Cargando…

Placement of catheters without magnetic sensors in the coronary sinus without fluoroscopic guidance: Feasibility and safety evaluation

BACKGROUND: A three‐dimensional (3D) mapping system is essential to reduce radiation exposure during catheter ablation. When using the CARTO 3D mapping system, only the catheter with magnetic sensor can visualize its location. However, once target chamber matrix is created using the catheter, even t...

Descripción completa

Detalles Bibliográficos
Autores principales: Hoshiyama, Tadashi, Sumi, Hitoshi, Kaneko, Shozo, Kawahara, Yusei, Ito, Miwa, Kanazawa, Hisanori, Takashio, Seiji, Yamamoto, Eiichiro, Matsushita, Kenichi, Tsujita, Kenichi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9535797/
https://www.ncbi.nlm.nih.gov/pubmed/36237862
http://dx.doi.org/10.1002/joa3.12763
_version_ 1784802849495973888
author Hoshiyama, Tadashi
Sumi, Hitoshi
Kaneko, Shozo
Kawahara, Yusei
Ito, Miwa
Kanazawa, Hisanori
Takashio, Seiji
Yamamoto, Eiichiro
Matsushita, Kenichi
Tsujita, Kenichi
author_facet Hoshiyama, Tadashi
Sumi, Hitoshi
Kaneko, Shozo
Kawahara, Yusei
Ito, Miwa
Kanazawa, Hisanori
Takashio, Seiji
Yamamoto, Eiichiro
Matsushita, Kenichi
Tsujita, Kenichi
author_sort Hoshiyama, Tadashi
collection PubMed
description BACKGROUND: A three‐dimensional (3D) mapping system is essential to reduce radiation exposure during catheter ablation. When using the CARTO 3D mapping system, only the catheter with magnetic sensor can visualize its location. However, once target chamber matrix is created using the catheter, even the catheters without magnetic sensors (CWMS) can enable visualization. We aimed to investigate the feasibility and safety of placing a CWMS in the coronary sinus (CS) without fluoroscopic guidance. METHODS: The study group comprised 88 consecutive patients who underwent catheter ablation. CWMS placement was performed without fluoroscopic guidance in 47 patients and with fluoroscopic guidance in 41 patients. Placement without fluoroscopic guidance was performed after creating a visualization matrix of the CS, right atrium, and superior vena cava using a catheter with a magnetic sensor. Feasibility and safety were compared between the two groups. RESULTS: Successful catheter placement was achieved in all patients without fluoroscopic guidance, with no inter‐group difference in the median procedure time: with guidance, 120.0 [96.0–135.0] min, and without guidance, 110.0 [97.5–125.0] min; p = .22. However, radiation exposure was significantly shorter, and the effective dose was lower without fluoroscopic guidance (0 [0–17.5] s and 0 [0–0.004] mSv, respectively) than with fluoroscopic guidance (420.0 [270.0–644.0] s and 0.73 mSv [0.36–1.26], respectively); both p < .001. CONCLUSIONS: CWMS placement without fluoroscopic guidance is feasible, safe to perform, and does not involve complications. Our technique provides an option to decrease radiation exposure during catheter ablation and electrophysiological testing.
format Online
Article
Text
id pubmed-9535797
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-95357972022-10-12 Placement of catheters without magnetic sensors in the coronary sinus without fluoroscopic guidance: Feasibility and safety evaluation Hoshiyama, Tadashi Sumi, Hitoshi Kaneko, Shozo Kawahara, Yusei Ito, Miwa Kanazawa, Hisanori Takashio, Seiji Yamamoto, Eiichiro Matsushita, Kenichi Tsujita, Kenichi J Arrhythm Original Articles BACKGROUND: A three‐dimensional (3D) mapping system is essential to reduce radiation exposure during catheter ablation. When using the CARTO 3D mapping system, only the catheter with magnetic sensor can visualize its location. However, once target chamber matrix is created using the catheter, even the catheters without magnetic sensors (CWMS) can enable visualization. We aimed to investigate the feasibility and safety of placing a CWMS in the coronary sinus (CS) without fluoroscopic guidance. METHODS: The study group comprised 88 consecutive patients who underwent catheter ablation. CWMS placement was performed without fluoroscopic guidance in 47 patients and with fluoroscopic guidance in 41 patients. Placement without fluoroscopic guidance was performed after creating a visualization matrix of the CS, right atrium, and superior vena cava using a catheter with a magnetic sensor. Feasibility and safety were compared between the two groups. RESULTS: Successful catheter placement was achieved in all patients without fluoroscopic guidance, with no inter‐group difference in the median procedure time: with guidance, 120.0 [96.0–135.0] min, and without guidance, 110.0 [97.5–125.0] min; p = .22. However, radiation exposure was significantly shorter, and the effective dose was lower without fluoroscopic guidance (0 [0–17.5] s and 0 [0–0.004] mSv, respectively) than with fluoroscopic guidance (420.0 [270.0–644.0] s and 0.73 mSv [0.36–1.26], respectively); both p < .001. CONCLUSIONS: CWMS placement without fluoroscopic guidance is feasible, safe to perform, and does not involve complications. Our technique provides an option to decrease radiation exposure during catheter ablation and electrophysiological testing. John Wiley and Sons Inc. 2022-08-05 /pmc/articles/PMC9535797/ /pubmed/36237862 http://dx.doi.org/10.1002/joa3.12763 Text en © 2022 The Authors. Journal of Arrhythmia published by John Wiley & Sons Australia, Ltd on behalf of Japanese Heart Rhythm Society. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Articles
Hoshiyama, Tadashi
Sumi, Hitoshi
Kaneko, Shozo
Kawahara, Yusei
Ito, Miwa
Kanazawa, Hisanori
Takashio, Seiji
Yamamoto, Eiichiro
Matsushita, Kenichi
Tsujita, Kenichi
Placement of catheters without magnetic sensors in the coronary sinus without fluoroscopic guidance: Feasibility and safety evaluation
title Placement of catheters without magnetic sensors in the coronary sinus without fluoroscopic guidance: Feasibility and safety evaluation
title_full Placement of catheters without magnetic sensors in the coronary sinus without fluoroscopic guidance: Feasibility and safety evaluation
title_fullStr Placement of catheters without magnetic sensors in the coronary sinus without fluoroscopic guidance: Feasibility and safety evaluation
title_full_unstemmed Placement of catheters without magnetic sensors in the coronary sinus without fluoroscopic guidance: Feasibility and safety evaluation
title_short Placement of catheters without magnetic sensors in the coronary sinus without fluoroscopic guidance: Feasibility and safety evaluation
title_sort placement of catheters without magnetic sensors in the coronary sinus without fluoroscopic guidance: feasibility and safety evaluation
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9535797/
https://www.ncbi.nlm.nih.gov/pubmed/36237862
http://dx.doi.org/10.1002/joa3.12763
work_keys_str_mv AT hoshiyamatadashi placementofcatheterswithoutmagneticsensorsinthecoronarysinuswithoutfluoroscopicguidancefeasibilityandsafetyevaluation
AT sumihitoshi placementofcatheterswithoutmagneticsensorsinthecoronarysinuswithoutfluoroscopicguidancefeasibilityandsafetyevaluation
AT kanekoshozo placementofcatheterswithoutmagneticsensorsinthecoronarysinuswithoutfluoroscopicguidancefeasibilityandsafetyevaluation
AT kawaharayusei placementofcatheterswithoutmagneticsensorsinthecoronarysinuswithoutfluoroscopicguidancefeasibilityandsafetyevaluation
AT itomiwa placementofcatheterswithoutmagneticsensorsinthecoronarysinuswithoutfluoroscopicguidancefeasibilityandsafetyevaluation
AT kanazawahisanori placementofcatheterswithoutmagneticsensorsinthecoronarysinuswithoutfluoroscopicguidancefeasibilityandsafetyevaluation
AT takashioseiji placementofcatheterswithoutmagneticsensorsinthecoronarysinuswithoutfluoroscopicguidancefeasibilityandsafetyevaluation
AT yamamotoeiichiro placementofcatheterswithoutmagneticsensorsinthecoronarysinuswithoutfluoroscopicguidancefeasibilityandsafetyevaluation
AT matsushitakenichi placementofcatheterswithoutmagneticsensorsinthecoronarysinuswithoutfluoroscopicguidancefeasibilityandsafetyevaluation
AT tsujitakenichi placementofcatheterswithoutmagneticsensorsinthecoronarysinuswithoutfluoroscopicguidancefeasibilityandsafetyevaluation