Cargando…
Biomechanical Comparison of Fiber Tape Device Versus Transarticular Screws for Ligamentous Lisfranc Injury in a Cadaveric Model
BACKGROUND: The preferred method of fixation and surgical treatment for ligamentous Lisfranc injuries is controversial. Transarticular screws, bridge plating, fusion, and flexible fixation have been described, yet none have demonstrated superiority. Furthermore, screw fixation and plating often requ...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9527447/ https://www.ncbi.nlm.nih.gov/pubmed/35993448 http://dx.doi.org/10.1177/03635465221118580 |
_version_ | 1784801087417483264 |
---|---|
author | Koroneos, Zachary A. Manto, Kristen M. Martinazzi, Brandon J. Stauch, Chris Bifano, Shawn M. Kunselman, Allen R. Lewis, Gregory S. Aynardi, Michael |
author_facet | Koroneos, Zachary A. Manto, Kristen M. Martinazzi, Brandon J. Stauch, Chris Bifano, Shawn M. Kunselman, Allen R. Lewis, Gregory S. Aynardi, Michael |
author_sort | Koroneos, Zachary A. |
collection | PubMed |
description | BACKGROUND: The preferred method of fixation and surgical treatment for ligamentous Lisfranc injuries is controversial. Transarticular screws, bridge plating, fusion, and flexible fixation have been described, yet none have demonstrated superiority. Furthermore, screw fixation and plating often require secondary surgery to remove implants, leading surgeons to seek alternative fixation methods. PURPOSE: To compare transarticular screws and a fiber tape construct under a spectrum of biomechanical loads by evaluating the diastasis at 3 joints in the Lisfranc complex. STUDY DESIGN: Controlled laboratory study. METHODS: Eight matched pairs of fresh, previously frozen lower extremity cadaveric specimens were fixed with either 2 cannulated transarticular crossed screws or a fiber tape construct with a supplemental intercuneiform limb. The diastasis between bones was measured at 3 midfoot joints in the Lisfranc complex: the Lisfranc articulation, the second tarsometatarsal joint, and the intercuneiform joint. Measurements were obtained for the preinjured, injured, and fixation conditions under static loading at 50% donor body weight. Specimens then underwent cyclic loading performed at 1 Hz and 100 cycles, based on 100-N stepwise increases in ground-reaction force from 100 to 2000 N, to simulate postoperative loading from the partial weightbearing stage to high-energy activities. Failure of fixation was defined as diastasis ≥2 mm at the Lisfranc articulation (second metatarsal–medial cuneiform joint). RESULTS: There were no significant differences in diastasis detected at the Lisfranc articulation or the intercuneiform joint throughout all loading cycles between groups. All specimens endured loading up to 50% body weight + 1400 N. Up to and including this stage, there were 2 failures in the cannulated transarticular crossed-screw group and none in the fiber tape group. CONCLUSION: The fiber tape construct with a supplemental intercuneiform limb, which does not require later removal, may provide comparable biomechanical stability to cannulated transarticular crossed screws, even at higher loads. CLINICAL RELEVANCE: Ligamentous Lisfranc injuries are common among athletes. Therefore, biomechanical evaluations are necessary to determine stable constructs that can limit the time to return to play. This study compares the biomechanical stability of 2 methods of fixation for ligamentous injury through a wide spectrum of loading, including those experienced by athletes. |
format | Online Article Text |
id | pubmed-9527447 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-95274472022-10-04 Biomechanical Comparison of Fiber Tape Device Versus Transarticular Screws for Ligamentous Lisfranc Injury in a Cadaveric Model Koroneos, Zachary A. Manto, Kristen M. Martinazzi, Brandon J. Stauch, Chris Bifano, Shawn M. Kunselman, Allen R. Lewis, Gregory S. Aynardi, Michael Am J Sports Med Articles BACKGROUND: The preferred method of fixation and surgical treatment for ligamentous Lisfranc injuries is controversial. Transarticular screws, bridge plating, fusion, and flexible fixation have been described, yet none have demonstrated superiority. Furthermore, screw fixation and plating often require secondary surgery to remove implants, leading surgeons to seek alternative fixation methods. PURPOSE: To compare transarticular screws and a fiber tape construct under a spectrum of biomechanical loads by evaluating the diastasis at 3 joints in the Lisfranc complex. STUDY DESIGN: Controlled laboratory study. METHODS: Eight matched pairs of fresh, previously frozen lower extremity cadaveric specimens were fixed with either 2 cannulated transarticular crossed screws or a fiber tape construct with a supplemental intercuneiform limb. The diastasis between bones was measured at 3 midfoot joints in the Lisfranc complex: the Lisfranc articulation, the second tarsometatarsal joint, and the intercuneiform joint. Measurements were obtained for the preinjured, injured, and fixation conditions under static loading at 50% donor body weight. Specimens then underwent cyclic loading performed at 1 Hz and 100 cycles, based on 100-N stepwise increases in ground-reaction force from 100 to 2000 N, to simulate postoperative loading from the partial weightbearing stage to high-energy activities. Failure of fixation was defined as diastasis ≥2 mm at the Lisfranc articulation (second metatarsal–medial cuneiform joint). RESULTS: There were no significant differences in diastasis detected at the Lisfranc articulation or the intercuneiform joint throughout all loading cycles between groups. All specimens endured loading up to 50% body weight + 1400 N. Up to and including this stage, there were 2 failures in the cannulated transarticular crossed-screw group and none in the fiber tape group. CONCLUSION: The fiber tape construct with a supplemental intercuneiform limb, which does not require later removal, may provide comparable biomechanical stability to cannulated transarticular crossed screws, even at higher loads. CLINICAL RELEVANCE: Ligamentous Lisfranc injuries are common among athletes. Therefore, biomechanical evaluations are necessary to determine stable constructs that can limit the time to return to play. This study compares the biomechanical stability of 2 methods of fixation for ligamentous injury through a wide spectrum of loading, including those experienced by athletes. SAGE Publications 2022-08-22 2022-10 /pmc/articles/PMC9527447/ /pubmed/35993448 http://dx.doi.org/10.1177/03635465221118580 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by/4.0/This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Articles Koroneos, Zachary A. Manto, Kristen M. Martinazzi, Brandon J. Stauch, Chris Bifano, Shawn M. Kunselman, Allen R. Lewis, Gregory S. Aynardi, Michael Biomechanical Comparison of Fiber Tape Device Versus Transarticular Screws for Ligamentous Lisfranc Injury in a Cadaveric Model |
title | Biomechanical Comparison of Fiber Tape Device Versus Transarticular Screws for Ligamentous Lisfranc Injury in a Cadaveric Model |
title_full | Biomechanical Comparison of Fiber Tape Device Versus Transarticular Screws for Ligamentous Lisfranc Injury in a Cadaveric Model |
title_fullStr | Biomechanical Comparison of Fiber Tape Device Versus Transarticular Screws for Ligamentous Lisfranc Injury in a Cadaveric Model |
title_full_unstemmed | Biomechanical Comparison of Fiber Tape Device Versus Transarticular Screws for Ligamentous Lisfranc Injury in a Cadaveric Model |
title_short | Biomechanical Comparison of Fiber Tape Device Versus Transarticular Screws for Ligamentous Lisfranc Injury in a Cadaveric Model |
title_sort | biomechanical comparison of fiber tape device versus transarticular screws for ligamentous lisfranc injury in a cadaveric model |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9527447/ https://www.ncbi.nlm.nih.gov/pubmed/35993448 http://dx.doi.org/10.1177/03635465221118580 |
work_keys_str_mv | AT koroneoszacharya biomechanicalcomparisonoffibertapedeviceversustransarticularscrewsforligamentouslisfrancinjuryinacadavericmodel AT mantokristenm biomechanicalcomparisonoffibertapedeviceversustransarticularscrewsforligamentouslisfrancinjuryinacadavericmodel AT martinazzibrandonj biomechanicalcomparisonoffibertapedeviceversustransarticularscrewsforligamentouslisfrancinjuryinacadavericmodel AT stauchchris biomechanicalcomparisonoffibertapedeviceversustransarticularscrewsforligamentouslisfrancinjuryinacadavericmodel AT bifanoshawnm biomechanicalcomparisonoffibertapedeviceversustransarticularscrewsforligamentouslisfrancinjuryinacadavericmodel AT kunselmanallenr biomechanicalcomparisonoffibertapedeviceversustransarticularscrewsforligamentouslisfrancinjuryinacadavericmodel AT lewisgregorys biomechanicalcomparisonoffibertapedeviceversustransarticularscrewsforligamentouslisfrancinjuryinacadavericmodel AT aynardimichael biomechanicalcomparisonoffibertapedeviceversustransarticularscrewsforligamentouslisfrancinjuryinacadavericmodel |