Cargando…

Thirty second chair stand test: Test–retest reliability, agreement and minimum detectable change in people with early‐stage knee osteoarthritis

BACKGROUND AND PURPOSE: To determine intra‐session test‐retest reliability, agreement and minimum detectable change (MDC) of the 30 CST across three tests in people with knee osteoarthritis (OA). METHODS: A test–retest reliability study was performed with 93 people with mild radiological knee OA. Pa...

Descripción completa

Detalles Bibliográficos
Autores principales: Gill, Stephen, Hely, Rachael, Page, Richard S., Hely, Andrew, Harrison, Benjamin, Landers, Steve
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9539496/
https://www.ncbi.nlm.nih.gov/pubmed/35592902
http://dx.doi.org/10.1002/pri.1957
_version_ 1784803501098926080
author Gill, Stephen
Hely, Rachael
Page, Richard S.
Hely, Andrew
Harrison, Benjamin
Landers, Steve
author_facet Gill, Stephen
Hely, Rachael
Page, Richard S.
Hely, Andrew
Harrison, Benjamin
Landers, Steve
author_sort Gill, Stephen
collection PubMed
description BACKGROUND AND PURPOSE: To determine intra‐session test‐retest reliability, agreement and minimum detectable change (MDC) of the 30 CST across three tests in people with knee osteoarthritis (OA). METHODS: A test–retest reliability study was performed with 93 people with mild radiological knee OA. Participants were asked to complete three attempts of the 30 CST 1–2 min apart according to a standardised protocol. Participants completed three attempts on two occasions: baseline and 6 months later. Change between tests within each session was assessed with ANOVA's and post‐hoc t‐tests. Reliability was assessed with intra‐class correlation coefficients (ICC([2,1])). Measurement error was expressed as MDC for an individual (MDC(ind)) and a group (MDC(group)). Floor effects were considered present if more than 15% of participants scored zero for a test. RESULTS: Scores increased by 0.5 and 0.8 stands between the first and second test (p < 0.05) at the baseline and 6‐month assessments respectively, and then stabilised between the second the third tests at the baseline assessment (p > 0.05) or decreased (0.3 stands) at the 6‐month assessment (p < 0.05). Scores demonstrated excellent reliability (ICCs >0.9). MDC(ind) was approximately 2.5 stands and MDC(group) was 0.3–0.4 stands. No floor effects were apparent. DISCUSSION: The 30CST demonstrated a practice effect between the first and second tests, which was no longer apparent by the third test. Despite this, scores demonstrated excellent intra‐session reliability. MDC estimates provide clinicians and researchers with the smallest change that can be detected by the instrument beyond measurement error for individuals and groups in community‐dwelling adults with knee OA.
format Online
Article
Text
id pubmed-9539496
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-95394962022-10-14 Thirty second chair stand test: Test–retest reliability, agreement and minimum detectable change in people with early‐stage knee osteoarthritis Gill, Stephen Hely, Rachael Page, Richard S. Hely, Andrew Harrison, Benjamin Landers, Steve Physiother Res Int Research Articles BACKGROUND AND PURPOSE: To determine intra‐session test‐retest reliability, agreement and minimum detectable change (MDC) of the 30 CST across three tests in people with knee osteoarthritis (OA). METHODS: A test–retest reliability study was performed with 93 people with mild radiological knee OA. Participants were asked to complete three attempts of the 30 CST 1–2 min apart according to a standardised protocol. Participants completed three attempts on two occasions: baseline and 6 months later. Change between tests within each session was assessed with ANOVA's and post‐hoc t‐tests. Reliability was assessed with intra‐class correlation coefficients (ICC([2,1])). Measurement error was expressed as MDC for an individual (MDC(ind)) and a group (MDC(group)). Floor effects were considered present if more than 15% of participants scored zero for a test. RESULTS: Scores increased by 0.5 and 0.8 stands between the first and second test (p < 0.05) at the baseline and 6‐month assessments respectively, and then stabilised between the second the third tests at the baseline assessment (p > 0.05) or decreased (0.3 stands) at the 6‐month assessment (p < 0.05). Scores demonstrated excellent reliability (ICCs >0.9). MDC(ind) was approximately 2.5 stands and MDC(group) was 0.3–0.4 stands. No floor effects were apparent. DISCUSSION: The 30CST demonstrated a practice effect between the first and second tests, which was no longer apparent by the third test. Despite this, scores demonstrated excellent intra‐session reliability. MDC estimates provide clinicians and researchers with the smallest change that can be detected by the instrument beyond measurement error for individuals and groups in community‐dwelling adults with knee OA. John Wiley and Sons Inc. 2022-05-19 2022-07 /pmc/articles/PMC9539496/ /pubmed/35592902 http://dx.doi.org/10.1002/pri.1957 Text en © 2022 The Authors. Physiotherapy Research International published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Gill, Stephen
Hely, Rachael
Page, Richard S.
Hely, Andrew
Harrison, Benjamin
Landers, Steve
Thirty second chair stand test: Test–retest reliability, agreement and minimum detectable change in people with early‐stage knee osteoarthritis
title Thirty second chair stand test: Test–retest reliability, agreement and minimum detectable change in people with early‐stage knee osteoarthritis
title_full Thirty second chair stand test: Test–retest reliability, agreement and minimum detectable change in people with early‐stage knee osteoarthritis
title_fullStr Thirty second chair stand test: Test–retest reliability, agreement and minimum detectable change in people with early‐stage knee osteoarthritis
title_full_unstemmed Thirty second chair stand test: Test–retest reliability, agreement and minimum detectable change in people with early‐stage knee osteoarthritis
title_short Thirty second chair stand test: Test–retest reliability, agreement and minimum detectable change in people with early‐stage knee osteoarthritis
title_sort thirty second chair stand test: test–retest reliability, agreement and minimum detectable change in people with early‐stage knee osteoarthritis
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9539496/
https://www.ncbi.nlm.nih.gov/pubmed/35592902
http://dx.doi.org/10.1002/pri.1957
work_keys_str_mv AT gillstephen thirtysecondchairstandtesttestretestreliabilityagreementandminimumdetectablechangeinpeoplewithearlystagekneeosteoarthritis
AT helyrachael thirtysecondchairstandtesttestretestreliabilityagreementandminimumdetectablechangeinpeoplewithearlystagekneeosteoarthritis
AT pagerichards thirtysecondchairstandtesttestretestreliabilityagreementandminimumdetectablechangeinpeoplewithearlystagekneeosteoarthritis
AT helyandrew thirtysecondchairstandtesttestretestreliabilityagreementandminimumdetectablechangeinpeoplewithearlystagekneeosteoarthritis
AT harrisonbenjamin thirtysecondchairstandtesttestretestreliabilityagreementandminimumdetectablechangeinpeoplewithearlystagekneeosteoarthritis
AT landerssteve thirtysecondchairstandtesttestretestreliabilityagreementandminimumdetectablechangeinpeoplewithearlystagekneeosteoarthritis