Cargando…

Potentiodynamic Poly(resorcinol)-Modified Glassy Carbon Electrode as a Voltammetric Sensor for Determining Cephalexin and Cefadroxil Simultaneously in Pharmaceutical Formulation and Biological Fluid Samples

[Image: see text] This study covers the development of a fast, selective, sensitive, and stable method for the simultaneous determination of cephalosporins (cephalexin (CLN) and cefadroxil (CFL)) in biological fluids and tablet samples using potentiodynamic fabrication of a poly(resorcinol)-modified...

Descripción completa

Detalles Bibliográficos
Autores principales: Kassa, Adane, Amare, Meareg, Benor, Amare, Tigineh, Getinet Tamiru, Beyene, Yonas, Tefera, Molla, Abebe, Atakilt
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9520737/
https://www.ncbi.nlm.nih.gov/pubmed/36188243
http://dx.doi.org/10.1021/acsomega.2c04514
_version_ 1784799693498220544
author Kassa, Adane
Amare, Meareg
Benor, Amare
Tigineh, Getinet Tamiru
Beyene, Yonas
Tefera, Molla
Abebe, Atakilt
author_facet Kassa, Adane
Amare, Meareg
Benor, Amare
Tigineh, Getinet Tamiru
Beyene, Yonas
Tefera, Molla
Abebe, Atakilt
author_sort Kassa, Adane
collection PubMed
description [Image: see text] This study covers the development of a fast, selective, sensitive, and stable method for the simultaneous determination of cephalosporins (cephalexin (CLN) and cefadroxil (CFL)) in biological fluids and tablet samples using potentiodynamic fabrication of a poly(resorcinol)-modified glassy carbon electrode (poly(reso)/GCE). The results of cyclic voltammetry and electrochemical impedance spectroscopy supported the modification of the GCE by a polymer layer that raised the electrode surface area and conductivity. At the poly(reso)/GCE, an irreversible oxidative peak with four- and fivefold current enhancement for CLN and CFL, respectively, at a substantially lower potential demonstrated the catalytic action of the modifier. Under optimized solution and parameters, the peak current response at the poly(reso)/GCE revealed a linear dependence on the concentration of CLN and CFL within the range 0.1–300 and 0.5–300 μM, respectively, with a limit of detection (LoD) of 3.12 and 8.7 nM, respectively. The levels of CLN in four selected tablet brands and CFL in two tablet brands were in the vicinity of 91.00–103.65% and 97.7–98.83%, respectively, of their nominal values. The recovery results for CLN in pharmaceutical samples were in the range of 99.00–100.67% and for CFL 97.9–99.75% and for blood serum and urine samples 99.55–100.55% and 99.33–100.34% for CLN and 97.13–100.60% and 96.73–102.50% for CFL, respectively. Interference recovery results with errors less than 4.81%, lower LoD, wider dynamic range, excellent recovery results, and good stability of the modifier compared to those for the previously reported methods validated the use of the poly(reso)/GCE for determining CLN and CFL simultaneously in various real samples.
format Online
Article
Text
id pubmed-9520737
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-95207372022-09-30 Potentiodynamic Poly(resorcinol)-Modified Glassy Carbon Electrode as a Voltammetric Sensor for Determining Cephalexin and Cefadroxil Simultaneously in Pharmaceutical Formulation and Biological Fluid Samples Kassa, Adane Amare, Meareg Benor, Amare Tigineh, Getinet Tamiru Beyene, Yonas Tefera, Molla Abebe, Atakilt ACS Omega [Image: see text] This study covers the development of a fast, selective, sensitive, and stable method for the simultaneous determination of cephalosporins (cephalexin (CLN) and cefadroxil (CFL)) in biological fluids and tablet samples using potentiodynamic fabrication of a poly(resorcinol)-modified glassy carbon electrode (poly(reso)/GCE). The results of cyclic voltammetry and electrochemical impedance spectroscopy supported the modification of the GCE by a polymer layer that raised the electrode surface area and conductivity. At the poly(reso)/GCE, an irreversible oxidative peak with four- and fivefold current enhancement for CLN and CFL, respectively, at a substantially lower potential demonstrated the catalytic action of the modifier. Under optimized solution and parameters, the peak current response at the poly(reso)/GCE revealed a linear dependence on the concentration of CLN and CFL within the range 0.1–300 and 0.5–300 μM, respectively, with a limit of detection (LoD) of 3.12 and 8.7 nM, respectively. The levels of CLN in four selected tablet brands and CFL in two tablet brands were in the vicinity of 91.00–103.65% and 97.7–98.83%, respectively, of their nominal values. The recovery results for CLN in pharmaceutical samples were in the range of 99.00–100.67% and for CFL 97.9–99.75% and for blood serum and urine samples 99.55–100.55% and 99.33–100.34% for CLN and 97.13–100.60% and 96.73–102.50% for CFL, respectively. Interference recovery results with errors less than 4.81%, lower LoD, wider dynamic range, excellent recovery results, and good stability of the modifier compared to those for the previously reported methods validated the use of the poly(reso)/GCE for determining CLN and CFL simultaneously in various real samples. American Chemical Society 2022-09-14 /pmc/articles/PMC9520737/ /pubmed/36188243 http://dx.doi.org/10.1021/acsomega.2c04514 Text en © 2022 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by-nc-nd/4.0/Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Kassa, Adane
Amare, Meareg
Benor, Amare
Tigineh, Getinet Tamiru
Beyene, Yonas
Tefera, Molla
Abebe, Atakilt
Potentiodynamic Poly(resorcinol)-Modified Glassy Carbon Electrode as a Voltammetric Sensor for Determining Cephalexin and Cefadroxil Simultaneously in Pharmaceutical Formulation and Biological Fluid Samples
title Potentiodynamic Poly(resorcinol)-Modified Glassy Carbon Electrode as a Voltammetric Sensor for Determining Cephalexin and Cefadroxil Simultaneously in Pharmaceutical Formulation and Biological Fluid Samples
title_full Potentiodynamic Poly(resorcinol)-Modified Glassy Carbon Electrode as a Voltammetric Sensor for Determining Cephalexin and Cefadroxil Simultaneously in Pharmaceutical Formulation and Biological Fluid Samples
title_fullStr Potentiodynamic Poly(resorcinol)-Modified Glassy Carbon Electrode as a Voltammetric Sensor for Determining Cephalexin and Cefadroxil Simultaneously in Pharmaceutical Formulation and Biological Fluid Samples
title_full_unstemmed Potentiodynamic Poly(resorcinol)-Modified Glassy Carbon Electrode as a Voltammetric Sensor for Determining Cephalexin and Cefadroxil Simultaneously in Pharmaceutical Formulation and Biological Fluid Samples
title_short Potentiodynamic Poly(resorcinol)-Modified Glassy Carbon Electrode as a Voltammetric Sensor for Determining Cephalexin and Cefadroxil Simultaneously in Pharmaceutical Formulation and Biological Fluid Samples
title_sort potentiodynamic poly(resorcinol)-modified glassy carbon electrode as a voltammetric sensor for determining cephalexin and cefadroxil simultaneously in pharmaceutical formulation and biological fluid samples
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9520737/
https://www.ncbi.nlm.nih.gov/pubmed/36188243
http://dx.doi.org/10.1021/acsomega.2c04514
work_keys_str_mv AT kassaadane potentiodynamicpolyresorcinolmodifiedglassycarbonelectrodeasavoltammetricsensorfordeterminingcephalexinandcefadroxilsimultaneouslyinpharmaceuticalformulationandbiologicalfluidsamples
AT amaremeareg potentiodynamicpolyresorcinolmodifiedglassycarbonelectrodeasavoltammetricsensorfordeterminingcephalexinandcefadroxilsimultaneouslyinpharmaceuticalformulationandbiologicalfluidsamples
AT benoramare potentiodynamicpolyresorcinolmodifiedglassycarbonelectrodeasavoltammetricsensorfordeterminingcephalexinandcefadroxilsimultaneouslyinpharmaceuticalformulationandbiologicalfluidsamples
AT tiginehgetinettamiru potentiodynamicpolyresorcinolmodifiedglassycarbonelectrodeasavoltammetricsensorfordeterminingcephalexinandcefadroxilsimultaneouslyinpharmaceuticalformulationandbiologicalfluidsamples
AT beyeneyonas potentiodynamicpolyresorcinolmodifiedglassycarbonelectrodeasavoltammetricsensorfordeterminingcephalexinandcefadroxilsimultaneouslyinpharmaceuticalformulationandbiologicalfluidsamples
AT teferamolla potentiodynamicpolyresorcinolmodifiedglassycarbonelectrodeasavoltammetricsensorfordeterminingcephalexinandcefadroxilsimultaneouslyinpharmaceuticalformulationandbiologicalfluidsamples
AT abebeatakilt potentiodynamicpolyresorcinolmodifiedglassycarbonelectrodeasavoltammetricsensorfordeterminingcephalexinandcefadroxilsimultaneouslyinpharmaceuticalformulationandbiologicalfluidsamples