Cargando…

A novel bone suppression algorithm in intensity‐based 2D/3D image registration for real‐time tumor motion monitoring: Development and phantom‐based validation

BACKGROUND: Real‐time tumor motion monitoring (TMM) is a crucial process for intra‐fractional respiration management in lung cancer radiotherapy. Since the tumor can be partly or fully located behind the ribs, the TMM is challenging. PURPOSE: The aim of this work was to develop a bone suppression (B...

Descripción completa

Detalles Bibliográficos
Autores principales: Gulyas, Ingo, Trnkova, Petra, Knäusl, Barbara, Widder, Joachim, Georg, Dietmar, Renner, Andreas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9540269/
https://www.ncbi.nlm.nih.gov/pubmed/35598307
http://dx.doi.org/10.1002/mp.15716
Descripción
Sumario:BACKGROUND: Real‐time tumor motion monitoring (TMM) is a crucial process for intra‐fractional respiration management in lung cancer radiotherapy. Since the tumor can be partly or fully located behind the ribs, the TMM is challenging. PURPOSE: The aim of this work was to develop a bone suppression (BS) algorithm designed for real‐time 2D/3D marker‐less TMM to increase the visibility of the tumor when overlapping with bony structures and consequently to improve the accuracy of TMM. METHOD: A BS method was implemented in the in‐house developed software for ultrafast intensity‐based 2D/3D tumor registration (Fast Image‐based Registration [FIRE]). The method operates on both, digitally reconstructed radiograph (DRR) and intra‐fractional X‐ray images. The bony structures are derived from computed tomography data by thresholding during ray‐casting, and the resulting bone DRR is subtracted from intra‐fractional X‐ray images to obtain a soft‐tissue‐only image for subsequent tumor registration. The accuracy of TMM utilizing BS was evaluated within a retrospective phantom study with nine different 3D‐printed tumor phantoms placed in the in‐house developed Advanced Radiation DOSimetry (ARDOS) breathing phantom. A 24 mm craniocaudal tumor motion, including rib eclipses, was simulated, and X‐ray images were acquired on the Elekta Versa HD Linac in the lateral and posterior–anterior directions. An error assessment for BS images was evaluated with respect to the ground truth tumor position. RESULTS: A total error (root mean square error) of 0.87 ± 0.23 mm and 1.03 ± 0.26 mm was found for posterior–anterior and lateral imaging; the mean time for BS was 8.03 ± 1.54 ms. Without utilizing BS, TMM failed in all X‐ray images since the registration algorithm focused on the rib position due to the predominant intensity of this tissue within DRR and X‐ray images. CONCLUSION: The BS algorithm developed and implemented improved the accuracy, robustness, and stability of real‐time TMM in lung cancer in a phantom study, even in the case of rib interlude where normal tumor registration fails.