Cargando…

Validation of the X-ray microtomography in the assessment of duodenal morphometry and surface area in celiac disease

BACKGROUND: Duodenal histology remains the diagnostic reference standard in celiac disease. However, traditional methods have suboptimal sensitivity and reproducibility for early mucosal changes and research purposes. We validated a recently introduced micro-CT imaging method for an accurate digital...

Descripción completa

Detalles Bibliográficos
Autores principales: Virta, Johannes, Hannula, Markus, Lindfors, Katri, Tamminen, Ilmari, Taavela, Juha, Huhtala, Heini, Kaukinen, Katri, Saavalainen, Päivi, Hyttinen, Jari, Kurppa, Kalle
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9539806/
https://www.ncbi.nlm.nih.gov/pubmed/36211435
http://dx.doi.org/10.3389/fimmu.2022.945197
Descripción
Sumario:BACKGROUND: Duodenal histology remains the diagnostic reference standard in celiac disease. However, traditional methods have suboptimal sensitivity and reproducibility for early mucosal changes and research purposes. We validated a recently introduced micro-CT imaging method for an accurate digital evaluation of duodenal histomorphometry and mucosal surface areas. METHODS: Endoscopic biopsies from 58 individuals were utilized for the micro-CT imaging, selecting histological changes ranging from normal to severely damaged mucosa. The imaging protocol was optimized for practicability and resolution. The Bland–Altman method was applied to test intra- and interobserver variations in the blinded measurements. RESULTS: The 3D micro-CT reconstructions enabled easy and precise digital cutting with optimal orientation and computer-assisted measurement of the surface area. Intraobserver analysis of morphological measurements showed a mean difference of 0.011 with limits of agreement (LA) from -0.397 to 0.375 and a standard deviation (SD) of 0.197. The corresponding figures for interobserver analysis were 0.080, from -0.719 to 0.537 and 0.320, respectively. The intraclass correlation coefficients (ICC) for the intraobserver and interobserver variations were 0.981 and 0.954, respectively. Intraobserver surface area analysis yielded a mean difference of 0.010, LA from -0.764 to 0.785 and an SD of 0.395, and an interobserver analysis mean difference of 0.028, LA from -0.642 to 0.698 and SD of 0.342. The respective ICCs for the intra- and interobserver variations were 0.963 and 0.972. CONCLUSIONS: Micro-CT showed excellent accuracy and reproducibility in the evaluation of mucosal morphometry and surface areas. The improved sensitivity for histological changes is a powerful tool for the diagnosis of celiac disease and for clinical and pharmacological studies.