Cargando…

Suction cup on a piston-based chest compression device improves coronary perfusion pressure and cerebral oxygenation during experimental cardiopulmonary resuscitation

INTRODUCTION: The presented study aimed to investigate whether a mechanical chest compression piston device with a suction cup assisting chest recoil could impact the hemodynamic status when compared to a bare piston during cardiopulmonary resuscitation. METHODS: 16 piglets were anesthetized and ran...

Descripción completa

Detalles Bibliográficos
Autores principales: Mälberg, Johan, Smekal, David, Marchesi, Silvia, Lipcsey, Miklós, Rubertsson, Sten
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9525897/
https://www.ncbi.nlm.nih.gov/pubmed/36193235
http://dx.doi.org/10.1016/j.resplu.2022.100311
_version_ 1784800767623823360
author Mälberg, Johan
Smekal, David
Marchesi, Silvia
Lipcsey, Miklós
Rubertsson, Sten
author_facet Mälberg, Johan
Smekal, David
Marchesi, Silvia
Lipcsey, Miklós
Rubertsson, Sten
author_sort Mälberg, Johan
collection PubMed
description INTRODUCTION: The presented study aimed to investigate whether a mechanical chest compression piston device with a suction cup assisting chest recoil could impact the hemodynamic status when compared to a bare piston during cardiopulmonary resuscitation. METHODS: 16 piglets were anesthetized and randomized into 2 groups. After 3 minutes of induced ventricular fibrillation, a LUCAS 3 device was used to perform chest compressions, in one group a suction cup was mounted on the device’s piston, while in the other group, compressions were performed by the bare piston. The device was used in 30:2 mode and the animals were manually ventilated. Endpoints of the study were: end tidal carbon dioxide, coronary and cerebral perfusion pressures, and brain oxygenation (measured using near infrared spectroscopy). At the end of the protocol, the animals that got a return to spontaneous circulation were observed for 60 minutes, then euthanized. RESULTS: No difference was found in end tidal carbon dioxide or tidal volumes. Coronary perfusion pressure and cerebral oxygenation were higher in the Suction cup group over the entire experiment time, while cerebral perfusion pressure was higher only in the last 5 minutes of CPR. A passive tidal volume (air going in and out the airways during compressions) was detected and found correlated to end tidal carbon dioxide. CONCLUSIONS: The use of a suction cup on a piston-based chest compression device did not increase end tidal carbon dioxide, but it was associated to a higher coronary perfusion pressure.
format Online
Article
Text
id pubmed-9525897
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-95258972022-10-02 Suction cup on a piston-based chest compression device improves coronary perfusion pressure and cerebral oxygenation during experimental cardiopulmonary resuscitation Mälberg, Johan Smekal, David Marchesi, Silvia Lipcsey, Miklós Rubertsson, Sten Resusc Plus Experimental Paper INTRODUCTION: The presented study aimed to investigate whether a mechanical chest compression piston device with a suction cup assisting chest recoil could impact the hemodynamic status when compared to a bare piston during cardiopulmonary resuscitation. METHODS: 16 piglets were anesthetized and randomized into 2 groups. After 3 minutes of induced ventricular fibrillation, a LUCAS 3 device was used to perform chest compressions, in one group a suction cup was mounted on the device’s piston, while in the other group, compressions were performed by the bare piston. The device was used in 30:2 mode and the animals were manually ventilated. Endpoints of the study were: end tidal carbon dioxide, coronary and cerebral perfusion pressures, and brain oxygenation (measured using near infrared spectroscopy). At the end of the protocol, the animals that got a return to spontaneous circulation were observed for 60 minutes, then euthanized. RESULTS: No difference was found in end tidal carbon dioxide or tidal volumes. Coronary perfusion pressure and cerebral oxygenation were higher in the Suction cup group over the entire experiment time, while cerebral perfusion pressure was higher only in the last 5 minutes of CPR. A passive tidal volume (air going in and out the airways during compressions) was detected and found correlated to end tidal carbon dioxide. CONCLUSIONS: The use of a suction cup on a piston-based chest compression device did not increase end tidal carbon dioxide, but it was associated to a higher coronary perfusion pressure. Elsevier 2022-09-29 /pmc/articles/PMC9525897/ /pubmed/36193235 http://dx.doi.org/10.1016/j.resplu.2022.100311 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Experimental Paper
Mälberg, Johan
Smekal, David
Marchesi, Silvia
Lipcsey, Miklós
Rubertsson, Sten
Suction cup on a piston-based chest compression device improves coronary perfusion pressure and cerebral oxygenation during experimental cardiopulmonary resuscitation
title Suction cup on a piston-based chest compression device improves coronary perfusion pressure and cerebral oxygenation during experimental cardiopulmonary resuscitation
title_full Suction cup on a piston-based chest compression device improves coronary perfusion pressure and cerebral oxygenation during experimental cardiopulmonary resuscitation
title_fullStr Suction cup on a piston-based chest compression device improves coronary perfusion pressure and cerebral oxygenation during experimental cardiopulmonary resuscitation
title_full_unstemmed Suction cup on a piston-based chest compression device improves coronary perfusion pressure and cerebral oxygenation during experimental cardiopulmonary resuscitation
title_short Suction cup on a piston-based chest compression device improves coronary perfusion pressure and cerebral oxygenation during experimental cardiopulmonary resuscitation
title_sort suction cup on a piston-based chest compression device improves coronary perfusion pressure and cerebral oxygenation during experimental cardiopulmonary resuscitation
topic Experimental Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9525897/
https://www.ncbi.nlm.nih.gov/pubmed/36193235
http://dx.doi.org/10.1016/j.resplu.2022.100311
work_keys_str_mv AT malbergjohan suctioncuponapistonbasedchestcompressiondeviceimprovescoronaryperfusionpressureandcerebraloxygenationduringexperimentalcardiopulmonaryresuscitation
AT smekaldavid suctioncuponapistonbasedchestcompressiondeviceimprovescoronaryperfusionpressureandcerebraloxygenationduringexperimentalcardiopulmonaryresuscitation
AT marchesisilvia suctioncuponapistonbasedchestcompressiondeviceimprovescoronaryperfusionpressureandcerebraloxygenationduringexperimentalcardiopulmonaryresuscitation
AT lipcseymiklos suctioncuponapistonbasedchestcompressiondeviceimprovescoronaryperfusionpressureandcerebraloxygenationduringexperimentalcardiopulmonaryresuscitation
AT rubertssonsten suctioncuponapistonbasedchestcompressiondeviceimprovescoronaryperfusionpressureandcerebraloxygenationduringexperimentalcardiopulmonaryresuscitation