Cargando…

The effect of an infra-acetabular screw for anatomically shaped three-dimensional plate or standard plate designs in acetabulum fractures: a biomechanical analysis

BACKGROUND: Various plate shapes and implant configurations are used for stabilization of acetabulum fractures via anterior approaches. Little is known about the biomechanical stability of a two-dimensionally shaped “conventional” plate (“J-Plate”—JP) in comparison to three-dimensionally shaped plat...

Descripción completa

Detalles Bibliográficos
Autores principales: Graul, I., Marintschev, I., Pizanis, A., Herath, S. C., Pohlemann, T., Fritz, T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9532306/
https://www.ncbi.nlm.nih.gov/pubmed/34618166
http://dx.doi.org/10.1007/s00068-021-01805-x
_version_ 1784802093495746560
author Graul, I.
Marintschev, I.
Pizanis, A.
Herath, S. C.
Pohlemann, T.
Fritz, T.
author_facet Graul, I.
Marintschev, I.
Pizanis, A.
Herath, S. C.
Pohlemann, T.
Fritz, T.
author_sort Graul, I.
collection PubMed
description BACKGROUND: Various plate shapes and implant configurations are used for stabilization of acetabulum fractures via anterior approaches. Little is known about the biomechanical stability of a two-dimensionally shaped “conventional” plate (“J-Plate”—JP) in comparison to three-dimensionally shaped plate configurations (3DP). In addition, the augmentary effect of an infra-acetabular lag-screw (IACS) fixation for anterior column and posterior hemi-transverse acetabulum fractures has not been clarified in comparison of JP and 3DP constructs. This study analyzed the difference between the biomechanical stability of JP compared to 3DP and the role of an IACS in a standardized acetabular fracture model in a single-leg stance loading configuration. METHODS: In an artificial bone substitute pelvis model (Synbone(©) Malans, Switzerland), a typical and standardized fracture pattern (anterior column and posterior hemi-transverse) was created with osteotomy jigs. After anatomic reduction the stabilization was performed using JP or 3DP. Eight pelvises per group were axially loaded in a single-leg stance model up to 400 N. After the load cycle, an additional infra-acetabular screw was placed and the measurement repeated. Fragment displacement was recorded by an optical tracking system (Optitrack Prime 13®, Corvallis, USA). RESULTS: In the pure placement, 3DP provided significantly superior stability when compared to JP. Augmentation of JP by IACS increased the stability significantly, up to the level of 3DP alone, whereas augmentation of the 3DP did not result in further increase of overall stability. CONCLUSION: The anatomically shaped plate alone provides a superior biomechanical stability in fixation of an anterior column and posterior hemi-transverse fracture model. In a JP fixation the augmentation by IACS provides similar strength as the anatomically shaped 3DP. By use of the anatomically shaped 3DP the need of a clinically risky application of IACS might be avoidable. LEVEL OF EVIDENCE: IV, Experimental study.
format Online
Article
Text
id pubmed-9532306
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-95323062022-10-06 The effect of an infra-acetabular screw for anatomically shaped three-dimensional plate or standard plate designs in acetabulum fractures: a biomechanical analysis Graul, I. Marintschev, I. Pizanis, A. Herath, S. C. Pohlemann, T. Fritz, T. Eur J Trauma Emerg Surg Original Article BACKGROUND: Various plate shapes and implant configurations are used for stabilization of acetabulum fractures via anterior approaches. Little is known about the biomechanical stability of a two-dimensionally shaped “conventional” plate (“J-Plate”—JP) in comparison to three-dimensionally shaped plate configurations (3DP). In addition, the augmentary effect of an infra-acetabular lag-screw (IACS) fixation for anterior column and posterior hemi-transverse acetabulum fractures has not been clarified in comparison of JP and 3DP constructs. This study analyzed the difference between the biomechanical stability of JP compared to 3DP and the role of an IACS in a standardized acetabular fracture model in a single-leg stance loading configuration. METHODS: In an artificial bone substitute pelvis model (Synbone(©) Malans, Switzerland), a typical and standardized fracture pattern (anterior column and posterior hemi-transverse) was created with osteotomy jigs. After anatomic reduction the stabilization was performed using JP or 3DP. Eight pelvises per group were axially loaded in a single-leg stance model up to 400 N. After the load cycle, an additional infra-acetabular screw was placed and the measurement repeated. Fragment displacement was recorded by an optical tracking system (Optitrack Prime 13®, Corvallis, USA). RESULTS: In the pure placement, 3DP provided significantly superior stability when compared to JP. Augmentation of JP by IACS increased the stability significantly, up to the level of 3DP alone, whereas augmentation of the 3DP did not result in further increase of overall stability. CONCLUSION: The anatomically shaped plate alone provides a superior biomechanical stability in fixation of an anterior column and posterior hemi-transverse fracture model. In a JP fixation the augmentation by IACS provides similar strength as the anatomically shaped 3DP. By use of the anatomically shaped 3DP the need of a clinically risky application of IACS might be avoidable. LEVEL OF EVIDENCE: IV, Experimental study. Springer Berlin Heidelberg 2021-10-07 2022 /pmc/articles/PMC9532306/ /pubmed/34618166 http://dx.doi.org/10.1007/s00068-021-01805-x Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Graul, I.
Marintschev, I.
Pizanis, A.
Herath, S. C.
Pohlemann, T.
Fritz, T.
The effect of an infra-acetabular screw for anatomically shaped three-dimensional plate or standard plate designs in acetabulum fractures: a biomechanical analysis
title The effect of an infra-acetabular screw for anatomically shaped three-dimensional plate or standard plate designs in acetabulum fractures: a biomechanical analysis
title_full The effect of an infra-acetabular screw for anatomically shaped three-dimensional plate or standard plate designs in acetabulum fractures: a biomechanical analysis
title_fullStr The effect of an infra-acetabular screw for anatomically shaped three-dimensional plate or standard plate designs in acetabulum fractures: a biomechanical analysis
title_full_unstemmed The effect of an infra-acetabular screw for anatomically shaped three-dimensional plate or standard plate designs in acetabulum fractures: a biomechanical analysis
title_short The effect of an infra-acetabular screw for anatomically shaped three-dimensional plate or standard plate designs in acetabulum fractures: a biomechanical analysis
title_sort effect of an infra-acetabular screw for anatomically shaped three-dimensional plate or standard plate designs in acetabulum fractures: a biomechanical analysis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9532306/
https://www.ncbi.nlm.nih.gov/pubmed/34618166
http://dx.doi.org/10.1007/s00068-021-01805-x
work_keys_str_mv AT grauli theeffectofaninfraacetabularscrewforanatomicallyshapedthreedimensionalplateorstandardplatedesignsinacetabulumfracturesabiomechanicalanalysis
AT marintschevi theeffectofaninfraacetabularscrewforanatomicallyshapedthreedimensionalplateorstandardplatedesignsinacetabulumfracturesabiomechanicalanalysis
AT pizanisa theeffectofaninfraacetabularscrewforanatomicallyshapedthreedimensionalplateorstandardplatedesignsinacetabulumfracturesabiomechanicalanalysis
AT herathsc theeffectofaninfraacetabularscrewforanatomicallyshapedthreedimensionalplateorstandardplatedesignsinacetabulumfracturesabiomechanicalanalysis
AT pohlemannt theeffectofaninfraacetabularscrewforanatomicallyshapedthreedimensionalplateorstandardplatedesignsinacetabulumfracturesabiomechanicalanalysis
AT fritzt theeffectofaninfraacetabularscrewforanatomicallyshapedthreedimensionalplateorstandardplatedesignsinacetabulumfracturesabiomechanicalanalysis
AT grauli effectofaninfraacetabularscrewforanatomicallyshapedthreedimensionalplateorstandardplatedesignsinacetabulumfracturesabiomechanicalanalysis
AT marintschevi effectofaninfraacetabularscrewforanatomicallyshapedthreedimensionalplateorstandardplatedesignsinacetabulumfracturesabiomechanicalanalysis
AT pizanisa effectofaninfraacetabularscrewforanatomicallyshapedthreedimensionalplateorstandardplatedesignsinacetabulumfracturesabiomechanicalanalysis
AT herathsc effectofaninfraacetabularscrewforanatomicallyshapedthreedimensionalplateorstandardplatedesignsinacetabulumfracturesabiomechanicalanalysis
AT pohlemannt effectofaninfraacetabularscrewforanatomicallyshapedthreedimensionalplateorstandardplatedesignsinacetabulumfracturesabiomechanicalanalysis
AT fritzt effectofaninfraacetabularscrewforanatomicallyshapedthreedimensionalplateorstandardplatedesignsinacetabulumfracturesabiomechanicalanalysis