Cargando…

Errors detected during physics plan review for external beam radiotherapy

BACKGROUND AND PURPOSE: Risk management in radiotherapy is of high importance. There is not much data published on errors occurring in the treatment planning process of external beam techniques. The aim of this study was to investigate errors occurring during physics plan review in external beam rad...

Descripción completa

Detalles Bibliográficos
Autores principales: Siebert, Frank-André, Hirt, Markus, Delaperrière, Marc, Dunst, Jürgen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9519775/
https://www.ncbi.nlm.nih.gov/pubmed/36185802
http://dx.doi.org/10.1016/j.phro.2022.09.006
_version_ 1784799476713521152
author Siebert, Frank-André
Hirt, Markus
Delaperrière, Marc
Dunst, Jürgen
author_facet Siebert, Frank-André
Hirt, Markus
Delaperrière, Marc
Dunst, Jürgen
author_sort Siebert, Frank-André
collection PubMed
description BACKGROUND AND PURPOSE: Risk management in radiotherapy is of high importance. There is not much data published on errors occurring in the treatment planning process of external beam techniques. The aim of this study was to investigate errors occurring during physics plan review in external beam radiotherapy. MATERIALS AND METHODS: Over a period of 14 months errors observed during the physical review process are reported. The errors were grouped and evaluated regarding treatment machine, technique, and treatment site. In addition, a correlation between frequency of errors and staff shortage was analyzed. RESULTS: Subgroups of grave errors (g-errors) and slight errors (s-errors) were defined to consider the different impact on the patient and clinical workflow of the errors. In 1056 plans reviewed, 110 errors (41 g-errors, 69 s-errors) were detected. The most common g-errors and s-errors were “Wrong gantry angle at setup field” (n = 19) and “Wrong field label” (n = 24), respectively. A correlation of number of errors and treatment machine, technique, or anatomical site could not be found. No correlation between staff shortage and number of errors was observed. CONCLUSIONS: The process of reviewing treatment plans is a relevant topic to consider in risk analysis of the radiotherapy workflow. The review process could be improved by enhancements in the treatment planning systems, use of digital dose prescription, and treatment planning templates.
format Online
Article
Text
id pubmed-9519775
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-95197752022-09-30 Errors detected during physics plan review for external beam radiotherapy Siebert, Frank-André Hirt, Markus Delaperrière, Marc Dunst, Jürgen Phys Imaging Radiat Oncol Original Research Article BACKGROUND AND PURPOSE: Risk management in radiotherapy is of high importance. There is not much data published on errors occurring in the treatment planning process of external beam techniques. The aim of this study was to investigate errors occurring during physics plan review in external beam radiotherapy. MATERIALS AND METHODS: Over a period of 14 months errors observed during the physical review process are reported. The errors were grouped and evaluated regarding treatment machine, technique, and treatment site. In addition, a correlation between frequency of errors and staff shortage was analyzed. RESULTS: Subgroups of grave errors (g-errors) and slight errors (s-errors) were defined to consider the different impact on the patient and clinical workflow of the errors. In 1056 plans reviewed, 110 errors (41 g-errors, 69 s-errors) were detected. The most common g-errors and s-errors were “Wrong gantry angle at setup field” (n = 19) and “Wrong field label” (n = 24), respectively. A correlation of number of errors and treatment machine, technique, or anatomical site could not be found. No correlation between staff shortage and number of errors was observed. CONCLUSIONS: The process of reviewing treatment plans is a relevant topic to consider in risk analysis of the radiotherapy workflow. The review process could be improved by enhancements in the treatment planning systems, use of digital dose prescription, and treatment planning templates. Elsevier 2022-09-17 /pmc/articles/PMC9519775/ /pubmed/36185802 http://dx.doi.org/10.1016/j.phro.2022.09.006 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research Article
Siebert, Frank-André
Hirt, Markus
Delaperrière, Marc
Dunst, Jürgen
Errors detected during physics plan review for external beam radiotherapy
title Errors detected during physics plan review for external beam radiotherapy
title_full Errors detected during physics plan review for external beam radiotherapy
title_fullStr Errors detected during physics plan review for external beam radiotherapy
title_full_unstemmed Errors detected during physics plan review for external beam radiotherapy
title_short Errors detected during physics plan review for external beam radiotherapy
title_sort errors detected during physics plan review for external beam radiotherapy
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9519775/
https://www.ncbi.nlm.nih.gov/pubmed/36185802
http://dx.doi.org/10.1016/j.phro.2022.09.006
work_keys_str_mv AT siebertfrankandre errorsdetectedduringphysicsplanreviewforexternalbeamradiotherapy
AT hirtmarkus errorsdetectedduringphysicsplanreviewforexternalbeamradiotherapy
AT delaperrieremarc errorsdetectedduringphysicsplanreviewforexternalbeamradiotherapy
AT dunstjurgen errorsdetectedduringphysicsplanreviewforexternalbeamradiotherapy