Effect of the prosthetic index on stress distribution in Morse taper connection implant system and peri-implant bone: a 3D finite element analysis
BACKGROUND: The combination of a prosthetic index with Morse taper connection was developed, with the purpose of making prosthetic procedures more precise. However, the presence of the index may compromise the mechanical performance of the abutment. The aim of this study is to evaluate the effect of...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9523891/ https://www.ncbi.nlm.nih.gov/pubmed/36180871 http://dx.doi.org/10.1186/s12903-022-02465-y |
_version_ | 1784800387846373376 |
---|---|
author | Zhang, Wen-tao Cheng, Kang-jie Liu, Yun-feng Wang, Russell Chen, Yun-fang Ding, Yu-de Yang, Fan Wang, Lin-hong |
author_facet | Zhang, Wen-tao Cheng, Kang-jie Liu, Yun-feng Wang, Russell Chen, Yun-fang Ding, Yu-de Yang, Fan Wang, Lin-hong |
author_sort | Zhang, Wen-tao |
collection | PubMed |
description | BACKGROUND: The combination of a prosthetic index with Morse taper connection was developed, with the purpose of making prosthetic procedures more precise. However, the presence of the index may compromise the mechanical performance of the abutment. The aim of this study is to evaluate the effect of prosthetic index on stress distribution in implant–abutment-screw system and peri-implant bone by using the 3D finite element methodology. METHODS: Two commercial dental implant systems with different implant–abutment connections were used: the Morse taper connection with platform switching (MT-PS) implant system and the internal hex connection with platform matching (IH-PM) implant system. Meanwhile, there are two different designs of Morse taper connection abutment, namely, abutments with or without index. Consequently, three different models were developed and evaluated: (1) MT-PS indexed, (2) MT-PS non-indexed, and (3) IH-PM. These models were inserted into a bone block. Vertical and oblique forces of 100 N were applied to each abutment to simulate occlusal loadings. RESULTS: For the MT-PS implant system, the maximum stress was always concentrated in the abutment neck under both vertical and oblique loading. Moreover, the maximum von Mises stress in the neck of the MT-PS abutment with index even exceed the yield strength of titanium alloy under the oblique loading. For the IH-PM implant system, however, the maximum stress was always located at the implant. Additionally, the MT-PS implant system has a significantly higher stress level in the abutment neck and a lower stress level around the peri-implant bone compared to the IH-PM implant system. The combined average maximum stress from vertical and oblique loads is 2.04 times higher in the MT-PS indexed model, and 1.82 times for the MT-PS non-indexed model than that of the IH-PM model. CONCLUSIONS: MT-PS with index will cause higher stress concentration on the abutment neck than that of without index, which is more prone to mechanical complications. Nevertheless, MT-PS decreases stress within cancellous bone and may contribute to limiting crestal bone resorption. |
format | Online Article Text |
id | pubmed-9523891 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-95238912022-10-01 Effect of the prosthetic index on stress distribution in Morse taper connection implant system and peri-implant bone: a 3D finite element analysis Zhang, Wen-tao Cheng, Kang-jie Liu, Yun-feng Wang, Russell Chen, Yun-fang Ding, Yu-de Yang, Fan Wang, Lin-hong BMC Oral Health Research BACKGROUND: The combination of a prosthetic index with Morse taper connection was developed, with the purpose of making prosthetic procedures more precise. However, the presence of the index may compromise the mechanical performance of the abutment. The aim of this study is to evaluate the effect of prosthetic index on stress distribution in implant–abutment-screw system and peri-implant bone by using the 3D finite element methodology. METHODS: Two commercial dental implant systems with different implant–abutment connections were used: the Morse taper connection with platform switching (MT-PS) implant system and the internal hex connection with platform matching (IH-PM) implant system. Meanwhile, there are two different designs of Morse taper connection abutment, namely, abutments with or without index. Consequently, three different models were developed and evaluated: (1) MT-PS indexed, (2) MT-PS non-indexed, and (3) IH-PM. These models were inserted into a bone block. Vertical and oblique forces of 100 N were applied to each abutment to simulate occlusal loadings. RESULTS: For the MT-PS implant system, the maximum stress was always concentrated in the abutment neck under both vertical and oblique loading. Moreover, the maximum von Mises stress in the neck of the MT-PS abutment with index even exceed the yield strength of titanium alloy under the oblique loading. For the IH-PM implant system, however, the maximum stress was always located at the implant. Additionally, the MT-PS implant system has a significantly higher stress level in the abutment neck and a lower stress level around the peri-implant bone compared to the IH-PM implant system. The combined average maximum stress from vertical and oblique loads is 2.04 times higher in the MT-PS indexed model, and 1.82 times for the MT-PS non-indexed model than that of the IH-PM model. CONCLUSIONS: MT-PS with index will cause higher stress concentration on the abutment neck than that of without index, which is more prone to mechanical complications. Nevertheless, MT-PS decreases stress within cancellous bone and may contribute to limiting crestal bone resorption. BioMed Central 2022-09-30 /pmc/articles/PMC9523891/ /pubmed/36180871 http://dx.doi.org/10.1186/s12903-022-02465-y Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Zhang, Wen-tao Cheng, Kang-jie Liu, Yun-feng Wang, Russell Chen, Yun-fang Ding, Yu-de Yang, Fan Wang, Lin-hong Effect of the prosthetic index on stress distribution in Morse taper connection implant system and peri-implant bone: a 3D finite element analysis |
title | Effect of the prosthetic index on stress distribution in Morse taper connection implant system and peri-implant bone: a 3D finite element analysis |
title_full | Effect of the prosthetic index on stress distribution in Morse taper connection implant system and peri-implant bone: a 3D finite element analysis |
title_fullStr | Effect of the prosthetic index on stress distribution in Morse taper connection implant system and peri-implant bone: a 3D finite element analysis |
title_full_unstemmed | Effect of the prosthetic index on stress distribution in Morse taper connection implant system and peri-implant bone: a 3D finite element analysis |
title_short | Effect of the prosthetic index on stress distribution in Morse taper connection implant system and peri-implant bone: a 3D finite element analysis |
title_sort | effect of the prosthetic index on stress distribution in morse taper connection implant system and peri-implant bone: a 3d finite element analysis |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9523891/ https://www.ncbi.nlm.nih.gov/pubmed/36180871 http://dx.doi.org/10.1186/s12903-022-02465-y |
work_keys_str_mv | AT zhangwentao effectoftheprostheticindexonstressdistributioninmorsetaperconnectionimplantsystemandperiimplantbonea3dfiniteelementanalysis AT chengkangjie effectoftheprostheticindexonstressdistributioninmorsetaperconnectionimplantsystemandperiimplantbonea3dfiniteelementanalysis AT liuyunfeng effectoftheprostheticindexonstressdistributioninmorsetaperconnectionimplantsystemandperiimplantbonea3dfiniteelementanalysis AT wangrussell effectoftheprostheticindexonstressdistributioninmorsetaperconnectionimplantsystemandperiimplantbonea3dfiniteelementanalysis AT chenyunfang effectoftheprostheticindexonstressdistributioninmorsetaperconnectionimplantsystemandperiimplantbonea3dfiniteelementanalysis AT dingyude effectoftheprostheticindexonstressdistributioninmorsetaperconnectionimplantsystemandperiimplantbonea3dfiniteelementanalysis AT yangfan effectoftheprostheticindexonstressdistributioninmorsetaperconnectionimplantsystemandperiimplantbonea3dfiniteelementanalysis AT wanglinhong effectoftheprostheticindexonstressdistributioninmorsetaperconnectionimplantsystemandperiimplantbonea3dfiniteelementanalysis |