Cargando…

Long-term Consequences of Ventricular Septal Defect Closure Using Nit-Occlud Le VSD Coil Device: A Systematic Review and Meta-Analysis

BACKGROUND: The successful management of ventricular septal defect (VSD) has been possible through the development of advanced techniques. In this regard, percutaneous VSD closure by employing different types of occluders as an alternative for surgery can help to achieve the most desirable postproce...

Descripción completa

Detalles Bibliográficos
Autores principales: Ghaderian, Mehdi, Shahsanaei, Farzad, Behdad, Samin, Mozafari, Safura
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9542967/
https://www.ncbi.nlm.nih.gov/pubmed/36213425
http://dx.doi.org/10.4103/heartviews.heartviews_97_21
_version_ 1784804266326622208
author Ghaderian, Mehdi
Shahsanaei, Farzad
Behdad, Samin
Mozafari, Safura
author_facet Ghaderian, Mehdi
Shahsanaei, Farzad
Behdad, Samin
Mozafari, Safura
author_sort Ghaderian, Mehdi
collection PubMed
description BACKGROUND: The successful management of ventricular septal defect (VSD) has been possible through the development of advanced techniques. In this regard, percutaneous VSD closure by employing different types of occluders as an alternative for surgery can help to achieve the most desirable postprocedural consequences. However, the studies reported contradictory results on the use of different brands of VSD occluders. Herein, we performed a systematic review and meta-analysis of published studies to assess pooled long-term success rate and potential complications of using the Nit-Occlud Lê VSD coil for VSD closure. MATERIALS AND METHODS: Two reviewers began to deeply search the various databases for all eligible studies in accordance with the considered keywords. The inclusion criterion for retrieving the studies was to describe the mid-term or long-term consequences of VSD closing by the Nit-Occlud Lê VSD coil device. In the final, eight articles were eligible for the analysis. The follow-up time of the studies ranged from 6 months to 5 years. RESULTS: The success rate of the procedure ranged from 87.0% to 100% considering the weight of each study, the pooled success rate of VSDs closure by Nit-Occlud Lê VSD coil device was 93.1% (95% confidence interval [CI]: 89.9% to 95.5%). The pooled prevalence of postprocedural residual shunt was estimated to be 9.6% (95%CI: 6.8% to 13.4%). The corrected pooled prevalence of trivial mild aortic regurgitation (AR) was 2.9% (95%CI: 1.5% to 5.4%); however, moderate-to-severe AR and complete heart block or right bundle branch block were shown to be rare. CONCLUSION: VSD closure using a Nit-Occlud Lê VSD coil device can lead to a high success rate with low rates of residual shunt, cardiac conductive or vascular disturbances.
format Online
Article
Text
id pubmed-9542967
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-95429672022-10-08 Long-term Consequences of Ventricular Septal Defect Closure Using Nit-Occlud Le VSD Coil Device: A Systematic Review and Meta-Analysis Ghaderian, Mehdi Shahsanaei, Farzad Behdad, Samin Mozafari, Safura Heart Views Review Article BACKGROUND: The successful management of ventricular septal defect (VSD) has been possible through the development of advanced techniques. In this regard, percutaneous VSD closure by employing different types of occluders as an alternative for surgery can help to achieve the most desirable postprocedural consequences. However, the studies reported contradictory results on the use of different brands of VSD occluders. Herein, we performed a systematic review and meta-analysis of published studies to assess pooled long-term success rate and potential complications of using the Nit-Occlud Lê VSD coil for VSD closure. MATERIALS AND METHODS: Two reviewers began to deeply search the various databases for all eligible studies in accordance with the considered keywords. The inclusion criterion for retrieving the studies was to describe the mid-term or long-term consequences of VSD closing by the Nit-Occlud Lê VSD coil device. In the final, eight articles were eligible for the analysis. The follow-up time of the studies ranged from 6 months to 5 years. RESULTS: The success rate of the procedure ranged from 87.0% to 100% considering the weight of each study, the pooled success rate of VSDs closure by Nit-Occlud Lê VSD coil device was 93.1% (95% confidence interval [CI]: 89.9% to 95.5%). The pooled prevalence of postprocedural residual shunt was estimated to be 9.6% (95%CI: 6.8% to 13.4%). The corrected pooled prevalence of trivial mild aortic regurgitation (AR) was 2.9% (95%CI: 1.5% to 5.4%); however, moderate-to-severe AR and complete heart block or right bundle branch block were shown to be rare. CONCLUSION: VSD closure using a Nit-Occlud Lê VSD coil device can lead to a high success rate with low rates of residual shunt, cardiac conductive or vascular disturbances. Wolters Kluwer - Medknow 2022 2022-07-23 /pmc/articles/PMC9542967/ /pubmed/36213425 http://dx.doi.org/10.4103/heartviews.heartviews_97_21 Text en Copyright: © 2022 Heart Views https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Review Article
Ghaderian, Mehdi
Shahsanaei, Farzad
Behdad, Samin
Mozafari, Safura
Long-term Consequences of Ventricular Septal Defect Closure Using Nit-Occlud Le VSD Coil Device: A Systematic Review and Meta-Analysis
title Long-term Consequences of Ventricular Septal Defect Closure Using Nit-Occlud Le VSD Coil Device: A Systematic Review and Meta-Analysis
title_full Long-term Consequences of Ventricular Septal Defect Closure Using Nit-Occlud Le VSD Coil Device: A Systematic Review and Meta-Analysis
title_fullStr Long-term Consequences of Ventricular Septal Defect Closure Using Nit-Occlud Le VSD Coil Device: A Systematic Review and Meta-Analysis
title_full_unstemmed Long-term Consequences of Ventricular Septal Defect Closure Using Nit-Occlud Le VSD Coil Device: A Systematic Review and Meta-Analysis
title_short Long-term Consequences of Ventricular Septal Defect Closure Using Nit-Occlud Le VSD Coil Device: A Systematic Review and Meta-Analysis
title_sort long-term consequences of ventricular septal defect closure using nit-occlud le vsd coil device: a systematic review and meta-analysis
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9542967/
https://www.ncbi.nlm.nih.gov/pubmed/36213425
http://dx.doi.org/10.4103/heartviews.heartviews_97_21
work_keys_str_mv AT ghaderianmehdi longtermconsequencesofventricularseptaldefectclosureusingnitoccludlevsdcoildeviceasystematicreviewandmetaanalysis
AT shahsanaeifarzad longtermconsequencesofventricularseptaldefectclosureusingnitoccludlevsdcoildeviceasystematicreviewandmetaanalysis
AT behdadsamin longtermconsequencesofventricularseptaldefectclosureusingnitoccludlevsdcoildeviceasystematicreviewandmetaanalysis
AT mozafarisafura longtermconsequencesofventricularseptaldefectclosureusingnitoccludlevsdcoildeviceasystematicreviewandmetaanalysis