Cargando…
Long-term Consequences of Ventricular Septal Defect Closure Using Nit-Occlud Le VSD Coil Device: A Systematic Review and Meta-Analysis
BACKGROUND: The successful management of ventricular septal defect (VSD) has been possible through the development of advanced techniques. In this regard, percutaneous VSD closure by employing different types of occluders as an alternative for surgery can help to achieve the most desirable postproce...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9542967/ https://www.ncbi.nlm.nih.gov/pubmed/36213425 http://dx.doi.org/10.4103/heartviews.heartviews_97_21 |
_version_ | 1784804266326622208 |
---|---|
author | Ghaderian, Mehdi Shahsanaei, Farzad Behdad, Samin Mozafari, Safura |
author_facet | Ghaderian, Mehdi Shahsanaei, Farzad Behdad, Samin Mozafari, Safura |
author_sort | Ghaderian, Mehdi |
collection | PubMed |
description | BACKGROUND: The successful management of ventricular septal defect (VSD) has been possible through the development of advanced techniques. In this regard, percutaneous VSD closure by employing different types of occluders as an alternative for surgery can help to achieve the most desirable postprocedural consequences. However, the studies reported contradictory results on the use of different brands of VSD occluders. Herein, we performed a systematic review and meta-analysis of published studies to assess pooled long-term success rate and potential complications of using the Nit-Occlud Lê VSD coil for VSD closure. MATERIALS AND METHODS: Two reviewers began to deeply search the various databases for all eligible studies in accordance with the considered keywords. The inclusion criterion for retrieving the studies was to describe the mid-term or long-term consequences of VSD closing by the Nit-Occlud Lê VSD coil device. In the final, eight articles were eligible for the analysis. The follow-up time of the studies ranged from 6 months to 5 years. RESULTS: The success rate of the procedure ranged from 87.0% to 100% considering the weight of each study, the pooled success rate of VSDs closure by Nit-Occlud Lê VSD coil device was 93.1% (95% confidence interval [CI]: 89.9% to 95.5%). The pooled prevalence of postprocedural residual shunt was estimated to be 9.6% (95%CI: 6.8% to 13.4%). The corrected pooled prevalence of trivial mild aortic regurgitation (AR) was 2.9% (95%CI: 1.5% to 5.4%); however, moderate-to-severe AR and complete heart block or right bundle branch block were shown to be rare. CONCLUSION: VSD closure using a Nit-Occlud Lê VSD coil device can lead to a high success rate with low rates of residual shunt, cardiac conductive or vascular disturbances. |
format | Online Article Text |
id | pubmed-9542967 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-95429672022-10-08 Long-term Consequences of Ventricular Septal Defect Closure Using Nit-Occlud Le VSD Coil Device: A Systematic Review and Meta-Analysis Ghaderian, Mehdi Shahsanaei, Farzad Behdad, Samin Mozafari, Safura Heart Views Review Article BACKGROUND: The successful management of ventricular septal defect (VSD) has been possible through the development of advanced techniques. In this regard, percutaneous VSD closure by employing different types of occluders as an alternative for surgery can help to achieve the most desirable postprocedural consequences. However, the studies reported contradictory results on the use of different brands of VSD occluders. Herein, we performed a systematic review and meta-analysis of published studies to assess pooled long-term success rate and potential complications of using the Nit-Occlud Lê VSD coil for VSD closure. MATERIALS AND METHODS: Two reviewers began to deeply search the various databases for all eligible studies in accordance with the considered keywords. The inclusion criterion for retrieving the studies was to describe the mid-term or long-term consequences of VSD closing by the Nit-Occlud Lê VSD coil device. In the final, eight articles were eligible for the analysis. The follow-up time of the studies ranged from 6 months to 5 years. RESULTS: The success rate of the procedure ranged from 87.0% to 100% considering the weight of each study, the pooled success rate of VSDs closure by Nit-Occlud Lê VSD coil device was 93.1% (95% confidence interval [CI]: 89.9% to 95.5%). The pooled prevalence of postprocedural residual shunt was estimated to be 9.6% (95%CI: 6.8% to 13.4%). The corrected pooled prevalence of trivial mild aortic regurgitation (AR) was 2.9% (95%CI: 1.5% to 5.4%); however, moderate-to-severe AR and complete heart block or right bundle branch block were shown to be rare. CONCLUSION: VSD closure using a Nit-Occlud Lê VSD coil device can lead to a high success rate with low rates of residual shunt, cardiac conductive or vascular disturbances. Wolters Kluwer - Medknow 2022 2022-07-23 /pmc/articles/PMC9542967/ /pubmed/36213425 http://dx.doi.org/10.4103/heartviews.heartviews_97_21 Text en Copyright: © 2022 Heart Views https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Review Article Ghaderian, Mehdi Shahsanaei, Farzad Behdad, Samin Mozafari, Safura Long-term Consequences of Ventricular Septal Defect Closure Using Nit-Occlud Le VSD Coil Device: A Systematic Review and Meta-Analysis |
title | Long-term Consequences of Ventricular Septal Defect Closure Using Nit-Occlud Le VSD Coil Device: A Systematic Review and Meta-Analysis |
title_full | Long-term Consequences of Ventricular Septal Defect Closure Using Nit-Occlud Le VSD Coil Device: A Systematic Review and Meta-Analysis |
title_fullStr | Long-term Consequences of Ventricular Septal Defect Closure Using Nit-Occlud Le VSD Coil Device: A Systematic Review and Meta-Analysis |
title_full_unstemmed | Long-term Consequences of Ventricular Septal Defect Closure Using Nit-Occlud Le VSD Coil Device: A Systematic Review and Meta-Analysis |
title_short | Long-term Consequences of Ventricular Septal Defect Closure Using Nit-Occlud Le VSD Coil Device: A Systematic Review and Meta-Analysis |
title_sort | long-term consequences of ventricular septal defect closure using nit-occlud le vsd coil device: a systematic review and meta-analysis |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9542967/ https://www.ncbi.nlm.nih.gov/pubmed/36213425 http://dx.doi.org/10.4103/heartviews.heartviews_97_21 |
work_keys_str_mv | AT ghaderianmehdi longtermconsequencesofventricularseptaldefectclosureusingnitoccludlevsdcoildeviceasystematicreviewandmetaanalysis AT shahsanaeifarzad longtermconsequencesofventricularseptaldefectclosureusingnitoccludlevsdcoildeviceasystematicreviewandmetaanalysis AT behdadsamin longtermconsequencesofventricularseptaldefectclosureusingnitoccludlevsdcoildeviceasystematicreviewandmetaanalysis AT mozafarisafura longtermconsequencesofventricularseptaldefectclosureusingnitoccludlevsdcoildeviceasystematicreviewandmetaanalysis |