Cargando…

Endoscopic ultrasound elastography for malignant pancreatic masses and associated lymph nodes: Critical evaluation of strain ratio cutoff value

BACKGROUND: Endoscopic ultrasound (EUS) can detect small lesions throughout the digestive tract; however, it remains challenging to accurately identify malignancies with this approach. EUS elastography measures tissue hardness, by which malignant and nonmalignant pancreatic masses (PMs) and lymph no...

Descripción completa

Detalles Bibliográficos
Autores principales: Puga-Tejada, Miguel, Del Valle, Raquel, Oleas, Roberto, Egas-Izquierdo, Maria, Arevalo-Mora, Martha, Baquerizo-Burgos, Jorge, Ospina, Jesenia, Soria-Alcivar, Miguel, Pitanga-Lukashok, Hannah, Robles-Medranda, Carlos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Baishideng Publishing Group Inc 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9516472/
https://www.ncbi.nlm.nih.gov/pubmed/36186947
http://dx.doi.org/10.4253/wjge.v14.i9.524
_version_ 1784798716641673216
author Puga-Tejada, Miguel
Del Valle, Raquel
Oleas, Roberto
Egas-Izquierdo, Maria
Arevalo-Mora, Martha
Baquerizo-Burgos, Jorge
Ospina, Jesenia
Soria-Alcivar, Miguel
Pitanga-Lukashok, Hannah
Robles-Medranda, Carlos
author_facet Puga-Tejada, Miguel
Del Valle, Raquel
Oleas, Roberto
Egas-Izquierdo, Maria
Arevalo-Mora, Martha
Baquerizo-Burgos, Jorge
Ospina, Jesenia
Soria-Alcivar, Miguel
Pitanga-Lukashok, Hannah
Robles-Medranda, Carlos
author_sort Puga-Tejada, Miguel
collection PubMed
description BACKGROUND: Endoscopic ultrasound (EUS) can detect small lesions throughout the digestive tract; however, it remains challenging to accurately identify malignancies with this approach. EUS elastography measures tissue hardness, by which malignant and nonmalignant pancreatic masses (PMs) and lymph nodes (LNs) can be differentiated. However, there is currently little information regarding the strain ratio (SR) cutoff in Hispanic populations. AIM: To determine the diagnostic accuracy of EUS elastography for PMs and LNs with an SR cutoff value in Hispanics. METHODS: A retrospective study of patients who underwent EUS elastography for PMs between December 2013 and December 2014. A qualitative (analysis of color maps) and quantitative (SR) analysis of PMs and their associated LNs was performed. The accuracy of EUS elastography in identifying malignant PMs and LNs and cutoff value for SR were analyzed. A PM and/or its associated LNs were considered malignant based on histopathological findings from fine-needle aspiration biopsy samples. RESULTS: A sample of 121 patients was included, 45.4% of whom were female. 69 (57.0%) PMs were histologically malignant, with a median SR of 50.4 vs 33.0 for malignant vs nonmalignant masses (P < 0.001). EUS evaluation identified associated LNs in 43/121 patients (35.5%), in whom 22/43 (51.2%) patients had histologically confirmed malignant diagnosis, with a median SR of 30 vs 40 for malignant vs nonmalignant LNs (P = 0.7182). In detecting malignancy in PMs, an SR cutoff value of > 21.5 yielded a sensitivity of 94.2%, while a cutoff value of > 121 yielded a specificity of 96.2.2%. There were significant differences in the Giovannini scores, a previously established elastic score system, between the patients grouped by their final histology results (P < 0.001). For LNs, SR cutoff values of > 14.0 and > 155 yielded a sensitivity of 90.9% and a specificity of 95.2%, respectively, in detecting malignancy. CONCLUSION: EUS elastography is a helpful technique for the diagnosis of solid PMs and their associated LNs. The proposed SR cutoff values have a high sensitivity and specificity for the detection of malignancy.
format Online
Article
Text
id pubmed-9516472
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Baishideng Publishing Group Inc
record_format MEDLINE/PubMed
spelling pubmed-95164722022-09-29 Endoscopic ultrasound elastography for malignant pancreatic masses and associated lymph nodes: Critical evaluation of strain ratio cutoff value Puga-Tejada, Miguel Del Valle, Raquel Oleas, Roberto Egas-Izquierdo, Maria Arevalo-Mora, Martha Baquerizo-Burgos, Jorge Ospina, Jesenia Soria-Alcivar, Miguel Pitanga-Lukashok, Hannah Robles-Medranda, Carlos World J Gastrointest Endosc Case Control Study BACKGROUND: Endoscopic ultrasound (EUS) can detect small lesions throughout the digestive tract; however, it remains challenging to accurately identify malignancies with this approach. EUS elastography measures tissue hardness, by which malignant and nonmalignant pancreatic masses (PMs) and lymph nodes (LNs) can be differentiated. However, there is currently little information regarding the strain ratio (SR) cutoff in Hispanic populations. AIM: To determine the diagnostic accuracy of EUS elastography for PMs and LNs with an SR cutoff value in Hispanics. METHODS: A retrospective study of patients who underwent EUS elastography for PMs between December 2013 and December 2014. A qualitative (analysis of color maps) and quantitative (SR) analysis of PMs and their associated LNs was performed. The accuracy of EUS elastography in identifying malignant PMs and LNs and cutoff value for SR were analyzed. A PM and/or its associated LNs were considered malignant based on histopathological findings from fine-needle aspiration biopsy samples. RESULTS: A sample of 121 patients was included, 45.4% of whom were female. 69 (57.0%) PMs were histologically malignant, with a median SR of 50.4 vs 33.0 for malignant vs nonmalignant masses (P < 0.001). EUS evaluation identified associated LNs in 43/121 patients (35.5%), in whom 22/43 (51.2%) patients had histologically confirmed malignant diagnosis, with a median SR of 30 vs 40 for malignant vs nonmalignant LNs (P = 0.7182). In detecting malignancy in PMs, an SR cutoff value of > 21.5 yielded a sensitivity of 94.2%, while a cutoff value of > 121 yielded a specificity of 96.2.2%. There were significant differences in the Giovannini scores, a previously established elastic score system, between the patients grouped by their final histology results (P < 0.001). For LNs, SR cutoff values of > 14.0 and > 155 yielded a sensitivity of 90.9% and a specificity of 95.2%, respectively, in detecting malignancy. CONCLUSION: EUS elastography is a helpful technique for the diagnosis of solid PMs and their associated LNs. The proposed SR cutoff values have a high sensitivity and specificity for the detection of malignancy. Baishideng Publishing Group Inc 2022-09-16 2022-09-16 /pmc/articles/PMC9516472/ /pubmed/36186947 http://dx.doi.org/10.4253/wjge.v14.i9.524 Text en ©The Author(s) 2022. Published by Baishideng Publishing Group Inc. All rights reserved. https://creativecommons.org/licenses/by-nc/4.0/This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial.
spellingShingle Case Control Study
Puga-Tejada, Miguel
Del Valle, Raquel
Oleas, Roberto
Egas-Izquierdo, Maria
Arevalo-Mora, Martha
Baquerizo-Burgos, Jorge
Ospina, Jesenia
Soria-Alcivar, Miguel
Pitanga-Lukashok, Hannah
Robles-Medranda, Carlos
Endoscopic ultrasound elastography for malignant pancreatic masses and associated lymph nodes: Critical evaluation of strain ratio cutoff value
title Endoscopic ultrasound elastography for malignant pancreatic masses and associated lymph nodes: Critical evaluation of strain ratio cutoff value
title_full Endoscopic ultrasound elastography for malignant pancreatic masses and associated lymph nodes: Critical evaluation of strain ratio cutoff value
title_fullStr Endoscopic ultrasound elastography for malignant pancreatic masses and associated lymph nodes: Critical evaluation of strain ratio cutoff value
title_full_unstemmed Endoscopic ultrasound elastography for malignant pancreatic masses and associated lymph nodes: Critical evaluation of strain ratio cutoff value
title_short Endoscopic ultrasound elastography for malignant pancreatic masses and associated lymph nodes: Critical evaluation of strain ratio cutoff value
title_sort endoscopic ultrasound elastography for malignant pancreatic masses and associated lymph nodes: critical evaluation of strain ratio cutoff value
topic Case Control Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9516472/
https://www.ncbi.nlm.nih.gov/pubmed/36186947
http://dx.doi.org/10.4253/wjge.v14.i9.524
work_keys_str_mv AT pugatejadamiguel endoscopicultrasoundelastographyformalignantpancreaticmassesandassociatedlymphnodescriticalevaluationofstrainratiocutoffvalue
AT delvalleraquel endoscopicultrasoundelastographyformalignantpancreaticmassesandassociatedlymphnodescriticalevaluationofstrainratiocutoffvalue
AT oleasroberto endoscopicultrasoundelastographyformalignantpancreaticmassesandassociatedlymphnodescriticalevaluationofstrainratiocutoffvalue
AT egasizquierdomaria endoscopicultrasoundelastographyformalignantpancreaticmassesandassociatedlymphnodescriticalevaluationofstrainratiocutoffvalue
AT arevalomoramartha endoscopicultrasoundelastographyformalignantpancreaticmassesandassociatedlymphnodescriticalevaluationofstrainratiocutoffvalue
AT baquerizoburgosjorge endoscopicultrasoundelastographyformalignantpancreaticmassesandassociatedlymphnodescriticalevaluationofstrainratiocutoffvalue
AT ospinajesenia endoscopicultrasoundelastographyformalignantpancreaticmassesandassociatedlymphnodescriticalevaluationofstrainratiocutoffvalue
AT soriaalcivarmiguel endoscopicultrasoundelastographyformalignantpancreaticmassesandassociatedlymphnodescriticalevaluationofstrainratiocutoffvalue
AT pitangalukashokhannah endoscopicultrasoundelastographyformalignantpancreaticmassesandassociatedlymphnodescriticalevaluationofstrainratiocutoffvalue
AT roblesmedrandacarlos endoscopicultrasoundelastographyformalignantpancreaticmassesandassociatedlymphnodescriticalevaluationofstrainratiocutoffvalue