Cargando…
Evaluation of Data-Driven Rigid Motion Correction in Clinical Brain PET Imaging
Head motion during brain PET imaging can significantly degrade the quality of the reconstructed image, leading to reduced diagnostic value and inaccurate quantitation. A fully data-driven motion correction approach was recently demonstrated to produce highly accurate motion estimates (<1 mm) with...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Society of Nuclear Medicine
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9536704/ https://www.ncbi.nlm.nih.gov/pubmed/35086896 http://dx.doi.org/10.2967/jnumed.121.263309 |
_version_ | 1784803038890819584 |
---|---|
author | Spangler-Bickell, Matthew G. Hurley, Samuel A. Pirasteh, Ali Perlman, Scott B. Deller, Timothy McMillan, Alan B. |
author_facet | Spangler-Bickell, Matthew G. Hurley, Samuel A. Pirasteh, Ali Perlman, Scott B. Deller, Timothy McMillan, Alan B. |
author_sort | Spangler-Bickell, Matthew G. |
collection | PubMed |
description | Head motion during brain PET imaging can significantly degrade the quality of the reconstructed image, leading to reduced diagnostic value and inaccurate quantitation. A fully data-driven motion correction approach was recently demonstrated to produce highly accurate motion estimates (<1 mm) with high temporal resolution (≥1 Hz), which can then be used for a motion-corrected reconstruction. This can be applied retrospectively with no impact on the clinical image acquisition protocol. We present a reader-based evaluation and an atlas-based quantitative analysis of this motion correction approach within a clinical cohort. Methods: Clinical patient data were collected over 2019–2020 and processed retrospectively. Motion was estimated using image-based registration on reconstructions of ultrashort frames (0.6–1.8 s), after which list-mode reconstructions that were fully motion-corrected were performed. Two readers graded the motion-corrected and uncorrected reconstructions. An atlas-based quantitative analysis was performed. Paired Wilcoxon tests were used to test for significant differences in reader scores and SUVs between reconstructions. The Levene test was used to determine whether motion correction had a greater impact on quantitation in the presence of motion than when motion was low. Results: Fifty standard clinical (18)F-FDG brain PET datasets (age range, 13–83 y; mean ± SD, 59 ± 20 y; 27 women) from 3 scanners were collected. The reader study showed a significantly different, diagnostically relevant improvement by motion correction when motion was present (P = 0.02) and no impact in low-motion cases. Eight percent of all datasets improved from diagnostically unacceptable to acceptable. The atlas-based analysis demonstrated a significant difference between the motion-corrected and uncorrected reconstructions in cases of high motion for 7 of 8 regions of interest (P < 0.05). Conclusion: The proposed approach to data-driven motion estimation and correction demonstrated a clinically significant impact on brain PET image reconstruction. |
format | Online Article Text |
id | pubmed-9536704 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Society of Nuclear Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-95367042023-04-01 Evaluation of Data-Driven Rigid Motion Correction in Clinical Brain PET Imaging Spangler-Bickell, Matthew G. Hurley, Samuel A. Pirasteh, Ali Perlman, Scott B. Deller, Timothy McMillan, Alan B. J Nucl Med Basic Science Investigation Head motion during brain PET imaging can significantly degrade the quality of the reconstructed image, leading to reduced diagnostic value and inaccurate quantitation. A fully data-driven motion correction approach was recently demonstrated to produce highly accurate motion estimates (<1 mm) with high temporal resolution (≥1 Hz), which can then be used for a motion-corrected reconstruction. This can be applied retrospectively with no impact on the clinical image acquisition protocol. We present a reader-based evaluation and an atlas-based quantitative analysis of this motion correction approach within a clinical cohort. Methods: Clinical patient data were collected over 2019–2020 and processed retrospectively. Motion was estimated using image-based registration on reconstructions of ultrashort frames (0.6–1.8 s), after which list-mode reconstructions that were fully motion-corrected were performed. Two readers graded the motion-corrected and uncorrected reconstructions. An atlas-based quantitative analysis was performed. Paired Wilcoxon tests were used to test for significant differences in reader scores and SUVs between reconstructions. The Levene test was used to determine whether motion correction had a greater impact on quantitation in the presence of motion than when motion was low. Results: Fifty standard clinical (18)F-FDG brain PET datasets (age range, 13–83 y; mean ± SD, 59 ± 20 y; 27 women) from 3 scanners were collected. The reader study showed a significantly different, diagnostically relevant improvement by motion correction when motion was present (P = 0.02) and no impact in low-motion cases. Eight percent of all datasets improved from diagnostically unacceptable to acceptable. The atlas-based analysis demonstrated a significant difference between the motion-corrected and uncorrected reconstructions in cases of high motion for 7 of 8 regions of interest (P < 0.05). Conclusion: The proposed approach to data-driven motion estimation and correction demonstrated a clinically significant impact on brain PET image reconstruction. Society of Nuclear Medicine 2022-10 /pmc/articles/PMC9536704/ /pubmed/35086896 http://dx.doi.org/10.2967/jnumed.121.263309 Text en © 2022 by the Society of Nuclear Medicine and Molecular Imaging. https://creativecommons.org/licenses/by/4.0/Immediate Open Access: Creative Commons Attribution 4.0 International License (CC BY) allows users to share and adapt with attribution, excluding materials credited to previous publications. License: https://creativecommons.org/licenses/by/4.0/. Details: http://jnm.snmjournals.org/site/misc/permission.xhtml. |
spellingShingle | Basic Science Investigation Spangler-Bickell, Matthew G. Hurley, Samuel A. Pirasteh, Ali Perlman, Scott B. Deller, Timothy McMillan, Alan B. Evaluation of Data-Driven Rigid Motion Correction in Clinical Brain PET Imaging |
title | Evaluation of Data-Driven Rigid Motion Correction in Clinical Brain PET Imaging |
title_full | Evaluation of Data-Driven Rigid Motion Correction in Clinical Brain PET Imaging |
title_fullStr | Evaluation of Data-Driven Rigid Motion Correction in Clinical Brain PET Imaging |
title_full_unstemmed | Evaluation of Data-Driven Rigid Motion Correction in Clinical Brain PET Imaging |
title_short | Evaluation of Data-Driven Rigid Motion Correction in Clinical Brain PET Imaging |
title_sort | evaluation of data-driven rigid motion correction in clinical brain pet imaging |
topic | Basic Science Investigation |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9536704/ https://www.ncbi.nlm.nih.gov/pubmed/35086896 http://dx.doi.org/10.2967/jnumed.121.263309 |
work_keys_str_mv | AT spanglerbickellmatthewg evaluationofdatadrivenrigidmotioncorrectioninclinicalbrainpetimaging AT hurleysamuela evaluationofdatadrivenrigidmotioncorrectioninclinicalbrainpetimaging AT pirastehali evaluationofdatadrivenrigidmotioncorrectioninclinicalbrainpetimaging AT perlmanscottb evaluationofdatadrivenrigidmotioncorrectioninclinicalbrainpetimaging AT dellertimothy evaluationofdatadrivenrigidmotioncorrectioninclinicalbrainpetimaging AT mcmillanalanb evaluationofdatadrivenrigidmotioncorrectioninclinicalbrainpetimaging |