Cargando…
Comparison of white-to-white measurements using four devices and their determination of ICL sizing
BACKGROUND: To compare the measurements obtained from the Orbscan II, IOLMaster 700, Pentacam AXL, and Castroviejo caliper and their effects on calculating the recommended implantable collamer lens (ICL) size and postoperative vault measurements. METHODS: This is a retrospective cross-sectional stud...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9526955/ https://www.ncbi.nlm.nih.gov/pubmed/36182955 http://dx.doi.org/10.1186/s40662-022-00308-z |
_version_ | 1784800984291082240 |
---|---|
author | Ang, Robert Edward T. Reyes, Edward Kenneth F. Ayuyao, Fernando Amado J. Umali, Maria Isabel N. Cruz, Emerson M. |
author_facet | Ang, Robert Edward T. Reyes, Edward Kenneth F. Ayuyao, Fernando Amado J. Umali, Maria Isabel N. Cruz, Emerson M. |
author_sort | Ang, Robert Edward T. |
collection | PubMed |
description | BACKGROUND: To compare the measurements obtained from the Orbscan II, IOLMaster 700, Pentacam AXL, and Castroviejo caliper and their effects on calculating the recommended implantable collamer lens (ICL) size and postoperative vault measurements. METHODS: This is a retrospective cross-sectional study of patients who underwent ICL surgery by a single surgeon from March 1, 2018 to July 31, 2021. Records were reviewed for the anterior chamber depth (ACD) and white-to-white (WTW) measurements obtained from the Orbscan II, IOLMaster 700, Pentacam AXL, and Castroviejo caliper (WTW only). These were used to calculate the recommended ICL size. The actual ICL size implanted, and vault measurements obtained one month postoperatively were also collected. RESULTS: One hundred seven eyes with a mean age of 27.9 ± 7.7 years were included in the study. Mean WTW measurements were significantly different between devices (P < 0.0001), with the IOLMaster 700 having the highest value (12.14 ± 0.04 mm) and the caliper having the lowest value (11.45 ± 0.04 mm). Mean ACD measurements were the lowest in Orbscan II (3.12 ± 0.25 mm) and the highest in Pentacam AXL (3.16 ± 0.24 mm). The Pentacam AXL produced an ICL size similar to the Orbscan in 69.2% of eyes. The IOLMaster yielded an ICL measurement one size larger than Orbscan-based calculations in 64.5% of eyes. Using the Orbscan WTW and ACD, the desired vault of 0.25 to 0.75 mm and 0.25 to 1.00 mm was achieved in 70% and 91% of eyes, respectively. Substituting caliper WTW to IOLMaster 700 or Pentacam AXL WTW increases the percentage of achieving the desired vault to 80%, similar to the Orbscan. CONCLUSIONS: The Orbscan II, IOLMaster 700, and Pentacam AXL cannot be used interchangeably for calculating ICL sizing. Combining the WTW from caliper measurement with the ACD of the IOLMaster 700 or Pentacam AXL could improve ICL sizing and achieve a higher percentage of eyes with the desired vault. |
format | Online Article Text |
id | pubmed-9526955 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-95269552022-10-03 Comparison of white-to-white measurements using four devices and their determination of ICL sizing Ang, Robert Edward T. Reyes, Edward Kenneth F. Ayuyao, Fernando Amado J. Umali, Maria Isabel N. Cruz, Emerson M. Eye Vis (Lond) Research BACKGROUND: To compare the measurements obtained from the Orbscan II, IOLMaster 700, Pentacam AXL, and Castroviejo caliper and their effects on calculating the recommended implantable collamer lens (ICL) size and postoperative vault measurements. METHODS: This is a retrospective cross-sectional study of patients who underwent ICL surgery by a single surgeon from March 1, 2018 to July 31, 2021. Records were reviewed for the anterior chamber depth (ACD) and white-to-white (WTW) measurements obtained from the Orbscan II, IOLMaster 700, Pentacam AXL, and Castroviejo caliper (WTW only). These were used to calculate the recommended ICL size. The actual ICL size implanted, and vault measurements obtained one month postoperatively were also collected. RESULTS: One hundred seven eyes with a mean age of 27.9 ± 7.7 years were included in the study. Mean WTW measurements were significantly different between devices (P < 0.0001), with the IOLMaster 700 having the highest value (12.14 ± 0.04 mm) and the caliper having the lowest value (11.45 ± 0.04 mm). Mean ACD measurements were the lowest in Orbscan II (3.12 ± 0.25 mm) and the highest in Pentacam AXL (3.16 ± 0.24 mm). The Pentacam AXL produced an ICL size similar to the Orbscan in 69.2% of eyes. The IOLMaster yielded an ICL measurement one size larger than Orbscan-based calculations in 64.5% of eyes. Using the Orbscan WTW and ACD, the desired vault of 0.25 to 0.75 mm and 0.25 to 1.00 mm was achieved in 70% and 91% of eyes, respectively. Substituting caliper WTW to IOLMaster 700 or Pentacam AXL WTW increases the percentage of achieving the desired vault to 80%, similar to the Orbscan. CONCLUSIONS: The Orbscan II, IOLMaster 700, and Pentacam AXL cannot be used interchangeably for calculating ICL sizing. Combining the WTW from caliper measurement with the ACD of the IOLMaster 700 or Pentacam AXL could improve ICL sizing and achieve a higher percentage of eyes with the desired vault. BioMed Central 2022-10-02 /pmc/articles/PMC9526955/ /pubmed/36182955 http://dx.doi.org/10.1186/s40662-022-00308-z Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Ang, Robert Edward T. Reyes, Edward Kenneth F. Ayuyao, Fernando Amado J. Umali, Maria Isabel N. Cruz, Emerson M. Comparison of white-to-white measurements using four devices and their determination of ICL sizing |
title | Comparison of white-to-white measurements using four devices and their determination of ICL sizing |
title_full | Comparison of white-to-white measurements using four devices and their determination of ICL sizing |
title_fullStr | Comparison of white-to-white measurements using four devices and their determination of ICL sizing |
title_full_unstemmed | Comparison of white-to-white measurements using four devices and their determination of ICL sizing |
title_short | Comparison of white-to-white measurements using four devices and their determination of ICL sizing |
title_sort | comparison of white-to-white measurements using four devices and their determination of icl sizing |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9526955/ https://www.ncbi.nlm.nih.gov/pubmed/36182955 http://dx.doi.org/10.1186/s40662-022-00308-z |
work_keys_str_mv | AT angrobertedwardt comparisonofwhitetowhitemeasurementsusingfourdevicesandtheirdeterminationoficlsizing AT reyesedwardkennethf comparisonofwhitetowhitemeasurementsusingfourdevicesandtheirdeterminationoficlsizing AT ayuyaofernandoamadoj comparisonofwhitetowhitemeasurementsusingfourdevicesandtheirdeterminationoficlsizing AT umalimariaisabeln comparisonofwhitetowhitemeasurementsusingfourdevicesandtheirdeterminationoficlsizing AT cruzemersonm comparisonofwhitetowhitemeasurementsusingfourdevicesandtheirdeterminationoficlsizing |