Cargando…
Radiation Protection of the Eye Lens in Fluoroscopy-guided Interventional Procedures
The medical staff involved in fluoroscopy-guided procedures are at potential risks of radiation-induced cataract. Therefore, proper monitoring of the lens doses is critical, and radiation protection should be provided to the maximum extent that is reasonably achievable. The collar dosimeter is neces...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japanese Society of Interventional Radiology
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9527101/ https://www.ncbi.nlm.nih.gov/pubmed/36196387 http://dx.doi.org/10.22575/interventionalradiology.2022-0006 |
_version_ | 1784801011525746688 |
---|---|
author | Akahane, Masaaki Yoshioka, Naoki Kiryu, Shigeru |
author_facet | Akahane, Masaaki Yoshioka, Naoki Kiryu, Shigeru |
author_sort | Akahane, Masaaki |
collection | PubMed |
description | The medical staff involved in fluoroscopy-guided procedures are at potential risks of radiation-induced cataract. Therefore, proper monitoring of the lens doses is critical, and radiation protection should be provided to the maximum extent that is reasonably achievable. The collar dosimeter is necessary to avoid underestimation of the lens dose, and the third dosimeter behind the protective eyewear would be helpful for those who are likely to exceed the dose limit. The reduction of the patient doses will correspondingly reduce the staff doses. Proper placement of the ceiling-mounted shields and minimization of the face-to-glass gap are the keys to effective shielding. The optimization of procedures and devices that help maintain a distance from the irradiated area and to prevent the looking-up posture will substantially reduce the lens dose. |
format | Online Article Text |
id | pubmed-9527101 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | The Japanese Society of Interventional Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-95271012022-10-03 Radiation Protection of the Eye Lens in Fluoroscopy-guided Interventional Procedures Akahane, Masaaki Yoshioka, Naoki Kiryu, Shigeru Interv Radiol (Higashimatsuyama) Review The medical staff involved in fluoroscopy-guided procedures are at potential risks of radiation-induced cataract. Therefore, proper monitoring of the lens doses is critical, and radiation protection should be provided to the maximum extent that is reasonably achievable. The collar dosimeter is necessary to avoid underestimation of the lens dose, and the third dosimeter behind the protective eyewear would be helpful for those who are likely to exceed the dose limit. The reduction of the patient doses will correspondingly reduce the staff doses. Proper placement of the ceiling-mounted shields and minimization of the face-to-glass gap are the keys to effective shielding. The optimization of procedures and devices that help maintain a distance from the irradiated area and to prevent the looking-up posture will substantially reduce the lens dose. The Japanese Society of Interventional Radiology 2022-07-01 /pmc/articles/PMC9527101/ /pubmed/36196387 http://dx.doi.org/10.22575/interventionalradiology.2022-0006 Text en © 2022 Japanese Society of Interventional Radiology https://creativecommons.org/licenses/by-nc/4.0/Interventional Radiology is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial 4.0 International License. To view the details of this license, please visit (https://creativecommons.org/licenses/by-nc/4.0/). |
spellingShingle | Review Akahane, Masaaki Yoshioka, Naoki Kiryu, Shigeru Radiation Protection of the Eye Lens in Fluoroscopy-guided Interventional Procedures |
title | Radiation Protection of the Eye Lens in Fluoroscopy-guided Interventional Procedures |
title_full | Radiation Protection of the Eye Lens in Fluoroscopy-guided Interventional Procedures |
title_fullStr | Radiation Protection of the Eye Lens in Fluoroscopy-guided Interventional Procedures |
title_full_unstemmed | Radiation Protection of the Eye Lens in Fluoroscopy-guided Interventional Procedures |
title_short | Radiation Protection of the Eye Lens in Fluoroscopy-guided Interventional Procedures |
title_sort | radiation protection of the eye lens in fluoroscopy-guided interventional procedures |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9527101/ https://www.ncbi.nlm.nih.gov/pubmed/36196387 http://dx.doi.org/10.22575/interventionalradiology.2022-0006 |
work_keys_str_mv | AT akahanemasaaki radiationprotectionoftheeyelensinfluoroscopyguidedinterventionalprocedures AT yoshiokanaoki radiationprotectionoftheeyelensinfluoroscopyguidedinterventionalprocedures AT kiryushigeru radiationprotectionoftheeyelensinfluoroscopyguidedinterventionalprocedures |