Cargando…

Practices for running a research-oriented shared cryo-EM facility

The Harvard Cryo-Electron Microscopy Center for Structural Biology, which was formed as a consortium between Harvard Medical School, Boston Children’s Hospital, Dana-Farber Cancer Institute, and Massachusetts General Hospital, serves both academic and commercial users in the greater Harvard communit...

Descripción completa

Detalles Bibliográficos
Autores principales: Walsh, Richard M., Mayer, Megan L., Sun, Christopher H., Rawson, Shaun, Nair, Remya, Sterling, Sarah M., Li, Zongli
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9521047/
https://www.ncbi.nlm.nih.gov/pubmed/36188224
http://dx.doi.org/10.3389/fmolb.2022.960940
_version_ 1784799760736059392
author Walsh, Richard M.
Mayer, Megan L.
Sun, Christopher H.
Rawson, Shaun
Nair, Remya
Sterling, Sarah M.
Li, Zongli
author_facet Walsh, Richard M.
Mayer, Megan L.
Sun, Christopher H.
Rawson, Shaun
Nair, Remya
Sterling, Sarah M.
Li, Zongli
author_sort Walsh, Richard M.
collection PubMed
description The Harvard Cryo-Electron Microscopy Center for Structural Biology, which was formed as a consortium between Harvard Medical School, Boston Children’s Hospital, Dana-Farber Cancer Institute, and Massachusetts General Hospital, serves both academic and commercial users in the greater Harvard community. The facility strives to optimize research productivity while training users to become expert electron microscopists. These two tasks may be at odds and require careful balance to keep research projects moving forward while still allowing trainees to develop independence and expertise. This article presents the model developed at Harvard Medical School for running a research-oriented cryo-EM facility. Being a research-oriented facility begins with training in cryo-sample preparation on a trainee’s own sample, ideally producing grids that can be screened and optimized on the Talos Arctica via multiple established pipelines. The first option, staff assisted screening, requires no user experience and a staff member provides instant feedback about the suitability of the sample for cryo-EM investigation and discusses potential strategies for sample optimization. Another option, rapid access, allows users short sessions to screen samples and introductory training for basic microscope operation. Once a sample reaches the stage where data collection is warranted, new users are trained on setting up data collection for themselves on either the Talos Arctica or Titan Krios microscope until independence is established. By providing incremental training and screening pipelines, the bottleneck of sample preparation can be overcome in parallel with developing skills as an electron microscopist. This approach allows for the development of expertise without hindering breakthroughs in key research areas.
format Online
Article
Text
id pubmed-9521047
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-95210472022-09-30 Practices for running a research-oriented shared cryo-EM facility Walsh, Richard M. Mayer, Megan L. Sun, Christopher H. Rawson, Shaun Nair, Remya Sterling, Sarah M. Li, Zongli Front Mol Biosci Molecular Biosciences The Harvard Cryo-Electron Microscopy Center for Structural Biology, which was formed as a consortium between Harvard Medical School, Boston Children’s Hospital, Dana-Farber Cancer Institute, and Massachusetts General Hospital, serves both academic and commercial users in the greater Harvard community. The facility strives to optimize research productivity while training users to become expert electron microscopists. These two tasks may be at odds and require careful balance to keep research projects moving forward while still allowing trainees to develop independence and expertise. This article presents the model developed at Harvard Medical School for running a research-oriented cryo-EM facility. Being a research-oriented facility begins with training in cryo-sample preparation on a trainee’s own sample, ideally producing grids that can be screened and optimized on the Talos Arctica via multiple established pipelines. The first option, staff assisted screening, requires no user experience and a staff member provides instant feedback about the suitability of the sample for cryo-EM investigation and discusses potential strategies for sample optimization. Another option, rapid access, allows users short sessions to screen samples and introductory training for basic microscope operation. Once a sample reaches the stage where data collection is warranted, new users are trained on setting up data collection for themselves on either the Talos Arctica or Titan Krios microscope until independence is established. By providing incremental training and screening pipelines, the bottleneck of sample preparation can be overcome in parallel with developing skills as an electron microscopist. This approach allows for the development of expertise without hindering breakthroughs in key research areas. Frontiers Media S.A. 2022-09-15 /pmc/articles/PMC9521047/ /pubmed/36188224 http://dx.doi.org/10.3389/fmolb.2022.960940 Text en Copyright © 2022 Walsh, Mayer, Sun, Rawson, Nair, Sterling and Li. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Molecular Biosciences
Walsh, Richard M.
Mayer, Megan L.
Sun, Christopher H.
Rawson, Shaun
Nair, Remya
Sterling, Sarah M.
Li, Zongli
Practices for running a research-oriented shared cryo-EM facility
title Practices for running a research-oriented shared cryo-EM facility
title_full Practices for running a research-oriented shared cryo-EM facility
title_fullStr Practices for running a research-oriented shared cryo-EM facility
title_full_unstemmed Practices for running a research-oriented shared cryo-EM facility
title_short Practices for running a research-oriented shared cryo-EM facility
title_sort practices for running a research-oriented shared cryo-em facility
topic Molecular Biosciences
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9521047/
https://www.ncbi.nlm.nih.gov/pubmed/36188224
http://dx.doi.org/10.3389/fmolb.2022.960940
work_keys_str_mv AT walshrichardm practicesforrunningaresearchorientedsharedcryoemfacility
AT mayermeganl practicesforrunningaresearchorientedsharedcryoemfacility
AT sunchristopherh practicesforrunningaresearchorientedsharedcryoemfacility
AT rawsonshaun practicesforrunningaresearchorientedsharedcryoemfacility
AT nairremya practicesforrunningaresearchorientedsharedcryoemfacility
AT sterlingsarahm practicesforrunningaresearchorientedsharedcryoemfacility
AT lizongli practicesforrunningaresearchorientedsharedcryoemfacility