Cargando…

Correlation of quantitative computed tomography derived bone density values with Hounsfield units of a contrast medium computed tomography in 98 thoraco-lumbar vertebral bodies

INTRODUCTION: Vertebral fractures in patients with bone density reduction are often a major challenge for the surgeon, as reduced bone density can lead to screw loosening. Several options are available to determine bone density preoperatively. In our study, we investigated the correlation of Hounsfi...

Descripción completa

Detalles Bibliográficos
Autores principales: Buenger, Fabian, Sakr, Yasser, Eckardt, Niklas, Senft, Christian, Schwarz, Falko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9522714/
https://www.ncbi.nlm.nih.gov/pubmed/34562119
http://dx.doi.org/10.1007/s00402-021-04184-5
_version_ 1784800117806596096
author Buenger, Fabian
Sakr, Yasser
Eckardt, Niklas
Senft, Christian
Schwarz, Falko
author_facet Buenger, Fabian
Sakr, Yasser
Eckardt, Niklas
Senft, Christian
Schwarz, Falko
author_sort Buenger, Fabian
collection PubMed
description INTRODUCTION: Vertebral fractures in patients with bone density reduction are often a major challenge for the surgeon, as reduced bone density can lead to screw loosening. Several options are available to determine bone density preoperatively. In our study, we investigated the correlation of Hounsfield units (HU) of a contrast medium computed tomography (CT) to the bone density values of a quantitative computed tomography (QCT) and computed a formula to estimate bone density values using HU. MATERIALS AND METHODS: In our retrospective data analysis, we examine 98 vertebral bodies from 35 patients who received a contrast medium CT of the spine and a QCT, performed no longer than 1 month apart. The determined HU from the contrast medium CT were compared with the bone density values of the QCT and examined for correlations. Linear logistic regression was used to estimate bone density values base on HU. RESULTS: A strong correlation was found between the HU measured in the CT and the bone density values (r = 0.894, p < 0.001), irrespective of patients’ gender. We also found no correlation differences when the HU were measured at different levels. Bland–Altman plot demonstrated good agreement between the two measurements. The following formula was developed to estimate bone density values using HU: QCT-value = 0.71 × HU + 13.82. CONCLUSIONS: Bone density values correlate well to HU measured in contrast medium CT. Using simple formula, the bone density of a contrast medium CT of vertebral bodies can be estimated based on HU without additional examinations and unnecessary costs.
format Online
Article
Text
id pubmed-9522714
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-95227142022-10-01 Correlation of quantitative computed tomography derived bone density values with Hounsfield units of a contrast medium computed tomography in 98 thoraco-lumbar vertebral bodies Buenger, Fabian Sakr, Yasser Eckardt, Niklas Senft, Christian Schwarz, Falko Arch Orthop Trauma Surg Trauma Surgery INTRODUCTION: Vertebral fractures in patients with bone density reduction are often a major challenge for the surgeon, as reduced bone density can lead to screw loosening. Several options are available to determine bone density preoperatively. In our study, we investigated the correlation of Hounsfield units (HU) of a contrast medium computed tomography (CT) to the bone density values of a quantitative computed tomography (QCT) and computed a formula to estimate bone density values using HU. MATERIALS AND METHODS: In our retrospective data analysis, we examine 98 vertebral bodies from 35 patients who received a contrast medium CT of the spine and a QCT, performed no longer than 1 month apart. The determined HU from the contrast medium CT were compared with the bone density values of the QCT and examined for correlations. Linear logistic regression was used to estimate bone density values base on HU. RESULTS: A strong correlation was found between the HU measured in the CT and the bone density values (r = 0.894, p < 0.001), irrespective of patients’ gender. We also found no correlation differences when the HU were measured at different levels. Bland–Altman plot demonstrated good agreement between the two measurements. The following formula was developed to estimate bone density values using HU: QCT-value = 0.71 × HU + 13.82. CONCLUSIONS: Bone density values correlate well to HU measured in contrast medium CT. Using simple formula, the bone density of a contrast medium CT of vertebral bodies can be estimated based on HU without additional examinations and unnecessary costs. Springer Berlin Heidelberg 2021-09-25 2022 /pmc/articles/PMC9522714/ /pubmed/34562119 http://dx.doi.org/10.1007/s00402-021-04184-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Trauma Surgery
Buenger, Fabian
Sakr, Yasser
Eckardt, Niklas
Senft, Christian
Schwarz, Falko
Correlation of quantitative computed tomography derived bone density values with Hounsfield units of a contrast medium computed tomography in 98 thoraco-lumbar vertebral bodies
title Correlation of quantitative computed tomography derived bone density values with Hounsfield units of a contrast medium computed tomography in 98 thoraco-lumbar vertebral bodies
title_full Correlation of quantitative computed tomography derived bone density values with Hounsfield units of a contrast medium computed tomography in 98 thoraco-lumbar vertebral bodies
title_fullStr Correlation of quantitative computed tomography derived bone density values with Hounsfield units of a contrast medium computed tomography in 98 thoraco-lumbar vertebral bodies
title_full_unstemmed Correlation of quantitative computed tomography derived bone density values with Hounsfield units of a contrast medium computed tomography in 98 thoraco-lumbar vertebral bodies
title_short Correlation of quantitative computed tomography derived bone density values with Hounsfield units of a contrast medium computed tomography in 98 thoraco-lumbar vertebral bodies
title_sort correlation of quantitative computed tomography derived bone density values with hounsfield units of a contrast medium computed tomography in 98 thoraco-lumbar vertebral bodies
topic Trauma Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9522714/
https://www.ncbi.nlm.nih.gov/pubmed/34562119
http://dx.doi.org/10.1007/s00402-021-04184-5
work_keys_str_mv AT buengerfabian correlationofquantitativecomputedtomographyderivedbonedensityvalueswithhounsfieldunitsofacontrastmediumcomputedtomographyin98thoracolumbarvertebralbodies
AT sakryasser correlationofquantitativecomputedtomographyderivedbonedensityvalueswithhounsfieldunitsofacontrastmediumcomputedtomographyin98thoracolumbarvertebralbodies
AT eckardtniklas correlationofquantitativecomputedtomographyderivedbonedensityvalueswithhounsfieldunitsofacontrastmediumcomputedtomographyin98thoracolumbarvertebralbodies
AT senftchristian correlationofquantitativecomputedtomographyderivedbonedensityvalueswithhounsfieldunitsofacontrastmediumcomputedtomographyin98thoracolumbarvertebralbodies
AT schwarzfalko correlationofquantitativecomputedtomographyderivedbonedensityvalueswithhounsfieldunitsofacontrastmediumcomputedtomographyin98thoracolumbarvertebralbodies