Cargando…

The Diagnostic Value of 1.5T Versus 3.0T Magnetic Resonance Imaging Intratympanic Gadolinium Inner Ear Enhancement in Patients with Meniere’s Disease

BACKGROUND: A comparative study of 1.5T and 3.0T magnetic resonance imaging inner ear gadolinium enhancement was carried out to further explore the practicality and universality of 1.5T magnetic resonance imaging in the diagnosis of inner ear labyrinthine hydrops positive imaging. METHODS: This dual...

Descripción completa

Detalles Bibliográficos
Autores principales: Han, Yonping, Zhang, Junyi, Lui, Lei, Gao, Xia, Wu, Lei, Du, Xueqin, Fan, Wenjie, Xing, Ying, Chen, Xi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: European Academy of Otology and Neurotology and the Politzer Society 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9524368/
https://www.ncbi.nlm.nih.gov/pubmed/36063094
http://dx.doi.org/10.5152/iao.2022.21496
_version_ 1784800492931514368
author Han, Yonping
Zhang, Junyi
Lui, Lei
Gao, Xia
Wu, Lei
Du, Xueqin
Fan, Wenjie
Xing, Ying
Chen, Xi
author_facet Han, Yonping
Zhang, Junyi
Lui, Lei
Gao, Xia
Wu, Lei
Du, Xueqin
Fan, Wenjie
Xing, Ying
Chen, Xi
author_sort Han, Yonping
collection PubMed
description BACKGROUND: A comparative study of 1.5T and 3.0T magnetic resonance imaging inner ear gadolinium enhancement was carried out to further explore the practicality and universality of 1.5T magnetic resonance imaging in the diagnosis of inner ear labyrinthine hydrops positive imaging. METHODS: This dual case–control study was conducted on 25 patients with Meniere’s disease (experimental group), diagnosed by People’s Hospital of Ordos Dongsheng District between April 2017 and April 2019 and 51 patients with Meniere’s disease (control group), diagnosed by People’s Hospital Affiliated to Fujian University of Traditional Chinese Medicine between March 2010 and February 2011 and published on Chinese Medical Journal in 2011. Both groups were injected with gadolinium diluent into bilateral tympanic chambers through the tympanic membrane, and 3 dimensional-Fluid Attenuated Inversion Recovery (FLAIR) magnetic resonance imaging scanning of the inner ear was performed 24 hours later. The results of the 2 groups were observed, calculated, and statistically processed. RESULTS: The positive rate of membranous labyrinthine hydrops was 96% (24/25) in the experimental group and 96.1% (49/51) in the control group. The results are very close. CONCLUSION: In clinical diagnoses of Meniere’s disease, 1.5T magnetic resonance imaging and 3.0T magnetic resonance imaging have the same value and significance.
format Online
Article
Text
id pubmed-9524368
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher European Academy of Otology and Neurotology and the Politzer Society
record_format MEDLINE/PubMed
spelling pubmed-95243682022-10-13 The Diagnostic Value of 1.5T Versus 3.0T Magnetic Resonance Imaging Intratympanic Gadolinium Inner Ear Enhancement in Patients with Meniere’s Disease Han, Yonping Zhang, Junyi Lui, Lei Gao, Xia Wu, Lei Du, Xueqin Fan, Wenjie Xing, Ying Chen, Xi J Int Adv Otol Original Article BACKGROUND: A comparative study of 1.5T and 3.0T magnetic resonance imaging inner ear gadolinium enhancement was carried out to further explore the practicality and universality of 1.5T magnetic resonance imaging in the diagnosis of inner ear labyrinthine hydrops positive imaging. METHODS: This dual case–control study was conducted on 25 patients with Meniere’s disease (experimental group), diagnosed by People’s Hospital of Ordos Dongsheng District between April 2017 and April 2019 and 51 patients with Meniere’s disease (control group), diagnosed by People’s Hospital Affiliated to Fujian University of Traditional Chinese Medicine between March 2010 and February 2011 and published on Chinese Medical Journal in 2011. Both groups were injected with gadolinium diluent into bilateral tympanic chambers through the tympanic membrane, and 3 dimensional-Fluid Attenuated Inversion Recovery (FLAIR) magnetic resonance imaging scanning of the inner ear was performed 24 hours later. The results of the 2 groups were observed, calculated, and statistically processed. RESULTS: The positive rate of membranous labyrinthine hydrops was 96% (24/25) in the experimental group and 96.1% (49/51) in the control group. The results are very close. CONCLUSION: In clinical diagnoses of Meniere’s disease, 1.5T magnetic resonance imaging and 3.0T magnetic resonance imaging have the same value and significance. European Academy of Otology and Neurotology and the Politzer Society 2022-09-01 /pmc/articles/PMC9524368/ /pubmed/36063094 http://dx.doi.org/10.5152/iao.2022.21496 Text en 2022 authors https://creativecommons.org/licenses/by-nc/4.0/ Content of this journal is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. (https://creativecommons.org/licenses/by-nc/4.0/)
spellingShingle Original Article
Han, Yonping
Zhang, Junyi
Lui, Lei
Gao, Xia
Wu, Lei
Du, Xueqin
Fan, Wenjie
Xing, Ying
Chen, Xi
The Diagnostic Value of 1.5T Versus 3.0T Magnetic Resonance Imaging Intratympanic Gadolinium Inner Ear Enhancement in Patients with Meniere’s Disease
title The Diagnostic Value of 1.5T Versus 3.0T Magnetic Resonance Imaging Intratympanic Gadolinium Inner Ear Enhancement in Patients with Meniere’s Disease
title_full The Diagnostic Value of 1.5T Versus 3.0T Magnetic Resonance Imaging Intratympanic Gadolinium Inner Ear Enhancement in Patients with Meniere’s Disease
title_fullStr The Diagnostic Value of 1.5T Versus 3.0T Magnetic Resonance Imaging Intratympanic Gadolinium Inner Ear Enhancement in Patients with Meniere’s Disease
title_full_unstemmed The Diagnostic Value of 1.5T Versus 3.0T Magnetic Resonance Imaging Intratympanic Gadolinium Inner Ear Enhancement in Patients with Meniere’s Disease
title_short The Diagnostic Value of 1.5T Versus 3.0T Magnetic Resonance Imaging Intratympanic Gadolinium Inner Ear Enhancement in Patients with Meniere’s Disease
title_sort diagnostic value of 1.5t versus 3.0t magnetic resonance imaging intratympanic gadolinium inner ear enhancement in patients with meniere’s disease
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9524368/
https://www.ncbi.nlm.nih.gov/pubmed/36063094
http://dx.doi.org/10.5152/iao.2022.21496
work_keys_str_mv AT hanyonping thediagnosticvalueof15tversus30tmagneticresonanceimagingintratympanicgadoliniuminnerearenhancementinpatientswithmenieresdisease
AT zhangjunyi thediagnosticvalueof15tversus30tmagneticresonanceimagingintratympanicgadoliniuminnerearenhancementinpatientswithmenieresdisease
AT luilei thediagnosticvalueof15tversus30tmagneticresonanceimagingintratympanicgadoliniuminnerearenhancementinpatientswithmenieresdisease
AT gaoxia thediagnosticvalueof15tversus30tmagneticresonanceimagingintratympanicgadoliniuminnerearenhancementinpatientswithmenieresdisease
AT wulei thediagnosticvalueof15tversus30tmagneticresonanceimagingintratympanicgadoliniuminnerearenhancementinpatientswithmenieresdisease
AT duxueqin thediagnosticvalueof15tversus30tmagneticresonanceimagingintratympanicgadoliniuminnerearenhancementinpatientswithmenieresdisease
AT fanwenjie thediagnosticvalueof15tversus30tmagneticresonanceimagingintratympanicgadoliniuminnerearenhancementinpatientswithmenieresdisease
AT xingying thediagnosticvalueof15tversus30tmagneticresonanceimagingintratympanicgadoliniuminnerearenhancementinpatientswithmenieresdisease
AT chenxi thediagnosticvalueof15tversus30tmagneticresonanceimagingintratympanicgadoliniuminnerearenhancementinpatientswithmenieresdisease
AT hanyonping diagnosticvalueof15tversus30tmagneticresonanceimagingintratympanicgadoliniuminnerearenhancementinpatientswithmenieresdisease
AT zhangjunyi diagnosticvalueof15tversus30tmagneticresonanceimagingintratympanicgadoliniuminnerearenhancementinpatientswithmenieresdisease
AT luilei diagnosticvalueof15tversus30tmagneticresonanceimagingintratympanicgadoliniuminnerearenhancementinpatientswithmenieresdisease
AT gaoxia diagnosticvalueof15tversus30tmagneticresonanceimagingintratympanicgadoliniuminnerearenhancementinpatientswithmenieresdisease
AT wulei diagnosticvalueof15tversus30tmagneticresonanceimagingintratympanicgadoliniuminnerearenhancementinpatientswithmenieresdisease
AT duxueqin diagnosticvalueof15tversus30tmagneticresonanceimagingintratympanicgadoliniuminnerearenhancementinpatientswithmenieresdisease
AT fanwenjie diagnosticvalueof15tversus30tmagneticresonanceimagingintratympanicgadoliniuminnerearenhancementinpatientswithmenieresdisease
AT xingying diagnosticvalueof15tversus30tmagneticresonanceimagingintratympanicgadoliniuminnerearenhancementinpatientswithmenieresdisease
AT chenxi diagnosticvalueof15tversus30tmagneticresonanceimagingintratympanicgadoliniuminnerearenhancementinpatientswithmenieresdisease