Cargando…

Interleaved and simultaneous multi‐nuclear magnetic resonance in vivo. Review of principles, applications and potential

Magnetic resonance signals from different nuclei can be excited or received at the same time,rendering simultaneous or rapidly interleaved multi‐nuclear acquisitions feasible. The advan‐tages are a reduction of total scan time compared to sequential multi‐nuclear acquisitions or that additional info...

Descripción completa

Detalles Bibliográficos
Autores principales: Lopez Kolkovsky, Alfredo L., Carlier, Pierre G., Marty, Benjamin, Meyerspeer, Martin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9542607/
https://www.ncbi.nlm.nih.gov/pubmed/35352440
http://dx.doi.org/10.1002/nbm.4735
_version_ 1784804188907110400
author Lopez Kolkovsky, Alfredo L.
Carlier, Pierre G.
Marty, Benjamin
Meyerspeer, Martin
author_facet Lopez Kolkovsky, Alfredo L.
Carlier, Pierre G.
Marty, Benjamin
Meyerspeer, Martin
author_sort Lopez Kolkovsky, Alfredo L.
collection PubMed
description Magnetic resonance signals from different nuclei can be excited or received at the same time,rendering simultaneous or rapidly interleaved multi‐nuclear acquisitions feasible. The advan‐tages are a reduction of total scan time compared to sequential multi‐nuclear acquisitions or that additional information from heteronuclear data is obtained at thesame time and anatomical position. Information content can be qualitatively increased by delivering a more comprehensive MR‐based picture of a transient state (such as an exercise bout). Also, combiningnon‐proton MR acquisitions with (1)Hinformation (e.g., dynamic shim updates and motion correction) can be used to improve data quality during long scans and benefits image coregistration. This work reviews the literature on interleaved and simultaneous multi‐nuclear MRI and MRS in vivo. Prominent use cases for this methodology in clinical and research applications are brain and muscle, but studies have also been carried out in other targets, including the lung, knee, breast and heart. Simultaneous multi‐nuclear measurements in the liver and kidney have also been performed, but exclusively in rodents. In this review, a consistent nomenclature is proposed, to help clarify the terminology used for this principle throughout the literature on in‐vivo MR. An overview covers the basic principles, the technical requirements on the MR scanner and the implementations realised either by MR system vendors or research groups, from the early days until today. Considerations regarding the multi‐tuned RF coils required and heteronuclear polarisation interactions are briefly discussed, and fields for future in‐vivo applications for interleaved multi‐nuclear MR pulse sequences are identified.
format Online
Article
Text
id pubmed-9542607
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-95426072022-10-14 Interleaved and simultaneous multi‐nuclear magnetic resonance in vivo. Review of principles, applications and potential Lopez Kolkovsky, Alfredo L. Carlier, Pierre G. Marty, Benjamin Meyerspeer, Martin NMR Biomed Review Article Magnetic resonance signals from different nuclei can be excited or received at the same time,rendering simultaneous or rapidly interleaved multi‐nuclear acquisitions feasible. The advan‐tages are a reduction of total scan time compared to sequential multi‐nuclear acquisitions or that additional information from heteronuclear data is obtained at thesame time and anatomical position. Information content can be qualitatively increased by delivering a more comprehensive MR‐based picture of a transient state (such as an exercise bout). Also, combiningnon‐proton MR acquisitions with (1)Hinformation (e.g., dynamic shim updates and motion correction) can be used to improve data quality during long scans and benefits image coregistration. This work reviews the literature on interleaved and simultaneous multi‐nuclear MRI and MRS in vivo. Prominent use cases for this methodology in clinical and research applications are brain and muscle, but studies have also been carried out in other targets, including the lung, knee, breast and heart. Simultaneous multi‐nuclear measurements in the liver and kidney have also been performed, but exclusively in rodents. In this review, a consistent nomenclature is proposed, to help clarify the terminology used for this principle throughout the literature on in‐vivo MR. An overview covers the basic principles, the technical requirements on the MR scanner and the implementations realised either by MR system vendors or research groups, from the early days until today. Considerations regarding the multi‐tuned RF coils required and heteronuclear polarisation interactions are briefly discussed, and fields for future in‐vivo applications for interleaved multi‐nuclear MR pulse sequences are identified. John Wiley and Sons Inc. 2022-04-27 2022-10 /pmc/articles/PMC9542607/ /pubmed/35352440 http://dx.doi.org/10.1002/nbm.4735 Text en © 2022 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Lopez Kolkovsky, Alfredo L.
Carlier, Pierre G.
Marty, Benjamin
Meyerspeer, Martin
Interleaved and simultaneous multi‐nuclear magnetic resonance in vivo. Review of principles, applications and potential
title Interleaved and simultaneous multi‐nuclear magnetic resonance in vivo. Review of principles, applications and potential
title_full Interleaved and simultaneous multi‐nuclear magnetic resonance in vivo. Review of principles, applications and potential
title_fullStr Interleaved and simultaneous multi‐nuclear magnetic resonance in vivo. Review of principles, applications and potential
title_full_unstemmed Interleaved and simultaneous multi‐nuclear magnetic resonance in vivo. Review of principles, applications and potential
title_short Interleaved and simultaneous multi‐nuclear magnetic resonance in vivo. Review of principles, applications and potential
title_sort interleaved and simultaneous multi‐nuclear magnetic resonance in vivo. review of principles, applications and potential
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9542607/
https://www.ncbi.nlm.nih.gov/pubmed/35352440
http://dx.doi.org/10.1002/nbm.4735
work_keys_str_mv AT lopezkolkovskyalfredol interleavedandsimultaneousmultinuclearmagneticresonanceinvivoreviewofprinciplesapplicationsandpotential
AT carlierpierreg interleavedandsimultaneousmultinuclearmagneticresonanceinvivoreviewofprinciplesapplicationsandpotential
AT martybenjamin interleavedandsimultaneousmultinuclearmagneticresonanceinvivoreviewofprinciplesapplicationsandpotential
AT meyerspeermartin interleavedandsimultaneousmultinuclearmagneticresonanceinvivoreviewofprinciplesapplicationsandpotential