Comprehensive evaluation of dosimetric impact against position errors in accelerator‐based BNCT under different treatment parameter settings

BACKGROUND: Patients who undergo accelerator‐based (AB) boron neutron capture therapy (BNCT) for head and neck cancer in the sitting position are generally uncomfortably immobilized, and patient motion during this treatment may be greater than that in other radiotherapy techniques. Furthermore, the...

Descripción completa

Detalles Bibliográficos
Autores principales: Kakino, Ryo, Hu, Naonori, Isohashi, Kayako, Aihara, Teruhito, Nihei, Keiji, Ono, Koji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9541895/
https://www.ncbi.nlm.nih.gov/pubmed/35758307
http://dx.doi.org/10.1002/mp.15823
_version_ 1784804027540701184
author Kakino, Ryo
Hu, Naonori
Isohashi, Kayako
Aihara, Teruhito
Nihei, Keiji
Ono, Koji
author_facet Kakino, Ryo
Hu, Naonori
Isohashi, Kayako
Aihara, Teruhito
Nihei, Keiji
Ono, Koji
author_sort Kakino, Ryo
collection PubMed
description BACKGROUND: Patients who undergo accelerator‐based (AB) boron neutron capture therapy (BNCT) for head and neck cancer in the sitting position are generally uncomfortably immobilized, and patient motion during this treatment may be greater than that in other radiotherapy techniques. Furthermore, the treatment time of BNCT is relatively long (up to approximately 1 h), which increases the possibility of patient movement during treatment. As most BNCT irradiations are performed in a single fraction, the dosimetric error due to patient motion is of greater consequence and needs to be evaluated and accounted for. Several treatment parameters are required for BNCT dose calculation. PURPOSE: To investigate the dosimetric impacts (DIs) against position errors using a simple cylindrical phantom for an AB‐BNCT system under different treatment parameter settings. METHODS: The treatment plans were created in RayStation and the dose calculation was performed using the NeuCure® dose engine. A cylindrical phantom (16 cm diameter × 20 cm height) made of soft tissue was modeled. Dummy tumors in the form of a 3‐cm‐diameter sphere were arranged at depths of 2.5 and 6.5 cm (denoted by T (2.5) and T (6.5), respectively). Reference plans were created by setting the following parameters: collimator size = 10, 12, or 15 cm in diameter, collimator‐to‐surface distance (CSD) = 4.0 or 8.0 cm, tumor‐to‐blood ratio (T/B ratio) using (18)F‐fluoro‐borono‐phenylalanine = 2.5 or 5.0, and (10)B concentration in blood = 20, 25, or 30 ppm. The prescribed dose was D (95%) ≥ 20 Gy‐eq for both T (2.5) and T (6.5). Based on the reference plans, phantom‐shifted plans were created in 26 directions [all combinations of left–right (LR), anterior–posterior (AP), and superior–inferior (SI) directions) and three distances (1.0, 2.0, and 3.0 cm). The DIs were evaluated at D (80%) of the tumors. The shift direction dependency of the DI in the LR, AP, and SI directions was evaluated by conducting a multiple regression analysis (MRA) and other analyses where required. RESULTS: The coefficients of the MRA of the DIs for LR, AP, and SI shifts were −0.08, 2.16, and −0.04 (p‐values = 0.084, <0.01, and 0.334) for T (2.5) and −0.05, 2.08, and 0.15 (p‐values = 0.526, <0.01, and 0.065) for T (6.5), respectively. The analysis of variance showed that DIs due to the AP shift were significantly greater for smaller collimator sizes on T (2.5) and smaller CSD on T (6.5). Dose reduction due to SI or LR (lateral) shifts was significantly greater for smaller collimator sizes on both T (2.5) and T (6.5) and smaller CSD on T(2.5), according to the Student's t‐test. There were no significant differences in the DIs against both the AP shift and the lateral shift between the different T/B ratios and (10)B concentrations. CONCLUSION: The DIs were largely affected by the shift in the AP direction and were influenced by the different treatment parameters.
format Online
Article
Text
id pubmed-9541895
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-95418952022-10-14 Comprehensive evaluation of dosimetric impact against position errors in accelerator‐based BNCT under different treatment parameter settings Kakino, Ryo Hu, Naonori Isohashi, Kayako Aihara, Teruhito Nihei, Keiji Ono, Koji Med Phys THERAPEUTIC INTERVENTIONS BACKGROUND: Patients who undergo accelerator‐based (AB) boron neutron capture therapy (BNCT) for head and neck cancer in the sitting position are generally uncomfortably immobilized, and patient motion during this treatment may be greater than that in other radiotherapy techniques. Furthermore, the treatment time of BNCT is relatively long (up to approximately 1 h), which increases the possibility of patient movement during treatment. As most BNCT irradiations are performed in a single fraction, the dosimetric error due to patient motion is of greater consequence and needs to be evaluated and accounted for. Several treatment parameters are required for BNCT dose calculation. PURPOSE: To investigate the dosimetric impacts (DIs) against position errors using a simple cylindrical phantom for an AB‐BNCT system under different treatment parameter settings. METHODS: The treatment plans were created in RayStation and the dose calculation was performed using the NeuCure® dose engine. A cylindrical phantom (16 cm diameter × 20 cm height) made of soft tissue was modeled. Dummy tumors in the form of a 3‐cm‐diameter sphere were arranged at depths of 2.5 and 6.5 cm (denoted by T (2.5) and T (6.5), respectively). Reference plans were created by setting the following parameters: collimator size = 10, 12, or 15 cm in diameter, collimator‐to‐surface distance (CSD) = 4.0 or 8.0 cm, tumor‐to‐blood ratio (T/B ratio) using (18)F‐fluoro‐borono‐phenylalanine = 2.5 or 5.0, and (10)B concentration in blood = 20, 25, or 30 ppm. The prescribed dose was D (95%) ≥ 20 Gy‐eq for both T (2.5) and T (6.5). Based on the reference plans, phantom‐shifted plans were created in 26 directions [all combinations of left–right (LR), anterior–posterior (AP), and superior–inferior (SI) directions) and three distances (1.0, 2.0, and 3.0 cm). The DIs were evaluated at D (80%) of the tumors. The shift direction dependency of the DI in the LR, AP, and SI directions was evaluated by conducting a multiple regression analysis (MRA) and other analyses where required. RESULTS: The coefficients of the MRA of the DIs for LR, AP, and SI shifts were −0.08, 2.16, and −0.04 (p‐values = 0.084, <0.01, and 0.334) for T (2.5) and −0.05, 2.08, and 0.15 (p‐values = 0.526, <0.01, and 0.065) for T (6.5), respectively. The analysis of variance showed that DIs due to the AP shift were significantly greater for smaller collimator sizes on T (2.5) and smaller CSD on T (6.5). Dose reduction due to SI or LR (lateral) shifts was significantly greater for smaller collimator sizes on both T (2.5) and T (6.5) and smaller CSD on T(2.5), according to the Student's t‐test. There were no significant differences in the DIs against both the AP shift and the lateral shift between the different T/B ratios and (10)B concentrations. CONCLUSION: The DIs were largely affected by the shift in the AP direction and were influenced by the different treatment parameters. John Wiley and Sons Inc. 2022-07-04 2022-08 /pmc/articles/PMC9541895/ /pubmed/35758307 http://dx.doi.org/10.1002/mp.15823 Text en © 2022 The Authors. Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle THERAPEUTIC INTERVENTIONS
Kakino, Ryo
Hu, Naonori
Isohashi, Kayako
Aihara, Teruhito
Nihei, Keiji
Ono, Koji
Comprehensive evaluation of dosimetric impact against position errors in accelerator‐based BNCT under different treatment parameter settings
title Comprehensive evaluation of dosimetric impact against position errors in accelerator‐based BNCT under different treatment parameter settings
title_full Comprehensive evaluation of dosimetric impact against position errors in accelerator‐based BNCT under different treatment parameter settings
title_fullStr Comprehensive evaluation of dosimetric impact against position errors in accelerator‐based BNCT under different treatment parameter settings
title_full_unstemmed Comprehensive evaluation of dosimetric impact against position errors in accelerator‐based BNCT under different treatment parameter settings
title_short Comprehensive evaluation of dosimetric impact against position errors in accelerator‐based BNCT under different treatment parameter settings
title_sort comprehensive evaluation of dosimetric impact against position errors in accelerator‐based bnct under different treatment parameter settings
topic THERAPEUTIC INTERVENTIONS
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9541895/
https://www.ncbi.nlm.nih.gov/pubmed/35758307
http://dx.doi.org/10.1002/mp.15823
work_keys_str_mv AT kakinoryo comprehensiveevaluationofdosimetricimpactagainstpositionerrorsinacceleratorbasedbnctunderdifferenttreatmentparametersettings
AT hunaonori comprehensiveevaluationofdosimetricimpactagainstpositionerrorsinacceleratorbasedbnctunderdifferenttreatmentparametersettings
AT isohashikayako comprehensiveevaluationofdosimetricimpactagainstpositionerrorsinacceleratorbasedbnctunderdifferenttreatmentparametersettings
AT aiharateruhito comprehensiveevaluationofdosimetricimpactagainstpositionerrorsinacceleratorbasedbnctunderdifferenttreatmentparametersettings
AT niheikeiji comprehensiveevaluationofdosimetricimpactagainstpositionerrorsinacceleratorbasedbnctunderdifferenttreatmentparametersettings
AT onokoji comprehensiveevaluationofdosimetricimpactagainstpositionerrorsinacceleratorbasedbnctunderdifferenttreatmentparametersettings