Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants
PURPOSE: The aim of this study was to assess the influence of kilovoltage-peak (kVp) and the metal artifact reduction (MAR) tool on the detection of buccal and lingual peri-implant dehiscence in the presence of titanium-zirconia (Ti-Zr) and zirconia (Zr) implants in cone-beam computed tomography (CB...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Oral and Maxillofacial Radiology
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9530290/ https://www.ncbi.nlm.nih.gov/pubmed/36238703 http://dx.doi.org/10.5624/isd.20220040 |
_version_ | 1784801648137207808 |
---|---|
author | Fontenele, Rocharles Cavalcante Nascimento, Eduarda Helena Leandro Imbelloni-Vasconcelos, Ana Catarina Martins, Luciano Augusto Cano Pontual, Andrea dos Anjos Ramos-Perez, Flávia Maria Moraes Freitas, Deborah Queiroz |
author_facet | Fontenele, Rocharles Cavalcante Nascimento, Eduarda Helena Leandro Imbelloni-Vasconcelos, Ana Catarina Martins, Luciano Augusto Cano Pontual, Andrea dos Anjos Ramos-Perez, Flávia Maria Moraes Freitas, Deborah Queiroz |
author_sort | Fontenele, Rocharles Cavalcante |
collection | PubMed |
description | PURPOSE: The aim of this study was to assess the influence of kilovoltage-peak (kVp) and the metal artifact reduction (MAR) tool on the detection of buccal and lingual peri-implant dehiscence in the presence of titanium-zirconia (Ti-Zr) and zirconia (Zr) implants in cone-beam computed tomography (CBCT) images. MATERIALS AND METHODS: Twenty implant sites were created in the posterior region of human mandibles, including control sites (without dehiscence) and experimental sites (with dehiscence). Individually, a Ti-Zr or Zr implant was placed in each implant site. CBCT scans were performed using a Picasso Trio device, with variation in the kVp setting (70 or 90 kVp) and whether the MAR tool was used. Three oral radiologists scored the detection of dehiscence using a 5-point scale. The area under the receiver operating characteristic (ROC) curve, sensitivity, and specificity were calculated and compared by multi-way analysis of variance (α=0.05). RESULTS: The kVp, cortical plate involved (buccal or lingual cortices), and MAR did not influence any diagnostic values (P>0.05). The material of the implant did not influence the ROC curve values (P>0.05). In contrast, the sensitivity and specificity were statistically significantly influenced by the implant material (P<0.05) with Zr implants showing higher sensitivity values and lower specificity values than Ti-Zr implants. CONCLUSION: The detection of peri-implant dehiscence was not influenced by kVp, use of the MAR tool, or the cortical plate. Greater sensitivity and lower specificity were shown for the detection of peri-implant dehiscence in the presence of a Zr implant. |
format | Online Article Text |
id | pubmed-9530290 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Korean Academy of Oral and Maxillofacial Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-95302902022-10-12 Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants Fontenele, Rocharles Cavalcante Nascimento, Eduarda Helena Leandro Imbelloni-Vasconcelos, Ana Catarina Martins, Luciano Augusto Cano Pontual, Andrea dos Anjos Ramos-Perez, Flávia Maria Moraes Freitas, Deborah Queiroz Imaging Sci Dent Original Article PURPOSE: The aim of this study was to assess the influence of kilovoltage-peak (kVp) and the metal artifact reduction (MAR) tool on the detection of buccal and lingual peri-implant dehiscence in the presence of titanium-zirconia (Ti-Zr) and zirconia (Zr) implants in cone-beam computed tomography (CBCT) images. MATERIALS AND METHODS: Twenty implant sites were created in the posterior region of human mandibles, including control sites (without dehiscence) and experimental sites (with dehiscence). Individually, a Ti-Zr or Zr implant was placed in each implant site. CBCT scans were performed using a Picasso Trio device, with variation in the kVp setting (70 or 90 kVp) and whether the MAR tool was used. Three oral radiologists scored the detection of dehiscence using a 5-point scale. The area under the receiver operating characteristic (ROC) curve, sensitivity, and specificity were calculated and compared by multi-way analysis of variance (α=0.05). RESULTS: The kVp, cortical plate involved (buccal or lingual cortices), and MAR did not influence any diagnostic values (P>0.05). The material of the implant did not influence the ROC curve values (P>0.05). In contrast, the sensitivity and specificity were statistically significantly influenced by the implant material (P<0.05) with Zr implants showing higher sensitivity values and lower specificity values than Ti-Zr implants. CONCLUSION: The detection of peri-implant dehiscence was not influenced by kVp, use of the MAR tool, or the cortical plate. Greater sensitivity and lower specificity were shown for the detection of peri-implant dehiscence in the presence of a Zr implant. Korean Academy of Oral and Maxillofacial Radiology 2022-09 2022-07-05 /pmc/articles/PMC9530290/ /pubmed/36238703 http://dx.doi.org/10.5624/isd.20220040 Text en Copyright © 2022 by Korean Academy of Oral and Maxillofacial Radiology https://creativecommons.org/licenses/by-nc/3.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0 (https://creativecommons.org/licenses/by-nc/3.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Fontenele, Rocharles Cavalcante Nascimento, Eduarda Helena Leandro Imbelloni-Vasconcelos, Ana Catarina Martins, Luciano Augusto Cano Pontual, Andrea dos Anjos Ramos-Perez, Flávia Maria Moraes Freitas, Deborah Queiroz Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants |
title | Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants |
title_full | Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants |
title_fullStr | Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants |
title_full_unstemmed | Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants |
title_short | Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants |
title_sort | influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9530290/ https://www.ncbi.nlm.nih.gov/pubmed/36238703 http://dx.doi.org/10.5624/isd.20220040 |
work_keys_str_mv | AT fontenelerocharlescavalcante influenceofkilovoltagepeakandthemetalartifactreductiontoolinconebeamcomputedtomographyonthedetectionofbonedefectsaroundtitaniumzirconiaandzirconiaimplants AT nascimentoeduardahelenaleandro influenceofkilovoltagepeakandthemetalartifactreductiontoolinconebeamcomputedtomographyonthedetectionofbonedefectsaroundtitaniumzirconiaandzirconiaimplants AT imbellonivasconcelosanacatarina influenceofkilovoltagepeakandthemetalartifactreductiontoolinconebeamcomputedtomographyonthedetectionofbonedefectsaroundtitaniumzirconiaandzirconiaimplants AT martinslucianoaugustocano influenceofkilovoltagepeakandthemetalartifactreductiontoolinconebeamcomputedtomographyonthedetectionofbonedefectsaroundtitaniumzirconiaandzirconiaimplants AT pontualandreadosanjos influenceofkilovoltagepeakandthemetalartifactreductiontoolinconebeamcomputedtomographyonthedetectionofbonedefectsaroundtitaniumzirconiaandzirconiaimplants AT ramosperezflaviamariamoraes influenceofkilovoltagepeakandthemetalartifactreductiontoolinconebeamcomputedtomographyonthedetectionofbonedefectsaroundtitaniumzirconiaandzirconiaimplants AT freitasdeborahqueiroz influenceofkilovoltagepeakandthemetalartifactreductiontoolinconebeamcomputedtomographyonthedetectionofbonedefectsaroundtitaniumzirconiaandzirconiaimplants |