Cargando…

Plate fixation of the anterior pelvic ring in patients with fragility fractures of the pelvis

INTRODUCTION: In fragility fractures of the pelvis (FFP), fractures of the posterior pelvic ring are nearly always combined with fractures of the anterior pelvic ring. When a surgical stabilization of the posterior pelvis is performed, a stabilization of the anterior pelvis is recommended as well. I...

Descripción completa

Detalles Bibliográficos
Autores principales: Herteleer, Michiel, Boudissa, Mehdi, Hofmann, Alexander, Wagner, Daniel, Rommens, Pol Maria
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9532279/
https://www.ncbi.nlm.nih.gov/pubmed/33693977
http://dx.doi.org/10.1007/s00068-021-01625-z
_version_ 1784802086702022656
author Herteleer, Michiel
Boudissa, Mehdi
Hofmann, Alexander
Wagner, Daniel
Rommens, Pol Maria
author_facet Herteleer, Michiel
Boudissa, Mehdi
Hofmann, Alexander
Wagner, Daniel
Rommens, Pol Maria
author_sort Herteleer, Michiel
collection PubMed
description INTRODUCTION: In fragility fractures of the pelvis (FFP), fractures of the posterior pelvic ring are nearly always combined with fractures of the anterior pelvic ring. When a surgical stabilization of the posterior pelvis is performed, a stabilization of the anterior pelvis is recommended as well. In this study, we aim at finding out whether conventional plate osteosynthesis is a valid option in patients with osteoporotic bone. MATERIALS AND METHODS: We retrospectively reviewed medical charts and radiographs of all patients with a FFP, who underwent a plate osteosynthesis of the anterior pelvic ring between 2009 and 2019. Patient demographics, fracture characteristics, properties of the osteosynthesis, complications and revision surgeries were documented. Single plate osteosynthesis (SPO) at the pelvic brim was compared with double plate osteosynthesis (DPO) with one plate at the pelvic brim and one plate anteriorly. We hypothesized that the number and severity of screw loosening (SL) or plate breakage in DPO are lower than in SPO. RESULTS: 48 patients with a mean age of 76.8 years were reviewed. In 37 cases, SPO was performed, in 11 cases DPO. Eight out of 11 DPO were performed in patients with FFP type III or FFP type IV. We performed significantly more DPO when the instability was located at the level of the pubic symphysis (p = 0.025). More patients with a chronic FFP (surgery more than one month after diagnosis) were treated with DPO (p = 0.07). Infra-acetabular screws were more often inserted in DPO (p = 0.056). Screw loosening (SL) was seen in the superior plate in 45% of patients. There was no SL in the anterior plate. There was SL in 19 of 37 patients with SPO and in 3 of 11 patients with DPO (p = 0.16). SL was localized near to the pubic symphysis in 19 of 22 patients after SPO and in all three patients after DPO. There was no SL in DPO within the first month postoperatively. We performed revision osteosynthesis in six patients (6/48), all belonged to the SPO group (6/37). The presence of a bone defect, unilateral or bilateral anterior pelvic ring fracture, post-operative weight-bearing restrictions, osteosynthesis of the posterior pelvic ring, and the presence of infra- or supra-acetabular screws did not significantly influence screw loosening in SPO or DPO. CONCLUSION: There is a high rate of SL in plate fixation of the anterior pelvic ring in FFP. In the vast majority, SL is located near to the pubic symphysis. DPO is associated with a lower rate of SL, less severe SL and a later onset of SL. Revision surgery is less likely in DPO. In FFP, we recommend DPO instead of SPO for fixation of fractures of the anterior pelvic ring, which are located in or near to the pubic symphysis.
format Online
Article
Text
id pubmed-9532279
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-95322792022-10-06 Plate fixation of the anterior pelvic ring in patients with fragility fractures of the pelvis Herteleer, Michiel Boudissa, Mehdi Hofmann, Alexander Wagner, Daniel Rommens, Pol Maria Eur J Trauma Emerg Surg Original Article INTRODUCTION: In fragility fractures of the pelvis (FFP), fractures of the posterior pelvic ring are nearly always combined with fractures of the anterior pelvic ring. When a surgical stabilization of the posterior pelvis is performed, a stabilization of the anterior pelvis is recommended as well. In this study, we aim at finding out whether conventional plate osteosynthesis is a valid option in patients with osteoporotic bone. MATERIALS AND METHODS: We retrospectively reviewed medical charts and radiographs of all patients with a FFP, who underwent a plate osteosynthesis of the anterior pelvic ring between 2009 and 2019. Patient demographics, fracture characteristics, properties of the osteosynthesis, complications and revision surgeries were documented. Single plate osteosynthesis (SPO) at the pelvic brim was compared with double plate osteosynthesis (DPO) with one plate at the pelvic brim and one plate anteriorly. We hypothesized that the number and severity of screw loosening (SL) or plate breakage in DPO are lower than in SPO. RESULTS: 48 patients with a mean age of 76.8 years were reviewed. In 37 cases, SPO was performed, in 11 cases DPO. Eight out of 11 DPO were performed in patients with FFP type III or FFP type IV. We performed significantly more DPO when the instability was located at the level of the pubic symphysis (p = 0.025). More patients with a chronic FFP (surgery more than one month after diagnosis) were treated with DPO (p = 0.07). Infra-acetabular screws were more often inserted in DPO (p = 0.056). Screw loosening (SL) was seen in the superior plate in 45% of patients. There was no SL in the anterior plate. There was SL in 19 of 37 patients with SPO and in 3 of 11 patients with DPO (p = 0.16). SL was localized near to the pubic symphysis in 19 of 22 patients after SPO and in all three patients after DPO. There was no SL in DPO within the first month postoperatively. We performed revision osteosynthesis in six patients (6/48), all belonged to the SPO group (6/37). The presence of a bone defect, unilateral or bilateral anterior pelvic ring fracture, post-operative weight-bearing restrictions, osteosynthesis of the posterior pelvic ring, and the presence of infra- or supra-acetabular screws did not significantly influence screw loosening in SPO or DPO. CONCLUSION: There is a high rate of SL in plate fixation of the anterior pelvic ring in FFP. In the vast majority, SL is located near to the pubic symphysis. DPO is associated with a lower rate of SL, less severe SL and a later onset of SL. Revision surgery is less likely in DPO. In FFP, we recommend DPO instead of SPO for fixation of fractures of the anterior pelvic ring, which are located in or near to the pubic symphysis. Springer Berlin Heidelberg 2021-03-11 2022 /pmc/articles/PMC9532279/ /pubmed/33693977 http://dx.doi.org/10.1007/s00068-021-01625-z Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Herteleer, Michiel
Boudissa, Mehdi
Hofmann, Alexander
Wagner, Daniel
Rommens, Pol Maria
Plate fixation of the anterior pelvic ring in patients with fragility fractures of the pelvis
title Plate fixation of the anterior pelvic ring in patients with fragility fractures of the pelvis
title_full Plate fixation of the anterior pelvic ring in patients with fragility fractures of the pelvis
title_fullStr Plate fixation of the anterior pelvic ring in patients with fragility fractures of the pelvis
title_full_unstemmed Plate fixation of the anterior pelvic ring in patients with fragility fractures of the pelvis
title_short Plate fixation of the anterior pelvic ring in patients with fragility fractures of the pelvis
title_sort plate fixation of the anterior pelvic ring in patients with fragility fractures of the pelvis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9532279/
https://www.ncbi.nlm.nih.gov/pubmed/33693977
http://dx.doi.org/10.1007/s00068-021-01625-z
work_keys_str_mv AT herteleermichiel platefixationoftheanteriorpelvicringinpatientswithfragilityfracturesofthepelvis
AT boudissamehdi platefixationoftheanteriorpelvicringinpatientswithfragilityfracturesofthepelvis
AT hofmannalexander platefixationoftheanteriorpelvicringinpatientswithfragilityfracturesofthepelvis
AT wagnerdaniel platefixationoftheanteriorpelvicringinpatientswithfragilityfracturesofthepelvis
AT rommenspolmaria platefixationoftheanteriorpelvicringinpatientswithfragilityfracturesofthepelvis