastographyformalignantpancreaticmassesandassociatedlymphnodescriticalevaluationofstrainratiocutoffvalue AT egasizquierdomaria endoscopicultrasoundelastographyformalignantpancreaticmassesandassociatedlymphnodescriticalevaluationofstrainratiocutoffvalue AT arevalomoramartha endoscopicultrasoundelastographyformalignantpancreaticmassesandassociatedlymphnodescriticalevaluationofstrainratiocutoffvalue AT baquerizoburgosjorge endoscopicultrasoundelastographyformalignantpancreaticmassesandassociatedlymphnodescriticalevaluationofstrainratiocutoffvalue AT ospinajesenia endoscopicultrasoundelastographyformalignantpancreaticmassesandassociatedlymphnodescriticalevaluationofstrainratiocutoffvalue AT soriaalcivarmiguel endoscopicultrasoundelastographyformalignantpancreaticmassesandassociatedlymphnodescriticalevaluationofstrainratiocutoffvalue AT pitangalukashokhannah endoscopicultrasoundelastographyformalignantpancreaticmassesandassociatedlymphnodescriticalevaluationofstrainratiocutoffvalue AT roblesmedrandacarlos endoscopicultrasoundelastographyformalignantpancreaticmassesandassociatedlymphnodescriticalevaluationofstrainratiocutoffvalue |