Cargando…
Robotic-assisted simple prostatectomy versus holmium laser enucleation of the prostate for large benign prostatic hyperplasia: A single-center preliminary study in Korea
BACKGROUND: Holmium laser enucleation of the prostate (HoLEP) and robotic-assisted simple prostatectomy (RASP) are the two most important therapeutic modalities for large benign prostatic hyperplasia. However, there are currently no studies comparing these two treatments in a Korean setting. In this...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Asian Pacific Prostate Society
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9520426/ https://www.ncbi.nlm.nih.gov/pubmed/36225286 http://dx.doi.org/10.1016/j.prnil.2022.05.004 |
_version_ | 1784799625290448896 |
---|---|
author | Kim, Byung Hoon Byun, Hye Jin |
author_facet | Kim, Byung Hoon Byun, Hye Jin |
author_sort | Kim, Byung Hoon |
collection | PubMed |
description | BACKGROUND: Holmium laser enucleation of the prostate (HoLEP) and robotic-assisted simple prostatectomy (RASP) are the two most important therapeutic modalities for large benign prostatic hyperplasia. However, there are currently no studies comparing these two treatments in a Korean setting. In this study, the authors seek to compare the safety and efficacy associated with these procedures. METHODS: The authors retrospectively analyzed 59 male patients who underwent HoLEP (n = 26) or RASP (n = 33) at single center. The following preoperative data were compared: age, the International Prostatic Symptom Score (IPSS), transrectal ultrasonography, uroflowmetry, and hemoglobin. Intraoperative data included operation time and specimen weight. Postoperative data included change in IPSS, uroflowmetry, and hemoglobin. Length of stay, catheterization time, and complications were also reviewed. RESULTS: No significant differences between the two groups were found in terms of age, total prostate, and transitional volume. Postoperatively, both groups showed similar improvement in the maximum flow rate, post-void residual urine, IPSS, and quality of life. Intraoperatively, there were no differences regarding operation time and resected prostate volume. Catheter removal time and length of stay were significantly shorter in the HoLEP group than the RASP group. In addition, postoperative hemoglobin changes were significantly lower in the HoLEP group. However, incontinence rates at 1 month and 2 months postoperative in the RASP group were lower than the HoLEP group. CONCLUSIONS: Both HoLEP and RASP can produce excellent postoperative outcomes. However, catheter removal time, length of stay, and hemoglobin changes were more favorable in the HoLEP group. On the other hand, postoperative incontinence was more favorable in the RASP group. These factors must be heavily considered when deciding surgical the method for large benign prostatic hyperplasia. |
format | Online Article Text |
id | pubmed-9520426 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Asian Pacific Prostate Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-95204262022-10-11 Robotic-assisted simple prostatectomy versus holmium laser enucleation of the prostate for large benign prostatic hyperplasia: A single-center preliminary study in Korea Kim, Byung Hoon Byun, Hye Jin Prostate Int Research Article BACKGROUND: Holmium laser enucleation of the prostate (HoLEP) and robotic-assisted simple prostatectomy (RASP) are the two most important therapeutic modalities for large benign prostatic hyperplasia. However, there are currently no studies comparing these two treatments in a Korean setting. In this study, the authors seek to compare the safety and efficacy associated with these procedures. METHODS: The authors retrospectively analyzed 59 male patients who underwent HoLEP (n = 26) or RASP (n = 33) at single center. The following preoperative data were compared: age, the International Prostatic Symptom Score (IPSS), transrectal ultrasonography, uroflowmetry, and hemoglobin. Intraoperative data included operation time and specimen weight. Postoperative data included change in IPSS, uroflowmetry, and hemoglobin. Length of stay, catheterization time, and complications were also reviewed. RESULTS: No significant differences between the two groups were found in terms of age, total prostate, and transitional volume. Postoperatively, both groups showed similar improvement in the maximum flow rate, post-void residual urine, IPSS, and quality of life. Intraoperatively, there were no differences regarding operation time and resected prostate volume. Catheter removal time and length of stay were significantly shorter in the HoLEP group than the RASP group. In addition, postoperative hemoglobin changes were significantly lower in the HoLEP group. However, incontinence rates at 1 month and 2 months postoperative in the RASP group were lower than the HoLEP group. CONCLUSIONS: Both HoLEP and RASP can produce excellent postoperative outcomes. However, catheter removal time, length of stay, and hemoglobin changes were more favorable in the HoLEP group. On the other hand, postoperative incontinence was more favorable in the RASP group. These factors must be heavily considered when deciding surgical the method for large benign prostatic hyperplasia. Asian Pacific Prostate Society 2022-09 2022-05-29 /pmc/articles/PMC9520426/ /pubmed/36225286 http://dx.doi.org/10.1016/j.prnil.2022.05.004 Text en © 2022 Asian Pacific Prostate Society. Publishing services by Elsevier B.V. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Research Article Kim, Byung Hoon Byun, Hye Jin Robotic-assisted simple prostatectomy versus holmium laser enucleation of the prostate for large benign prostatic hyperplasia: A single-center preliminary study in Korea |
title | Robotic-assisted simple prostatectomy versus holmium laser enucleation of the prostate for large benign prostatic hyperplasia: A single-center preliminary study in Korea |
title_full | Robotic-assisted simple prostatectomy versus holmium laser enucleation of the prostate for large benign prostatic hyperplasia: A single-center preliminary study in Korea |
title_fullStr | Robotic-assisted simple prostatectomy versus holmium laser enucleation of the prostate for large benign prostatic hyperplasia: A single-center preliminary study in Korea |
title_full_unstemmed | Robotic-assisted simple prostatectomy versus holmium laser enucleation of the prostate for large benign prostatic hyperplasia: A single-center preliminary study in Korea |
title_short | Robotic-assisted simple prostatectomy versus holmium laser enucleation of the prostate for large benign prostatic hyperplasia: A single-center preliminary study in Korea |
title_sort | robotic-assisted simple prostatectomy versus holmium laser enucleation of the prostate for large benign prostatic hyperplasia: a single-center preliminary study in korea |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9520426/ https://www.ncbi.nlm.nih.gov/pubmed/36225286 http://dx.doi.org/10.1016/j.prnil.2022.05.004 |
work_keys_str_mv | AT kimbyunghoon roboticassistedsimpleprostatectomyversusholmiumlaserenucleationoftheprostateforlargebenignprostatichyperplasiaasinglecenterpreliminarystudyinkorea AT byunhyejin roboticassistedsimpleprostatectomyversusholmiumlaserenucleationoftheprostateforlargebenignprostatichyperplasiaasinglecenterpreliminarystudyinkorea |