Axial and frontal X-ray fluoroscopy technique of the sustentaculum tali can improve the accuracy of sustentacular screw placement
INTRODUCTION: Calcaneal fractures, especially those involving the articular surface, should be anatomically reduced as much as possible. Fixing the fracture by placing a screw into the sustentaculum tali from the lateral side of the calcaneus is generally considered to be the key to successful surge...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9520795/ https://www.ncbi.nlm.nih.gov/pubmed/36175879 http://dx.doi.org/10.1186/s12880-022-00898-z |
_version_ | 1784799705802211328 |
---|---|
author | Sun, Jian-Ning Zhu, Ai-Xiang Shi, Ce Zhang, Bei Tang, Guang-Sheng Wang, De-Guang Bing, Wang |
author_facet | Sun, Jian-Ning Zhu, Ai-Xiang Shi, Ce Zhang, Bei Tang, Guang-Sheng Wang, De-Guang Bing, Wang |
author_sort | Sun, Jian-Ning |
collection | PubMed |
description | INTRODUCTION: Calcaneal fractures, especially those involving the articular surface, should be anatomically reduced as much as possible. Fixing the fracture by placing a screw into the sustentaculum tali from the lateral side of the calcaneus is generally considered to be the key to successful surgery. However, due to the limited visibility during surgery, it is not easy to place screws into the sustentaculum tali accurately. The purpose of this study was to explore a new fluoroscopy method for the sustentaculum tali and verify the value of this method in improving screw placement accuracy. METHODS: In this study, a total of 42 human foot and ankle specimens were dissected and measured. The shape and position of the sustentaculum tali were observed, and the influence of adjacent bones on imaging findings was analysed. The axial and frontal X-ray fluoroscopy method to view the sustentaculum tali was formulated, and the appropriate projection angle through anatomical and image measurements was explored. Thirty specimens were randomly selected for screw placement, and the direction of the screw was dynamically adjusted under the new imaging method. The success rate of sustentacular screw placement was evaluated. RESULTS: The anteversion angles of the sustentaculum tali were 30.81 ± 2.21° and 30.68 ± 2.86° by anatomical and imaging measurements, respectively. There was no statistically significant difference in the anteversion angle between the two measurement methods. Harris heel views should be obtained at 30° to identify the sustentaculum tali on axial X-ray images. Frontal X-ray imaging was performed perpendicular to this projection angle. Through frontal and axial X-ray imaging, the position and shape of the sustentaculum tali can be clearly observed, and these factors are seldom affected by adjacent bones. Under the new fluoroscopy method, the screws were placed from the anterior region of the lateral wall of the calcaneus to the sustentaculum tali. A total of 60 screws were placed in the 30 specimens; of these, 54 screws were in good position, 2 screws penetrated the cortical bone, and 4 screws did not enter the sustentaculum tali. The success rate of sustentacular screw placement was 90% (54/60). CONCLUSIONS: Axial and frontal X-ray images of the sustentaculum tali can clearly show the shape of the structure, which improves sustentacular screw placement accuracy. |
format | Online Article Text |
id | pubmed-9520795 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-95207952022-09-30 Axial and frontal X-ray fluoroscopy technique of the sustentaculum tali can improve the accuracy of sustentacular screw placement Sun, Jian-Ning Zhu, Ai-Xiang Shi, Ce Zhang, Bei Tang, Guang-Sheng Wang, De-Guang Bing, Wang BMC Med Imaging Research INTRODUCTION: Calcaneal fractures, especially those involving the articular surface, should be anatomically reduced as much as possible. Fixing the fracture by placing a screw into the sustentaculum tali from the lateral side of the calcaneus is generally considered to be the key to successful surgery. However, due to the limited visibility during surgery, it is not easy to place screws into the sustentaculum tali accurately. The purpose of this study was to explore a new fluoroscopy method for the sustentaculum tali and verify the value of this method in improving screw placement accuracy. METHODS: In this study, a total of 42 human foot and ankle specimens were dissected and measured. The shape and position of the sustentaculum tali were observed, and the influence of adjacent bones on imaging findings was analysed. The axial and frontal X-ray fluoroscopy method to view the sustentaculum tali was formulated, and the appropriate projection angle through anatomical and image measurements was explored. Thirty specimens were randomly selected for screw placement, and the direction of the screw was dynamically adjusted under the new imaging method. The success rate of sustentacular screw placement was evaluated. RESULTS: The anteversion angles of the sustentaculum tali were 30.81 ± 2.21° and 30.68 ± 2.86° by anatomical and imaging measurements, respectively. There was no statistically significant difference in the anteversion angle between the two measurement methods. Harris heel views should be obtained at 30° to identify the sustentaculum tali on axial X-ray images. Frontal X-ray imaging was performed perpendicular to this projection angle. Through frontal and axial X-ray imaging, the position and shape of the sustentaculum tali can be clearly observed, and these factors are seldom affected by adjacent bones. Under the new fluoroscopy method, the screws were placed from the anterior region of the lateral wall of the calcaneus to the sustentaculum tali. A total of 60 screws were placed in the 30 specimens; of these, 54 screws were in good position, 2 screws penetrated the cortical bone, and 4 screws did not enter the sustentaculum tali. The success rate of sustentacular screw placement was 90% (54/60). CONCLUSIONS: Axial and frontal X-ray images of the sustentaculum tali can clearly show the shape of the structure, which improves sustentacular screw placement accuracy. BioMed Central 2022-09-29 /pmc/articles/PMC9520795/ /pubmed/36175879 http://dx.doi.org/10.1186/s12880-022-00898-z Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Sun, Jian-Ning Zhu, Ai-Xiang Shi, Ce Zhang, Bei Tang, Guang-Sheng Wang, De-Guang Bing, Wang Axial and frontal X-ray fluoroscopy technique of the sustentaculum tali can improve the accuracy of sustentacular screw placement |
title | Axial and frontal X-ray fluoroscopy technique of the sustentaculum tali can improve the accuracy of sustentacular screw placement |
title_full | Axial and frontal X-ray fluoroscopy technique of the sustentaculum tali can improve the accuracy of sustentacular screw placement |
title_fullStr | Axial and frontal X-ray fluoroscopy technique of the sustentaculum tali can improve the accuracy of sustentacular screw placement |
title_full_unstemmed | Axial and frontal X-ray fluoroscopy technique of the sustentaculum tali can improve the accuracy of sustentacular screw placement |
title_short | Axial and frontal X-ray fluoroscopy technique of the sustentaculum tali can improve the accuracy of sustentacular screw placement |
title_sort | axial and frontal x-ray fluoroscopy technique of the sustentaculum tali can improve the accuracy of sustentacular screw placement |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9520795/ https://www.ncbi.nlm.nih.gov/pubmed/36175879 http://dx.doi.org/10.1186/s12880-022-00898-z |
work_keys_str_mv | AT sunjianning axialandfrontalxrayfluoroscopytechniqueofthesustentaculumtalicanimprovetheaccuracyofsustentacularscrewplacement AT zhuaixiang axialandfrontalxrayfluoroscopytechniqueofthesustentaculumtalicanimprovetheaccuracyofsustentacularscrewplacement AT shice axialandfrontalxrayfluoroscopytechniqueofthesustentaculumtalicanimprovetheaccuracyofsustentacularscrewplacement AT zhangbei axialandfrontalxrayfluoroscopytechniqueofthesustentaculumtalicanimprovetheaccuracyofsustentacularscrewplacement AT tangguangsheng axialandfrontalxrayfluoroscopytechniqueofthesustentaculumtalicanimprovetheaccuracyofsustentacularscrewplacement AT wangdeguang axialandfrontalxrayfluoroscopytechniqueofthesustentaculumtalicanimprovetheaccuracyofsustentacularscrewplacement AT bingwang axialandfrontalxrayfluoroscopytechniqueofthesustentaculumtalicanimprovetheaccuracyofsustentacularscrewplacement |