Cargando…

A Simple Method to Improve Intraoperative Localization of Fiducial Markers during Lung Resections

Background  Lung cancer screening programs have increased the detection of early-stage lung cancer. High-resolution computed tomography can detect small, low-density pulmonary nodules, or ground-glass opacities. Obtaining a tissue diagnosis can be challenging, often necessitating surgical diagnosis....

Descripción completa

Detalles Bibliográficos
Autores principales: He, Shengliang, Beamer, Staci, Jaroszewski, Dawn, D'Cunha, Jonathan, Ravanbakhsh, Samine
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Georg Thieme Verlag KG 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9525182/
https://www.ncbi.nlm.nih.gov/pubmed/36187730
http://dx.doi.org/10.1055/s-0042-1756299
_version_ 1784800652390563840
author He, Shengliang
Beamer, Staci
Jaroszewski, Dawn
D'Cunha, Jonathan
Ravanbakhsh, Samine
author_facet He, Shengliang
Beamer, Staci
Jaroszewski, Dawn
D'Cunha, Jonathan
Ravanbakhsh, Samine
author_sort He, Shengliang
collection PubMed
description Background  Lung cancer screening programs have increased the detection of early-stage lung cancer. High-resolution computed tomography can detect small, low-density pulmonary nodules, or ground-glass opacities. Obtaining a tissue diagnosis can be challenging, often necessitating surgical diagnosis. Preoperative localization and intraoperative fluoroscopy are valuable tools to guide resections for small pulmonary nodules. Case Description  We present three cases using intraoperative fluoroscopy and Faxitron Bioptics that enhanced our certainty of resection of nonpalpable nodules. Conclusion  We support the use of intraoperative fluoroscopy with the unique addition of Faxitron BioVision as safe and reliable methods to enhance the certainty of resection.
format Online
Article
Text
id pubmed-9525182
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Georg Thieme Verlag KG
record_format MEDLINE/PubMed
spelling pubmed-95251822022-10-01 A Simple Method to Improve Intraoperative Localization of Fiducial Markers during Lung Resections He, Shengliang Beamer, Staci Jaroszewski, Dawn D'Cunha, Jonathan Ravanbakhsh, Samine Thorac Cardiovasc Surg Rep Background  Lung cancer screening programs have increased the detection of early-stage lung cancer. High-resolution computed tomography can detect small, low-density pulmonary nodules, or ground-glass opacities. Obtaining a tissue diagnosis can be challenging, often necessitating surgical diagnosis. Preoperative localization and intraoperative fluoroscopy are valuable tools to guide resections for small pulmonary nodules. Case Description  We present three cases using intraoperative fluoroscopy and Faxitron Bioptics that enhanced our certainty of resection of nonpalpable nodules. Conclusion  We support the use of intraoperative fluoroscopy with the unique addition of Faxitron BioVision as safe and reliable methods to enhance the certainty of resection. Georg Thieme Verlag KG 2022-09-30 /pmc/articles/PMC9525182/ /pubmed/36187730 http://dx.doi.org/10.1055/s-0042-1756299 Text en The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. ( https://creativecommons.org/licenses/by-nc-nd/4.0/ ) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle He, Shengliang
Beamer, Staci
Jaroszewski, Dawn
D'Cunha, Jonathan
Ravanbakhsh, Samine
A Simple Method to Improve Intraoperative Localization of Fiducial Markers during Lung Resections
title A Simple Method to Improve Intraoperative Localization of Fiducial Markers during Lung Resections
title_full A Simple Method to Improve Intraoperative Localization of Fiducial Markers during Lung Resections
title_fullStr A Simple Method to Improve Intraoperative Localization of Fiducial Markers during Lung Resections
title_full_unstemmed A Simple Method to Improve Intraoperative Localization of Fiducial Markers during Lung Resections
title_short A Simple Method to Improve Intraoperative Localization of Fiducial Markers during Lung Resections
title_sort simple method to improve intraoperative localization of fiducial markers during lung resections
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9525182/
https://www.ncbi.nlm.nih.gov/pubmed/36187730
http://dx.doi.org/10.1055/s-0042-1756299
work_keys_str_mv AT heshengliang asimplemethodtoimproveintraoperativelocalizationoffiducialmarkersduringlungresections
AT beamerstaci asimplemethodtoimproveintraoperativelocalizationoffiducialmarkersduringlungresections
AT jaroszewskidawn asimplemethodtoimproveintraoperativelocalizationoffiducialmarkersduringlungresections
AT dcunhajonathan asimplemethodtoimproveintraoperativelocalizationoffiducialmarkersduringlungresections
AT ravanbakhshsamine asimplemethodtoimproveintraoperativelocalizationoffiducialmarkersduringlungresections
AT heshengliang simplemethodtoimproveintraoperativelocalizationoffiducialmarkersduringlungresections
AT beamerstaci simplemethodtoimproveintraoperativelocalizationoffiducialmarkersduringlungresections
AT jaroszewskidawn simplemethodtoimproveintraoperativelocalizationoffiducialmarkersduringlungresections
AT dcunhajonathan simplemethodtoimproveintraoperativelocalizationoffiducialmarkersduringlungresections
AT ravanbakhshsamine simplemethodtoimproveintraoperativelocalizationoffiducialmarkersduringlungresections