Cargando…

A rapid high‐precision analytical method for triple oxygen isotope analysis of CO(2) gas using tunable infrared laser direct absorption spectroscopy

RATIONALE: The simultaneous analysis of the three stable isotopes of oxygen—triple oxygen isotope analysis—has become an important analytical technique in natural sciences. Determination of the abundance of the rare (17)O isotope in CO(2) gas using magnetic sector isotope ratio mass spectrometry is...

Descripción completa

Detalles Bibliográficos
Autores principales: Perdue, Nathan, Sharp, Zachary, Nelson, David, Wehr, Rick, Dyroff, Christoph
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9541814/
https://www.ncbi.nlm.nih.gov/pubmed/36056818
http://dx.doi.org/10.1002/rcm.9391
_version_ 1784804008008876032
author Perdue, Nathan
Sharp, Zachary
Nelson, David
Wehr, Rick
Dyroff, Christoph
author_facet Perdue, Nathan
Sharp, Zachary
Nelson, David
Wehr, Rick
Dyroff, Christoph
author_sort Perdue, Nathan
collection PubMed
description RATIONALE: The simultaneous analysis of the three stable isotopes of oxygen—triple oxygen isotope analysis—has become an important analytical technique in natural sciences. Determination of the abundance of the rare (17)O isotope in CO(2) gas using magnetic sector isotope ratio mass spectrometry is complicated by the isobaric interference of (17)O by (13)C ((13)C(16)O(16)O and (12)C(16)O(17)O, both have mass 45 amu). A number of analytical techniques have been used to measure the (17)O/(16)O ratio of CO(2) gas. They either are time consuming and technically challenging or have limited precision. A rapid and precise alternative to the available analytical methods is desirable. METHODS: We present the results of triple oxygen isotope analyses using an Aerodyne tunable infrared laser direct absorption spectroscopy (TILDAS) CO(2) analyzer configured for (16)O, (17)O, and (18)O combined with a custom gas inlet system. We evaluate the sensitivity of our results to a number of parameters. CO(2) samples with a wide range of δ(18)O values (from −9.28‰ to 39.56‰) were measured and compared to results using the well‐established fluorination‐gas source mass spectrometry method. RESULTS: The TILDAS system has a precision (standard error, 2σ) of better than ±0.03‰ for δ(18)O and ±10 per meg for Δ′(17)O values, equivalent to the precision of previous analytical methods. Samples as small as 3 μmol CO(2) (equivalent to 300 μg CaCO(3)) can be analyzed with a total analysis time of ~30 min. CONCLUSIONS: We have successfully developed an analytical technique for the simultaneous determination of the δ(17)O and δ(18)O values of CO(2) gas. The precision is equal to or better than that of existing techniques, with no additional chemical treatments required. Analysis time is rapid, and the system is easily automated so that large numbers of samples can be analyzed with minimal effort.
format Online
Article
Text
id pubmed-9541814
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-95418142022-10-14 A rapid high‐precision analytical method for triple oxygen isotope analysis of CO(2) gas using tunable infrared laser direct absorption spectroscopy Perdue, Nathan Sharp, Zachary Nelson, David Wehr, Rick Dyroff, Christoph Rapid Commun Mass Spectrom Research Articles RATIONALE: The simultaneous analysis of the three stable isotopes of oxygen—triple oxygen isotope analysis—has become an important analytical technique in natural sciences. Determination of the abundance of the rare (17)O isotope in CO(2) gas using magnetic sector isotope ratio mass spectrometry is complicated by the isobaric interference of (17)O by (13)C ((13)C(16)O(16)O and (12)C(16)O(17)O, both have mass 45 amu). A number of analytical techniques have been used to measure the (17)O/(16)O ratio of CO(2) gas. They either are time consuming and technically challenging or have limited precision. A rapid and precise alternative to the available analytical methods is desirable. METHODS: We present the results of triple oxygen isotope analyses using an Aerodyne tunable infrared laser direct absorption spectroscopy (TILDAS) CO(2) analyzer configured for (16)O, (17)O, and (18)O combined with a custom gas inlet system. We evaluate the sensitivity of our results to a number of parameters. CO(2) samples with a wide range of δ(18)O values (from −9.28‰ to 39.56‰) were measured and compared to results using the well‐established fluorination‐gas source mass spectrometry method. RESULTS: The TILDAS system has a precision (standard error, 2σ) of better than ±0.03‰ for δ(18)O and ±10 per meg for Δ′(17)O values, equivalent to the precision of previous analytical methods. Samples as small as 3 μmol CO(2) (equivalent to 300 μg CaCO(3)) can be analyzed with a total analysis time of ~30 min. CONCLUSIONS: We have successfully developed an analytical technique for the simultaneous determination of the δ(17)O and δ(18)O values of CO(2) gas. The precision is equal to or better than that of existing techniques, with no additional chemical treatments required. Analysis time is rapid, and the system is easily automated so that large numbers of samples can be analyzed with minimal effort. John Wiley and Sons Inc. 2022-09-16 2022-11-15 /pmc/articles/PMC9541814/ /pubmed/36056818 http://dx.doi.org/10.1002/rcm.9391 Text en © 2022 The Authors. Rapid Communications in Mass Spectrometry published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Research Articles
Perdue, Nathan
Sharp, Zachary
Nelson, David
Wehr, Rick
Dyroff, Christoph
A rapid high‐precision analytical method for triple oxygen isotope analysis of CO(2) gas using tunable infrared laser direct absorption spectroscopy
title A rapid high‐precision analytical method for triple oxygen isotope analysis of CO(2) gas using tunable infrared laser direct absorption spectroscopy
title_full A rapid high‐precision analytical method for triple oxygen isotope analysis of CO(2) gas using tunable infrared laser direct absorption spectroscopy
title_fullStr A rapid high‐precision analytical method for triple oxygen isotope analysis of CO(2) gas using tunable infrared laser direct absorption spectroscopy
title_full_unstemmed A rapid high‐precision analytical method for triple oxygen isotope analysis of CO(2) gas using tunable infrared laser direct absorption spectroscopy
title_short A rapid high‐precision analytical method for triple oxygen isotope analysis of CO(2) gas using tunable infrared laser direct absorption spectroscopy
title_sort rapid high‐precision analytical method for triple oxygen isotope analysis of co(2) gas using tunable infrared laser direct absorption spectroscopy
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9541814/
https://www.ncbi.nlm.nih.gov/pubmed/36056818
http://dx.doi.org/10.1002/rcm.9391
work_keys_str_mv AT perduenathan arapidhighprecisionanalyticalmethodfortripleoxygenisotopeanalysisofco2gasusingtunableinfraredlaserdirectabsorptionspectroscopy
AT sharpzachary arapidhighprecisionanalyticalmethodfortripleoxygenisotopeanalysisofco2gasusingtunableinfraredlaserdirectabsorptionspectroscopy
AT nelsondavid arapidhighprecisionanalyticalmethodfortripleoxygenisotopeanalysisofco2gasusingtunableinfraredlaserdirectabsorptionspectroscopy
AT wehrrick arapidhighprecisionanalyticalmethodfortripleoxygenisotopeanalysisofco2gasusingtunableinfraredlaserdirectabsorptionspectroscopy
AT dyroffchristoph arapidhighprecisionanalyticalmethodfortripleoxygenisotopeanalysisofco2gasusingtunableinfraredlaserdirectabsorptionspectroscopy
AT perduenathan rapidhighprecisionanalyticalmethodfortripleoxygenisotopeanalysisofco2gasusingtunableinfraredlaserdirectabsorptionspectroscopy
AT sharpzachary rapidhighprecisionanalyticalmethodfortripleoxygenisotopeanalysisofco2gasusingtunableinfraredlaserdirectabsorptionspectroscopy
AT nelsondavid rapidhighprecisionanalyticalmethodfortripleoxygenisotopeanalysisofco2gasusingtunableinfraredlaserdirectabsorptionspectroscopy
AT wehrrick rapidhighprecisionanalyticalmethodfortripleoxygenisotopeanalysisofco2gasusingtunableinfraredlaserdirectabsorptionspectroscopy
AT dyroffchristoph rapidhighprecisionanalyticalmethodfortripleoxygenisotopeanalysisofco2gasusingtunableinfraredlaserdirectabsorptionspectroscopy