Cargando…

Stentectomy of a Balloon-Mounted Stent From Vertebrobasilar Circulation: A Technical Report and Literature Review

Stents are being widely used in the neuroendovascular field more often for assisted coiling of aneurysms and treatment of atherosclerotic stenosis. Stent detachment and embolization are one of the most feared complications associated with poor clinical outcomes. Many techniques have been detailed in...

Descripción completa

Detalles Bibliográficos
Autores principales: Chakravarthi, Sudheer, Pasya, Sai Kumar Reddy, Gorijala, Vamsi Krishna, Guntamukkala, Anusha, Sajja, Kalyan Chakravarthy
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9541846/
https://www.ncbi.nlm.nih.gov/pubmed/36225486
http://dx.doi.org/10.7759/cureus.28956
_version_ 1784804015807135744
author Chakravarthi, Sudheer
Pasya, Sai Kumar Reddy
Gorijala, Vamsi Krishna
Guntamukkala, Anusha
Sajja, Kalyan Chakravarthy
author_facet Chakravarthi, Sudheer
Pasya, Sai Kumar Reddy
Gorijala, Vamsi Krishna
Guntamukkala, Anusha
Sajja, Kalyan Chakravarthy
author_sort Chakravarthi, Sudheer
collection PubMed
description Stents are being widely used in the neuroendovascular field more often for assisted coiling of aneurysms and treatment of atherosclerotic stenosis. Stent detachment and embolization are one of the most feared complications associated with poor clinical outcomes. Many techniques have been detailed in the literature for extracting such dislodged stents. We describe a case of retrieval of an inadvertently detached balloon-mounted stent from the intracranial left vertebral artery. This occurred in a 58-year-old male patient with a history of diabetes mellitus whose stenting procedure was planned for severe intracranial atherosclerotic disease of bilateral vertebral arteries causing recurrent posterior circulation ischemic events. Stentectomy was performed successfully using a stent retriever. Intracranial vertebral artery stenting was eventually accomplished with excellent clinical outcomes.
format Online
Article
Text
id pubmed-9541846
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-95418462022-10-11 Stentectomy of a Balloon-Mounted Stent From Vertebrobasilar Circulation: A Technical Report and Literature Review Chakravarthi, Sudheer Pasya, Sai Kumar Reddy Gorijala, Vamsi Krishna Guntamukkala, Anusha Sajja, Kalyan Chakravarthy Cureus Cardiac/Thoracic/Vascular Surgery Stents are being widely used in the neuroendovascular field more often for assisted coiling of aneurysms and treatment of atherosclerotic stenosis. Stent detachment and embolization are one of the most feared complications associated with poor clinical outcomes. Many techniques have been detailed in the literature for extracting such dislodged stents. We describe a case of retrieval of an inadvertently detached balloon-mounted stent from the intracranial left vertebral artery. This occurred in a 58-year-old male patient with a history of diabetes mellitus whose stenting procedure was planned for severe intracranial atherosclerotic disease of bilateral vertebral arteries causing recurrent posterior circulation ischemic events. Stentectomy was performed successfully using a stent retriever. Intracranial vertebral artery stenting was eventually accomplished with excellent clinical outcomes. Cureus 2022-09-08 /pmc/articles/PMC9541846/ /pubmed/36225486 http://dx.doi.org/10.7759/cureus.28956 Text en Copyright © 2022, Chakravarthi et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Cardiac/Thoracic/Vascular Surgery
Chakravarthi, Sudheer
Pasya, Sai Kumar Reddy
Gorijala, Vamsi Krishna
Guntamukkala, Anusha
Sajja, Kalyan Chakravarthy
Stentectomy of a Balloon-Mounted Stent From Vertebrobasilar Circulation: A Technical Report and Literature Review
title Stentectomy of a Balloon-Mounted Stent From Vertebrobasilar Circulation: A Technical Report and Literature Review
title_full Stentectomy of a Balloon-Mounted Stent From Vertebrobasilar Circulation: A Technical Report and Literature Review
title_fullStr Stentectomy of a Balloon-Mounted Stent From Vertebrobasilar Circulation: A Technical Report and Literature Review
title_full_unstemmed Stentectomy of a Balloon-Mounted Stent From Vertebrobasilar Circulation: A Technical Report and Literature Review
title_short Stentectomy of a Balloon-Mounted Stent From Vertebrobasilar Circulation: A Technical Report and Literature Review
title_sort stentectomy of a balloon-mounted stent from vertebrobasilar circulation: a technical report and literature review
topic Cardiac/Thoracic/Vascular Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9541846/
https://www.ncbi.nlm.nih.gov/pubmed/36225486
http://dx.doi.org/10.7759/cureus.28956
work_keys_str_mv AT chakravarthisudheer stentectomyofaballoonmountedstentfromvertebrobasilarcirculationatechnicalreportandliteraturereview
AT pasyasaikumarreddy stentectomyofaballoonmountedstentfromvertebrobasilarcirculationatechnicalreportandliteraturereview
AT gorijalavamsikrishna stentectomyofaballoonmountedstentfromvertebrobasilarcirculationatechnicalreportandliteraturereview
AT guntamukkalaanusha stentectomyofaballoonmountedstentfromvertebrobasilarcirculationatechnicalreportandliteraturereview
AT sajjakalyanchakravarthy stentectomyofaballoonmountedstentfromvertebrobasilarcirculationatechnicalreportandliteraturereview