Cargando…
Harmonization of dose prescription for lung stereotactic radiotherapy
BACKGROUND AND PURPOSE: Pulmonary stereotactic treatments can be performed using dedicated linear accelerators as well as robotic-assisted units, and different strategies can be used for dose prescription. This study aimed to compare the doses received by the tumor with a gross tumor volume (GTV)-ba...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9535417/ https://www.ncbi.nlm.nih.gov/pubmed/36213173 http://dx.doi.org/10.1016/j.phro.2022.09.007 |
_version_ | 1784802769295638528 |
---|---|
author | Beldjoudi, Guillaume Bosson, Fanny Bernard, Vivien Puel, Lise-Marie Martel-Lafay, Isabelle Ayadi, Myriam Tanguy, Ronan |
author_facet | Beldjoudi, Guillaume Bosson, Fanny Bernard, Vivien Puel, Lise-Marie Martel-Lafay, Isabelle Ayadi, Myriam Tanguy, Ronan |
author_sort | Beldjoudi, Guillaume |
collection | PubMed |
description | BACKGROUND AND PURPOSE: Pulmonary stereotactic treatments can be performed using dedicated linear accelerators as well as robotic-assisted units, and different strategies can be used for dose prescription. This study aimed to compare the doses received by the tumor with a gross tumor volume (GTV)-based prescription on D(98%GTV) using a robotic-assisted unit (method A) and planning target volume (PTV)-based prescription on D(95%PTV) using a dedicated linac (method B). MATERIAL & METHODS: Plans of 32 patients were collected for method A, and a dose of 3 × 18 Gy was prescribed using type A algorithm and recalculated using a Monte-Carlo (MC) algorithm. The plans were normalized to match D(98%GTV) with the mean [Formula: see text] of the cohort. The plans of 23 patients were collected for method B, and a dose of 3 × 18 Gy was prescribed to D(95%PTV) using a MC algorithm. A 4D-sum method was developed to estimate doses for PTV and GTV. For validation, all plans were recalculated using an independent MC double-check software. A dose harmonization on D(98% GTV) was determined for both methods. RESULTS: For method A, mean doses were D(2%GTV) = 59.9 ± 2.1 Gy, D(50%GTV) = 55.6 ± 1.2 Gy, D(98%GTV) = 49.5 ± 0.0 Gy. For method B, the reported doses were D(2%GTV) = 64.6 ± 2.1 Gy, D(50%GTV) = 62.8 ± 1.7 Gy, and D(98%GTV) = 60.0 ± 1.7 Gy. The dose trade-off of D(98%GTV) = 55 Gy was obtained for both methods. For method A, it corresponded to a dose prescription of 3 × 20 Gy using type A algorithm, followed by rescaling to obtain D(98%GTV) = 55 Gy. For method B, it corresponded to a dose prescription of D(95%PTV) = 3 × 16.5 Gy using the MC algorithm. CONCLUSIONS: This study determined similar near-minimum doses D(98% GTV) of approximately 3 × 18.3 Gy (55 Gy) using a GTV-based prescription on a robotic-assisted unit (method A) and a PTV-based prescription on a dedicated linac (method B). |
format | Online Article Text |
id | pubmed-9535417 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-95354172022-10-07 Harmonization of dose prescription for lung stereotactic radiotherapy Beldjoudi, Guillaume Bosson, Fanny Bernard, Vivien Puel, Lise-Marie Martel-Lafay, Isabelle Ayadi, Myriam Tanguy, Ronan Phys Imaging Radiat Oncol Original Research Article BACKGROUND AND PURPOSE: Pulmonary stereotactic treatments can be performed using dedicated linear accelerators as well as robotic-assisted units, and different strategies can be used for dose prescription. This study aimed to compare the doses received by the tumor with a gross tumor volume (GTV)-based prescription on D(98%GTV) using a robotic-assisted unit (method A) and planning target volume (PTV)-based prescription on D(95%PTV) using a dedicated linac (method B). MATERIAL & METHODS: Plans of 32 patients were collected for method A, and a dose of 3 × 18 Gy was prescribed using type A algorithm and recalculated using a Monte-Carlo (MC) algorithm. The plans were normalized to match D(98%GTV) with the mean [Formula: see text] of the cohort. The plans of 23 patients were collected for method B, and a dose of 3 × 18 Gy was prescribed to D(95%PTV) using a MC algorithm. A 4D-sum method was developed to estimate doses for PTV and GTV. For validation, all plans were recalculated using an independent MC double-check software. A dose harmonization on D(98% GTV) was determined for both methods. RESULTS: For method A, mean doses were D(2%GTV) = 59.9 ± 2.1 Gy, D(50%GTV) = 55.6 ± 1.2 Gy, D(98%GTV) = 49.5 ± 0.0 Gy. For method B, the reported doses were D(2%GTV) = 64.6 ± 2.1 Gy, D(50%GTV) = 62.8 ± 1.7 Gy, and D(98%GTV) = 60.0 ± 1.7 Gy. The dose trade-off of D(98%GTV) = 55 Gy was obtained for both methods. For method A, it corresponded to a dose prescription of 3 × 20 Gy using type A algorithm, followed by rescaling to obtain D(98%GTV) = 55 Gy. For method B, it corresponded to a dose prescription of D(95%PTV) = 3 × 16.5 Gy using the MC algorithm. CONCLUSIONS: This study determined similar near-minimum doses D(98% GTV) of approximately 3 × 18.3 Gy (55 Gy) using a GTV-based prescription on a robotic-assisted unit (method A) and a PTV-based prescription on a dedicated linac (method B). Elsevier 2022-09-29 /pmc/articles/PMC9535417/ /pubmed/36213173 http://dx.doi.org/10.1016/j.phro.2022.09.007 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Research Article Beldjoudi, Guillaume Bosson, Fanny Bernard, Vivien Puel, Lise-Marie Martel-Lafay, Isabelle Ayadi, Myriam Tanguy, Ronan Harmonization of dose prescription for lung stereotactic radiotherapy |
title | Harmonization of dose prescription for lung stereotactic radiotherapy |
title_full | Harmonization of dose prescription for lung stereotactic radiotherapy |
title_fullStr | Harmonization of dose prescription for lung stereotactic radiotherapy |
title_full_unstemmed | Harmonization of dose prescription for lung stereotactic radiotherapy |
title_short | Harmonization of dose prescription for lung stereotactic radiotherapy |
title_sort | harmonization of dose prescription for lung stereotactic radiotherapy |
topic | Original Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9535417/ https://www.ncbi.nlm.nih.gov/pubmed/36213173 http://dx.doi.org/10.1016/j.phro.2022.09.007 |
work_keys_str_mv | AT beldjoudiguillaume harmonizationofdoseprescriptionforlungstereotacticradiotherapy AT bossonfanny harmonizationofdoseprescriptionforlungstereotacticradiotherapy AT bernardvivien harmonizationofdoseprescriptionforlungstereotacticradiotherapy AT puellisemarie harmonizationofdoseprescriptionforlungstereotacticradiotherapy AT martellafayisabelle harmonizationofdoseprescriptionforlungstereotacticradiotherapy AT ayadimyriam harmonizationofdoseprescriptionforlungstereotacticradiotherapy AT tanguyronan harmonizationofdoseprescriptionforlungstereotacticradiotherapy |