Cargando…

Detection of Axitinib Using Multiwalled Carbon Nanotube-Fe(2)O(3)/Chitosan Nanocomposite-Based Electrochemical Sensor and Modeling with Density Functional Theory

[Image: see text] In this study, axitinib (AXI), a potent and selective inhibitor of vascular endothelial growth factor receptor (VEGFR) tyrosine kinase and used as a second-generation targeted drug, was investigated electrochemically under optimized conditions using multiwalled carbon nanotubes/iro...

Descripción completa

Detalles Bibliográficos
Autores principales: Cetinkaya, Ahmet, Kaya, S. Irem, Şenel, Pelin, Cini, Nejla, Atici, Esen B., Ozkan, Sibel A., Yurtsever, Mine, Gölcü, Ayşegül
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9520732/
https://www.ncbi.nlm.nih.gov/pubmed/36188240
http://dx.doi.org/10.1021/acsomega.2c04244
_version_ 1784799692201132032
author Cetinkaya, Ahmet
Kaya, S. Irem
Şenel, Pelin
Cini, Nejla
Atici, Esen B.
Ozkan, Sibel A.
Yurtsever, Mine
Gölcü, Ayşegül
author_facet Cetinkaya, Ahmet
Kaya, S. Irem
Şenel, Pelin
Cini, Nejla
Atici, Esen B.
Ozkan, Sibel A.
Yurtsever, Mine
Gölcü, Ayşegül
author_sort Cetinkaya, Ahmet
collection PubMed
description [Image: see text] In this study, axitinib (AXI), a potent and selective inhibitor of vascular endothelial growth factor receptor (VEGFR) tyrosine kinase and used as a second-generation targeted drug, was investigated electrochemically under optimized conditions using multiwalled carbon nanotubes/iron(III) oxide nanoparticle–chitosan nanocomposite (MWCNT/Fe(2)O(3)@chitosan NC) modified on the glassy carbon electrode (GCE) surface. Characterization of the modified electrode was performed using scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). The adsorptive stripping differential pulse voltammetric (AdSDPV) technique was used for the sensitive, rapid, and precise detection of AXI. The current peak obtained with the MWCNT/Fe(2)O(3)@chitosan NC modified electrode was 23 times higher compared to the bare electrode. The developed modified electrode showed excellent electrocatalytic activity in AXI oxidation. Under optimized conditions, the effect of supporting electrolyte and pH was investigated, and 0.1 M H(2)SO(4) was chosen as the electrolyte with the highest peak current for the target analyte. In the concentration range of MWCNT/Fe(2)O(3)@chitosan NC/GCE, 6 × 10(–9) and 1 × 10(–6) M, the limit of detection (LOD) and limit of quantification (LOQ) values were calculated to be 0.904 and 0.0301 pM, respectively. Tablet and serum samples were used for the applicability of the developed sensor, relative standard deviation (RSD) values for all samples were below 2%, and the recovery results were 99.23 and 101.84%, respectively. The MWCNT/Fe(2)O(3)@chitosan NC/GCE designed to determine AXI demonstrated the applicability, selectivity, precision, and accuracy of the sensor. The mechanism of electron transfer from the modified GCE surface to the analyte solution is studied via modeling the modified GCE surface by the density functional theory (DFT) method at B3LYP/6-311+g(d,p) and M062X/6-31g(d,p) levels. We observed that the iron oxide nanoparticles play an important role in channeling electron flow from the analyte solution to the MWCNT-coated GCE electrode surface. Adsorption of the nanocomposite material onto the GCE surface occurs via strong electrostatic interactions, including ionic and hydrogen bond formations. During the adsorption-controlled oxidation process of the axitinib, the electrons are transferred via the highest occupied molecular orbital (HOMO) localized on the iron oxide moiety to the lowest unoccupied molecular orbital (LUMO) of the MWCNT/GCE surface.
format Online
Article
Text
id pubmed-9520732
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-95207322022-09-30 Detection of Axitinib Using Multiwalled Carbon Nanotube-Fe(2)O(3)/Chitosan Nanocomposite-Based Electrochemical Sensor and Modeling with Density Functional Theory Cetinkaya, Ahmet Kaya, S. Irem Şenel, Pelin Cini, Nejla Atici, Esen B. Ozkan, Sibel A. Yurtsever, Mine Gölcü, Ayşegül ACS Omega [Image: see text] In this study, axitinib (AXI), a potent and selective inhibitor of vascular endothelial growth factor receptor (VEGFR) tyrosine kinase and used as a second-generation targeted drug, was investigated electrochemically under optimized conditions using multiwalled carbon nanotubes/iron(III) oxide nanoparticle–chitosan nanocomposite (MWCNT/Fe(2)O(3)@chitosan NC) modified on the glassy carbon electrode (GCE) surface. Characterization of the modified electrode was performed using scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). The adsorptive stripping differential pulse voltammetric (AdSDPV) technique was used for the sensitive, rapid, and precise detection of AXI. The current peak obtained with the MWCNT/Fe(2)O(3)@chitosan NC modified electrode was 23 times higher compared to the bare electrode. The developed modified electrode showed excellent electrocatalytic activity in AXI oxidation. Under optimized conditions, the effect of supporting electrolyte and pH was investigated, and 0.1 M H(2)SO(4) was chosen as the electrolyte with the highest peak current for the target analyte. In the concentration range of MWCNT/Fe(2)O(3)@chitosan NC/GCE, 6 × 10(–9) and 1 × 10(–6) M, the limit of detection (LOD) and limit of quantification (LOQ) values were calculated to be 0.904 and 0.0301 pM, respectively. Tablet and serum samples were used for the applicability of the developed sensor, relative standard deviation (RSD) values for all samples were below 2%, and the recovery results were 99.23 and 101.84%, respectively. The MWCNT/Fe(2)O(3)@chitosan NC/GCE designed to determine AXI demonstrated the applicability, selectivity, precision, and accuracy of the sensor. The mechanism of electron transfer from the modified GCE surface to the analyte solution is studied via modeling the modified GCE surface by the density functional theory (DFT) method at B3LYP/6-311+g(d,p) and M062X/6-31g(d,p) levels. We observed that the iron oxide nanoparticles play an important role in channeling electron flow from the analyte solution to the MWCNT-coated GCE electrode surface. Adsorption of the nanocomposite material onto the GCE surface occurs via strong electrostatic interactions, including ionic and hydrogen bond formations. During the adsorption-controlled oxidation process of the axitinib, the electrons are transferred via the highest occupied molecular orbital (HOMO) localized on the iron oxide moiety to the lowest unoccupied molecular orbital (LUMO) of the MWCNT/GCE surface. American Chemical Society 2022-09-16 /pmc/articles/PMC9520732/ /pubmed/36188240 http://dx.doi.org/10.1021/acsomega.2c04244 Text en © 2022 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Cetinkaya, Ahmet
Kaya, S. Irem
Şenel, Pelin
Cini, Nejla
Atici, Esen B.
Ozkan, Sibel A.
Yurtsever, Mine
Gölcü, Ayşegül
Detection of Axitinib Using Multiwalled Carbon Nanotube-Fe(2)O(3)/Chitosan Nanocomposite-Based Electrochemical Sensor and Modeling with Density Functional Theory
title Detection of Axitinib Using Multiwalled Carbon Nanotube-Fe(2)O(3)/Chitosan Nanocomposite-Based Electrochemical Sensor and Modeling with Density Functional Theory
title_full Detection of Axitinib Using Multiwalled Carbon Nanotube-Fe(2)O(3)/Chitosan Nanocomposite-Based Electrochemical Sensor and Modeling with Density Functional Theory
title_fullStr Detection of Axitinib Using Multiwalled Carbon Nanotube-Fe(2)O(3)/Chitosan Nanocomposite-Based Electrochemical Sensor and Modeling with Density Functional Theory
title_full_unstemmed Detection of Axitinib Using Multiwalled Carbon Nanotube-Fe(2)O(3)/Chitosan Nanocomposite-Based Electrochemical Sensor and Modeling with Density Functional Theory
title_short Detection of Axitinib Using Multiwalled Carbon Nanotube-Fe(2)O(3)/Chitosan Nanocomposite-Based Electrochemical Sensor and Modeling with Density Functional Theory
title_sort detection of axitinib using multiwalled carbon nanotube-fe(2)o(3)/chitosan nanocomposite-based electrochemical sensor and modeling with density functional theory
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9520732/
https://www.ncbi.nlm.nih.gov/pubmed/36188240
http://dx.doi.org/10.1021/acsomega.2c04244
work_keys_str_mv AT cetinkayaahmet detectionofaxitinibusingmultiwalledcarbonnanotubefe2o3chitosannanocompositebasedelectrochemicalsensorandmodelingwithdensityfunctionaltheory
AT kayasirem detectionofaxitinibusingmultiwalledcarbonnanotubefe2o3chitosannanocompositebasedelectrochemicalsensorandmodelingwithdensityfunctionaltheory
AT senelpelin detectionofaxitinibusingmultiwalledcarbonnanotubefe2o3chitosannanocompositebasedelectrochemicalsensorandmodelingwithdensityfunctionaltheory
AT cininejla detectionofaxitinibusingmultiwalledcarbonnanotubefe2o3chitosannanocompositebasedelectrochemicalsensorandmodelingwithdensityfunctionaltheory
AT aticiesenb detectionofaxitinibusingmultiwalledcarbonnanotubefe2o3chitosannanocompositebasedelectrochemicalsensorandmodelingwithdensityfunctionaltheory
AT ozkansibela detectionofaxitinibusingmultiwalledcarbonnanotubefe2o3chitosannanocompositebasedelectrochemicalsensorandmodelingwithdensityfunctionaltheory
AT yurtsevermine detectionofaxitinibusingmultiwalledcarbonnanotubefe2o3chitosannanocompositebasedelectrochemicalsensorandmodelingwithdensityfunctionaltheory
AT golcuaysegul detectionofaxitinibusingmultiwalledcarbonnanotubefe2o3chitosannanocompositebasedelectrochemicalsensorandmodelingwithdensityfunctionaltheory