In vitro quality and hemostatic function of cold‐stored CPDA‐1 whole blood after repeated transient exposure to 28°C storage temperature

BACKGROUND: Blood products are frequently exposed to room temperature or higher for longer periods than permitted by policy. We aimed to investigate if this resulted in a measurable effect on common quality parameters and viscoelastic hemostatic function of cold stored CPDA‐1 whole blood. STUDY DESI...

Descripción completa

Detalles Bibliográficos
Autores principales: Sivertsen, Joar, Hervig, Tor, Strandenes, Geir, Kristoffersen, Einar K., Braathen, Hanne, Apelseth, Torunn O.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9541954/
https://www.ncbi.nlm.nih.gov/pubmed/35748681
http://dx.doi.org/10.1111/trf.16970
_version_ 1784804042105421824
author Sivertsen, Joar
Hervig, Tor
Strandenes, Geir
Kristoffersen, Einar K.
Braathen, Hanne
Apelseth, Torunn O.
author_facet Sivertsen, Joar
Hervig, Tor
Strandenes, Geir
Kristoffersen, Einar K.
Braathen, Hanne
Apelseth, Torunn O.
author_sort Sivertsen, Joar
collection PubMed
description BACKGROUND: Blood products are frequently exposed to room temperature or higher for longer periods than permitted by policy. We aimed to investigate if this resulted in a measurable effect on common quality parameters and viscoelastic hemostatic function of cold stored CPDA‐1 whole blood. STUDY DESIGN AND METHODS: 450 ml of whole blood from 16 O Rh(D) positive donors was collected in 63 ml of CPDA‐1 and stored cold. Eights bags were exposed to five weekly 4‐h long transient temperature changes to 28°C. Eight bags were stored continuously at 4°C as a control. Samples were collected at baseline on day 1, after the first cycle on day 1 and weekly before each subsequent cycle (day 7, 14, 21, 28 and 35). Hemolysis, hematological parameters, pH, glucose, lactate, potassium, thromboelastography, INR, APTT, fibrinogen, and factor VIII were measured. RESULTS: CPDA‐1 whole blood repeatedly exposed to 28°C did not show reduced quality compared to the control group on day 35. Two units in the test group had hemolysis of 1.1% and 1.2%, and two in the control group hemolysis of 0.8%. Remaining thromboelastography clot strength (MA) on day 35 was 51.7 mm (44.8, 58.6) in the test group and 46.1 (41.6, 50.6) in the control group (p = .023). Platelet count was better preserved in the test group (166.7 [137.8, 195.6] vs. 117.8 [90.3, 145.2], p = .018). One sample in the test group was positive for Cutibacterium acnes on day 35 + 6. CONCLUSION: Hemolysis findings warrant further investigation. Other indicators of quality were not negatively affected.
format Online
Article
Text
id pubmed-9541954
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-95419542022-10-14 In vitro quality and hemostatic function of cold‐stored CPDA‐1 whole blood after repeated transient exposure to 28°C storage temperature Sivertsen, Joar Hervig, Tor Strandenes, Geir Kristoffersen, Einar K. Braathen, Hanne Apelseth, Torunn O. Transfusion Low Titer Group O Whole Blood BACKGROUND: Blood products are frequently exposed to room temperature or higher for longer periods than permitted by policy. We aimed to investigate if this resulted in a measurable effect on common quality parameters and viscoelastic hemostatic function of cold stored CPDA‐1 whole blood. STUDY DESIGN AND METHODS: 450 ml of whole blood from 16 O Rh(D) positive donors was collected in 63 ml of CPDA‐1 and stored cold. Eights bags were exposed to five weekly 4‐h long transient temperature changes to 28°C. Eight bags were stored continuously at 4°C as a control. Samples were collected at baseline on day 1, after the first cycle on day 1 and weekly before each subsequent cycle (day 7, 14, 21, 28 and 35). Hemolysis, hematological parameters, pH, glucose, lactate, potassium, thromboelastography, INR, APTT, fibrinogen, and factor VIII were measured. RESULTS: CPDA‐1 whole blood repeatedly exposed to 28°C did not show reduced quality compared to the control group on day 35. Two units in the test group had hemolysis of 1.1% and 1.2%, and two in the control group hemolysis of 0.8%. Remaining thromboelastography clot strength (MA) on day 35 was 51.7 mm (44.8, 58.6) in the test group and 46.1 (41.6, 50.6) in the control group (p = .023). Platelet count was better preserved in the test group (166.7 [137.8, 195.6] vs. 117.8 [90.3, 145.2], p = .018). One sample in the test group was positive for Cutibacterium acnes on day 35 + 6. CONCLUSION: Hemolysis findings warrant further investigation. Other indicators of quality were not negatively affected. John Wiley & Sons, Inc. 2022-06-24 2022-08 /pmc/articles/PMC9541954/ /pubmed/35748681 http://dx.doi.org/10.1111/trf.16970 Text en © 2022 The Authors. Transfusion published by Wiley Periodicals LLC on behalf of AABB. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Low Titer Group O Whole Blood
Sivertsen, Joar
Hervig, Tor
Strandenes, Geir
Kristoffersen, Einar K.
Braathen, Hanne
Apelseth, Torunn O.
In vitro quality and hemostatic function of cold‐stored CPDA‐1 whole blood after repeated transient exposure to 28°C storage temperature
title In vitro quality and hemostatic function of cold‐stored CPDA‐1 whole blood after repeated transient exposure to 28°C storage temperature
title_full In vitro quality and hemostatic function of cold‐stored CPDA‐1 whole blood after repeated transient exposure to 28°C storage temperature
title_fullStr In vitro quality and hemostatic function of cold‐stored CPDA‐1 whole blood after repeated transient exposure to 28°C storage temperature
title_full_unstemmed In vitro quality and hemostatic function of cold‐stored CPDA‐1 whole blood after repeated transient exposure to 28°C storage temperature
title_short In vitro quality and hemostatic function of cold‐stored CPDA‐1 whole blood after repeated transient exposure to 28°C storage temperature
title_sort in vitro quality and hemostatic function of cold‐stored cpda‐1 whole blood after repeated transient exposure to 28°c storage temperature
topic Low Titer Group O Whole Blood
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9541954/
https://www.ncbi.nlm.nih.gov/pubmed/35748681
http://dx.doi.org/10.1111/trf.16970
work_keys_str_mv AT sivertsenjoar invitroqualityandhemostaticfunctionofcoldstoredcpda1wholebloodafterrepeatedtransientexposureto28cstoragetemperature
AT hervigtor invitroqualityandhemostaticfunctionofcoldstoredcpda1wholebloodafterrepeatedtransientexposureto28cstoragetemperature
AT strandenesgeir invitroqualityandhemostaticfunctionofcoldstoredcpda1wholebloodafterrepeatedtransientexposureto28cstoragetemperature
AT kristofferseneinark invitroqualityandhemostaticfunctionofcoldstoredcpda1wholebloodafterrepeatedtransientexposureto28cstoragetemperature
AT braathenhanne invitroqualityandhemostaticfunctionofcoldstoredcpda1wholebloodafterrepeatedtransientexposureto28cstoragetemperature
AT apelsethtorunno invitroqualityandhemostaticfunctionofcoldstoredcpda1wholebloodafterrepeatedtransientexposureto28cstoragetemperature