Cargando…
Comparison of the clinical effects of intermittently scanned and real‐time continuous glucose monitoring in children and adolescents with type 1 diabetes: A retrospective cohort study
AIMS/INTRODUCTION: The aim of the study was to compare two continuous glucose monitoring (CGM) systems, intermittently scanned CGM (isCGM) and real‐time CGM (rtCGM), to determine which system achieved better glycemic control in pediatric patients. MATERIALS AND METHODS: We carried out a retrospectiv...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9533045/ https://www.ncbi.nlm.nih.gov/pubmed/35532954 http://dx.doi.org/10.1111/jdi.13830 |
_version_ | 1784802256521003008 |
---|---|
author | Urakami, Tatsuhiko Terada, Hiroki Yoshida, Kei Kuwabara, Remi Mine, Yusuke Aoki, Masako Shoji, Yasuko Suzuki, Junichi Morioka, Ichiro |
author_facet | Urakami, Tatsuhiko Terada, Hiroki Yoshida, Kei Kuwabara, Remi Mine, Yusuke Aoki, Masako Shoji, Yasuko Suzuki, Junichi Morioka, Ichiro |
author_sort | Urakami, Tatsuhiko |
collection | PubMed |
description | AIMS/INTRODUCTION: The aim of the study was to compare two continuous glucose monitoring (CGM) systems, intermittently scanned CGM (isCGM) and real‐time CGM (rtCGM), to determine which system achieved better glycemic control in pediatric patients. MATERIALS AND METHODS: We carried out a retrospective cohort study of children and adolescents with type 1 diabetes, and compared the time in range (70–180 mg/dL), time below range (<70 mg/dL) and time above range (>180 mg/dL), and estimated glycated hemoglobin levels between patients on isCGM and rtCGM. RESULTS: Of the 112 participants, 76 (67.9%) used isCGM and 36 (32.1%) used rtCGM for glycemic management. Patients on rtCGM had significantly greater time in range (57.7 ± 12.3% vs 52.3 ± 12.3%, P = 0.0368), and had significantly lower time below range (4.3 ± 2.7% vs 10.2% ± 5.4%, P < 0.001) than those on isCGM, but there was no significant difference in the time above range (37.4 ± 12.9% vs 38.0% ± 12.5%, P = 0.881) or the glycosylated hemoglobin A1c levels (7.4 ± 0.9% vs 7.5 ± 0.8%, P = 0.734) between the two groups. CONCLUSIONS: Pediatric patients with type 1 diabetes on rtCGM also showed more beneficial effects for increase of time in range, with a notable reduction of time below range compared with those on isCGM. Real‐time CGM might provide better glycemic control than isCGM in children with type 1 diabetes. |
format | Online Article Text |
id | pubmed-9533045 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-95330452022-10-11 Comparison of the clinical effects of intermittently scanned and real‐time continuous glucose monitoring in children and adolescents with type 1 diabetes: A retrospective cohort study Urakami, Tatsuhiko Terada, Hiroki Yoshida, Kei Kuwabara, Remi Mine, Yusuke Aoki, Masako Shoji, Yasuko Suzuki, Junichi Morioka, Ichiro J Diabetes Investig Articles AIMS/INTRODUCTION: The aim of the study was to compare two continuous glucose monitoring (CGM) systems, intermittently scanned CGM (isCGM) and real‐time CGM (rtCGM), to determine which system achieved better glycemic control in pediatric patients. MATERIALS AND METHODS: We carried out a retrospective cohort study of children and adolescents with type 1 diabetes, and compared the time in range (70–180 mg/dL), time below range (<70 mg/dL) and time above range (>180 mg/dL), and estimated glycated hemoglobin levels between patients on isCGM and rtCGM. RESULTS: Of the 112 participants, 76 (67.9%) used isCGM and 36 (32.1%) used rtCGM for glycemic management. Patients on rtCGM had significantly greater time in range (57.7 ± 12.3% vs 52.3 ± 12.3%, P = 0.0368), and had significantly lower time below range (4.3 ± 2.7% vs 10.2% ± 5.4%, P < 0.001) than those on isCGM, but there was no significant difference in the time above range (37.4 ± 12.9% vs 38.0% ± 12.5%, P = 0.881) or the glycosylated hemoglobin A1c levels (7.4 ± 0.9% vs 7.5 ± 0.8%, P = 0.734) between the two groups. CONCLUSIONS: Pediatric patients with type 1 diabetes on rtCGM also showed more beneficial effects for increase of time in range, with a notable reduction of time below range compared with those on isCGM. Real‐time CGM might provide better glycemic control than isCGM in children with type 1 diabetes. John Wiley and Sons Inc. 2022-05-28 2022-10 /pmc/articles/PMC9533045/ /pubmed/35532954 http://dx.doi.org/10.1111/jdi.13830 Text en © 2022 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | Articles Urakami, Tatsuhiko Terada, Hiroki Yoshida, Kei Kuwabara, Remi Mine, Yusuke Aoki, Masako Shoji, Yasuko Suzuki, Junichi Morioka, Ichiro Comparison of the clinical effects of intermittently scanned and real‐time continuous glucose monitoring in children and adolescents with type 1 diabetes: A retrospective cohort study |
title | Comparison of the clinical effects of intermittently scanned and real‐time continuous glucose monitoring in children and adolescents with type 1 diabetes: A retrospective cohort study |
title_full | Comparison of the clinical effects of intermittently scanned and real‐time continuous glucose monitoring in children and adolescents with type 1 diabetes: A retrospective cohort study |
title_fullStr | Comparison of the clinical effects of intermittently scanned and real‐time continuous glucose monitoring in children and adolescents with type 1 diabetes: A retrospective cohort study |
title_full_unstemmed | Comparison of the clinical effects of intermittently scanned and real‐time continuous glucose monitoring in children and adolescents with type 1 diabetes: A retrospective cohort study |
title_short | Comparison of the clinical effects of intermittently scanned and real‐time continuous glucose monitoring in children and adolescents with type 1 diabetes: A retrospective cohort study |
title_sort | comparison of the clinical effects of intermittently scanned and real‐time continuous glucose monitoring in children and adolescents with type 1 diabetes: a retrospective cohort study |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9533045/ https://www.ncbi.nlm.nih.gov/pubmed/35532954 http://dx.doi.org/10.1111/jdi.13830 |
work_keys_str_mv | AT urakamitatsuhiko comparisonoftheclinicaleffectsofintermittentlyscannedandrealtimecontinuousglucosemonitoringinchildrenandadolescentswithtype1diabetesaretrospectivecohortstudy AT teradahiroki comparisonoftheclinicaleffectsofintermittentlyscannedandrealtimecontinuousglucosemonitoringinchildrenandadolescentswithtype1diabetesaretrospectivecohortstudy AT yoshidakei comparisonoftheclinicaleffectsofintermittentlyscannedandrealtimecontinuousglucosemonitoringinchildrenandadolescentswithtype1diabetesaretrospectivecohortstudy AT kuwabararemi comparisonoftheclinicaleffectsofintermittentlyscannedandrealtimecontinuousglucosemonitoringinchildrenandadolescentswithtype1diabetesaretrospectivecohortstudy AT mineyusuke comparisonoftheclinicaleffectsofintermittentlyscannedandrealtimecontinuousglucosemonitoringinchildrenandadolescentswithtype1diabetesaretrospectivecohortstudy AT aokimasako comparisonoftheclinicaleffectsofintermittentlyscannedandrealtimecontinuousglucosemonitoringinchildrenandadolescentswithtype1diabetesaretrospectivecohortstudy AT shojiyasuko comparisonoftheclinicaleffectsofintermittentlyscannedandrealtimecontinuousglucosemonitoringinchildrenandadolescentswithtype1diabetesaretrospectivecohortstudy AT suzukijunichi comparisonoftheclinicaleffectsofintermittentlyscannedandrealtimecontinuousglucosemonitoringinchildrenandadolescentswithtype1diabetesaretrospectivecohortstudy AT moriokaichiro comparisonoftheclinicaleffectsofintermittentlyscannedandrealtimecontinuousglucosemonitoringinchildrenandadolescentswithtype1diabetesaretrospectivecohortstudy |