Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants

PURPOSE: The aim of this study was to assess the influence of kilovoltage-peak (kVp) and the metal artifact reduction (MAR) tool on the detection of buccal and lingual peri-implant dehiscence in the presence of titanium-zirconia (Ti-Zr) and zirconia (Zr) implants in cone-beam computed tomography (CB...

Descripción completa

Detalles Bibliográficos
Autores principales: Fontenele, Rocharles Cavalcante, Nascimento, Eduarda Helena Leandro, Imbelloni-Vasconcelos, Ana Catarina, Martins, Luciano Augusto Cano, Pontual, Andrea dos Anjos, Ramos-Perez, Flávia Maria Moraes, Freitas, Deborah Queiroz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Oral and Maxillofacial Radiology 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9530290/
https://www.ncbi.nlm.nih.gov/pubmed/36238703
http://dx.doi.org/10.5624/isd.20220040
_version_ 1784801648137207808
author Fontenele, Rocharles Cavalcante
Nascimento, Eduarda Helena Leandro
Imbelloni-Vasconcelos, Ana Catarina
Martins, Luciano Augusto Cano
Pontual, Andrea dos Anjos
Ramos-Perez, Flávia Maria Moraes
Freitas, Deborah Queiroz
author_facet Fontenele, Rocharles Cavalcante
Nascimento, Eduarda Helena Leandro
Imbelloni-Vasconcelos, Ana Catarina
Martins, Luciano Augusto Cano
Pontual, Andrea dos Anjos
Ramos-Perez, Flávia Maria Moraes
Freitas, Deborah Queiroz
author_sort Fontenele, Rocharles Cavalcante
collection PubMed
description PURPOSE: The aim of this study was to assess the influence of kilovoltage-peak (kVp) and the metal artifact reduction (MAR) tool on the detection of buccal and lingual peri-implant dehiscence in the presence of titanium-zirconia (Ti-Zr) and zirconia (Zr) implants in cone-beam computed tomography (CBCT) images. MATERIALS AND METHODS: Twenty implant sites were created in the posterior region of human mandibles, including control sites (without dehiscence) and experimental sites (with dehiscence). Individually, a Ti-Zr or Zr implant was placed in each implant site. CBCT scans were performed using a Picasso Trio device, with variation in the kVp setting (70 or 90 kVp) and whether the MAR tool was used. Three oral radiologists scored the detection of dehiscence using a 5-point scale. The area under the receiver operating characteristic (ROC) curve, sensitivity, and specificity were calculated and compared by multi-way analysis of variance (α=0.05). RESULTS: The kVp, cortical plate involved (buccal or lingual cortices), and MAR did not influence any diagnostic values (P>0.05). The material of the implant did not influence the ROC curve values (P>0.05). In contrast, the sensitivity and specificity were statistically significantly influenced by the implant material (P<0.05) with Zr implants showing higher sensitivity values and lower specificity values than Ti-Zr implants. CONCLUSION: The detection of peri-implant dehiscence was not influenced by kVp, use of the MAR tool, or the cortical plate. Greater sensitivity and lower specificity were shown for the detection of peri-implant dehiscence in the presence of a Zr implant.
format Online
Article
Text
id pubmed-9530290
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Korean Academy of Oral and Maxillofacial Radiology
record_format MEDLINE/PubMed
spelling pubmed-95302902022-10-12 Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants Fontenele, Rocharles Cavalcante Nascimento, Eduarda Helena Leandro Imbelloni-Vasconcelos, Ana Catarina Martins, Luciano Augusto Cano Pontual, Andrea dos Anjos Ramos-Perez, Flávia Maria Moraes Freitas, Deborah Queiroz Imaging Sci Dent Original Article PURPOSE: The aim of this study was to assess the influence of kilovoltage-peak (kVp) and the metal artifact reduction (MAR) tool on the detection of buccal and lingual peri-implant dehiscence in the presence of titanium-zirconia (Ti-Zr) and zirconia (Zr) implants in cone-beam computed tomography (CBCT) images. MATERIALS AND METHODS: Twenty implant sites were created in the posterior region of human mandibles, including control sites (without dehiscence) and experimental sites (with dehiscence). Individually, a Ti-Zr or Zr implant was placed in each implant site. CBCT scans were performed using a Picasso Trio device, with variation in the kVp setting (70 or 90 kVp) and whether the MAR tool was used. Three oral radiologists scored the detection of dehiscence using a 5-point scale. The area under the receiver operating characteristic (ROC) curve, sensitivity, and specificity were calculated and compared by multi-way analysis of variance (α=0.05). RESULTS: The kVp, cortical plate involved (buccal or lingual cortices), and MAR did not influence any diagnostic values (P>0.05). The material of the implant did not influence the ROC curve values (P>0.05). In contrast, the sensitivity and specificity were statistically significantly influenced by the implant material (P<0.05) with Zr implants showing higher sensitivity values and lower specificity values than Ti-Zr implants. CONCLUSION: The detection of peri-implant dehiscence was not influenced by kVp, use of the MAR tool, or the cortical plate. Greater sensitivity and lower specificity were shown for the detection of peri-implant dehiscence in the presence of a Zr implant. Korean Academy of Oral and Maxillofacial Radiology 2022-09 2022-07-05 /pmc/articles/PMC9530290/ /pubmed/36238703 http://dx.doi.org/10.5624/isd.20220040 Text en Copyright © 2022 by Korean Academy of Oral and Maxillofacial Radiology https://creativecommons.org/licenses/by-nc/3.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0 (https://creativecommons.org/licenses/by-nc/3.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Fontenele, Rocharles Cavalcante
Nascimento, Eduarda Helena Leandro
Imbelloni-Vasconcelos, Ana Catarina
Martins, Luciano Augusto Cano
Pontual, Andrea dos Anjos
Ramos-Perez, Flávia Maria Moraes
Freitas, Deborah Queiroz
Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants
title Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants
title_full Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants
title_fullStr Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants
title_full_unstemmed Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants
title_short Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants
title_sort influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9530290/
https://www.ncbi.nlm.nih.gov/pubmed/36238703
http://dx.doi.org/10.5624/isd.20220040
work_keys_str_mv AT fontenelerocharlescavalcante influenceofkilovoltagepeakandthemetalartifactreductiontoolinconebeamcomputedtomographyonthedetectionofbonedefectsaroundtitaniumzirconiaandzirconiaimplants
AT nascimentoeduardahelenaleandro influenceofkilovoltagepeakandthemetalartifactreductiontoolinconebeamcomputedtomographyonthedetectionofbonedefectsaroundtitaniumzirconiaandzirconiaimplants
AT imbellonivasconcelosanacatarina influenceofkilovoltagepeakandthemetalartifactreductiontoolinconebeamcomputedtomographyonthedetectionofbonedefectsaroundtitaniumzirconiaandzirconiaimplants
AT martinslucianoaugustocano influenceofkilovoltagepeakandthemetalartifactreductiontoolinconebeamcomputedtomographyonthedetectionofbonedefectsaroundtitaniumzirconiaandzirconiaimplants
AT pontualandreadosanjos influenceofkilovoltagepeakandthemetalartifactreductiontoolinconebeamcomputedtomographyonthedetectionofbonedefectsaroundtitaniumzirconiaandzirconiaimplants
AT ramosperezflaviamariamoraes influenceofkilovoltagepeakandthemetalartifactreductiontoolinconebeamcomputedtomographyonthedetectionofbonedefectsaroundtitaniumzirconiaandzirconiaimplants
AT freitasdeborahqueiroz influenceofkilovoltagepeakandthemetalartifactreductiontoolinconebeamcomputedtomographyonthedetectionofbonedefectsaroundtitaniumzirconiaandzirconiaimplants