Cargando…
Evaluation of results and costs of high precision radiotherapy (VMAT) compared with conventional radiotherapy (3D) in the treatment of cancer patients with spinal cord compression of metastatic origin
BACKGROUND: The aim of this study was to evaluate the results and economic costs of using volumetric modulated arc therapy (VMAT) (5 fr × 5 Gy), compared with other conventional 3D radiotherapy schemes such as “5 × 4 Gy” and “10 × 3 Gy”. MATERIALS AND METHODS: The data about the direct costs for the...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Via Medica
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9521703/ https://www.ncbi.nlm.nih.gov/pubmed/36196419 http://dx.doi.org/10.5603/RPOR.a2022.0068 |
_version_ | 1784799899289649152 |
---|---|
author | Cacicedo, Jon Inhiesto, Elisa Gómez Ayesta, Maria Teresa Acaiturri Ustarroz, Iker Rades, Dirk |
author_facet | Cacicedo, Jon Inhiesto, Elisa Gómez Ayesta, Maria Teresa Acaiturri Ustarroz, Iker Rades, Dirk |
author_sort | Cacicedo, Jon |
collection | PubMed |
description | BACKGROUND: The aim of this study was to evaluate the results and economic costs of using volumetric modulated arc therapy (VMAT) (5 fr × 5 Gy), compared with other conventional 3D radiotherapy schemes such as “5 × 4 Gy” and “10 × 3 Gy”. MATERIALS AND METHODS: The data about the direct costs for the public health system was obtained from the Economic Information “Management per Patient” System available at the Integrated Health Organization Ezkerraldea Enkarterri Cruces. It is a model of real costs per patient which uses a bottom-up methodology which connects all sources of information generated in clinical practice, integrating healthcare information with economic information. This system presents the real cost per individualized patient, and shows the traceability of all clinical care. The costs of “typical patients” requiring hospital admission were identified for each of the three radiotherapy schemes based on the clinical activity and the material and human resources that were used. RESULTS: The 5 × 5 Gy scheme has a cost of EUR 4,801.48, which is 1.64% higher (EUR 77) than the “5 × 4 Gy” scheme (EUR 4,724.05). The “10 × 3 Gy” scheme has a cost of EUR 8,394.61, which is 74.8% higher (EUR 3,593) than the “5 × 5 Gy” scheme. The main cost factor in the “10 × 3 Gy” scheme is hospitalization, since patients are at hospital for 2 weeks compared with 1 week in the “5 × 5 Gy” scheme. CONCLUSIONS: The cost per patient of the VMAT “5 × 5 Gy” radiotherapy scheme is notably lower than that of the “10 × 3 Gy” scheme (conventional 3D radiotherapy), with the advantage of being administered in half the time. In relation to the scheme with 5 Gy × 4 sessions, the cost is similar to that of the “5 × 5 Gy” scheme. |
format | Online Article Text |
id | pubmed-9521703 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Via Medica |
record_format | MEDLINE/PubMed |
spelling | pubmed-95217032022-10-03 Evaluation of results and costs of high precision radiotherapy (VMAT) compared with conventional radiotherapy (3D) in the treatment of cancer patients with spinal cord compression of metastatic origin Cacicedo, Jon Inhiesto, Elisa Gómez Ayesta, Maria Teresa Acaiturri Ustarroz, Iker Rades, Dirk Rep Pract Oncol Radiother Research Paper BACKGROUND: The aim of this study was to evaluate the results and economic costs of using volumetric modulated arc therapy (VMAT) (5 fr × 5 Gy), compared with other conventional 3D radiotherapy schemes such as “5 × 4 Gy” and “10 × 3 Gy”. MATERIALS AND METHODS: The data about the direct costs for the public health system was obtained from the Economic Information “Management per Patient” System available at the Integrated Health Organization Ezkerraldea Enkarterri Cruces. It is a model of real costs per patient which uses a bottom-up methodology which connects all sources of information generated in clinical practice, integrating healthcare information with economic information. This system presents the real cost per individualized patient, and shows the traceability of all clinical care. The costs of “typical patients” requiring hospital admission were identified for each of the three radiotherapy schemes based on the clinical activity and the material and human resources that were used. RESULTS: The 5 × 5 Gy scheme has a cost of EUR 4,801.48, which is 1.64% higher (EUR 77) than the “5 × 4 Gy” scheme (EUR 4,724.05). The “10 × 3 Gy” scheme has a cost of EUR 8,394.61, which is 74.8% higher (EUR 3,593) than the “5 × 5 Gy” scheme. The main cost factor in the “10 × 3 Gy” scheme is hospitalization, since patients are at hospital for 2 weeks compared with 1 week in the “5 × 5 Gy” scheme. CONCLUSIONS: The cost per patient of the VMAT “5 × 5 Gy” radiotherapy scheme is notably lower than that of the “10 × 3 Gy” scheme (conventional 3D radiotherapy), with the advantage of being administered in half the time. In relation to the scheme with 5 Gy × 4 sessions, the cost is similar to that of the “5 × 5 Gy” scheme. Via Medica 2022-09-19 /pmc/articles/PMC9521703/ /pubmed/36196419 http://dx.doi.org/10.5603/RPOR.a2022.0068 Text en © 2022 Greater Poland Cancer Centre https://creativecommons.org/licenses/by-nc-nd/4.0/This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially |
spellingShingle | Research Paper Cacicedo, Jon Inhiesto, Elisa Gómez Ayesta, Maria Teresa Acaiturri Ustarroz, Iker Rades, Dirk Evaluation of results and costs of high precision radiotherapy (VMAT) compared with conventional radiotherapy (3D) in the treatment of cancer patients with spinal cord compression of metastatic origin |
title | Evaluation of results and costs of high precision radiotherapy (VMAT) compared with conventional radiotherapy (3D) in the treatment of cancer patients with spinal cord compression of metastatic origin |
title_full | Evaluation of results and costs of high precision radiotherapy (VMAT) compared with conventional radiotherapy (3D) in the treatment of cancer patients with spinal cord compression of metastatic origin |
title_fullStr | Evaluation of results and costs of high precision radiotherapy (VMAT) compared with conventional radiotherapy (3D) in the treatment of cancer patients with spinal cord compression of metastatic origin |
title_full_unstemmed | Evaluation of results and costs of high precision radiotherapy (VMAT) compared with conventional radiotherapy (3D) in the treatment of cancer patients with spinal cord compression of metastatic origin |
title_short | Evaluation of results and costs of high precision radiotherapy (VMAT) compared with conventional radiotherapy (3D) in the treatment of cancer patients with spinal cord compression of metastatic origin |
title_sort | evaluation of results and costs of high precision radiotherapy (vmat) compared with conventional radiotherapy (3d) in the treatment of cancer patients with spinal cord compression of metastatic origin |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9521703/ https://www.ncbi.nlm.nih.gov/pubmed/36196419 http://dx.doi.org/10.5603/RPOR.a2022.0068 |
work_keys_str_mv | AT cacicedojon evaluationofresultsandcostsofhighprecisionradiotherapyvmatcomparedwithconventionalradiotherapy3dinthetreatmentofcancerpatientswithspinalcordcompressionofmetastaticorigin AT inhiestoelisagomez evaluationofresultsandcostsofhighprecisionradiotherapyvmatcomparedwithconventionalradiotherapy3dinthetreatmentofcancerpatientswithspinalcordcompressionofmetastaticorigin AT ayestamariateresaacaiturri evaluationofresultsandcostsofhighprecisionradiotherapyvmatcomparedwithconventionalradiotherapy3dinthetreatmentofcancerpatientswithspinalcordcompressionofmetastaticorigin AT ustarroziker evaluationofresultsandcostsofhighprecisionradiotherapyvmatcomparedwithconventionalradiotherapy3dinthetreatmentofcancerpatientswithspinalcordcompressionofmetastaticorigin AT radesdirk evaluationofresultsandcostsofhighprecisionradiotherapyvmatcomparedwithconventionalradiotherapy3dinthetreatmentofcancerpatientswithspinalcordcompressionofmetastaticorigin |