Reduction of Metal Artifacts Caused by Titanium Peduncular Screws in the Spine by Means of Monoenergetic Images and the Metal Artifact Reduction Software in Dual-Energy Computed Tomography

OBJECTIVES: To evaluate the reduction of metal artifacts in patients with titanium peduncular screws in the spine using (1) conventional images (CI), (2) virtual monoenergetic reconstructions (VMRs), and (3) VMR + Metal Artifact Reduction Software (VMR + MARS), with dual-energy computed tomography (...

Descripción completa

Detalles Bibliográficos
Autores principales: Ceccarelli, Luca, Vara, Giulio, Ponti, Federico, Miceli, Marco, Golfieri, Rita, Facchini, Giancarlo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9543003/
https://www.ncbi.nlm.nih.gov/pubmed/36212200
http://dx.doi.org/10.4103/jmp.jmp_121_21
_version_ 1784804275220643840
author Ceccarelli, Luca
Vara, Giulio
Ponti, Federico
Miceli, Marco
Golfieri, Rita
Facchini, Giancarlo
author_facet Ceccarelli, Luca
Vara, Giulio
Ponti, Federico
Miceli, Marco
Golfieri, Rita
Facchini, Giancarlo
author_sort Ceccarelli, Luca
collection PubMed
description OBJECTIVES: To evaluate the reduction of metal artifacts in patients with titanium peduncular screws in the spine using (1) conventional images (CI), (2) virtual monoenergetic reconstructions (VMRs), and (3) VMR + Metal Artifact Reduction Software (VMR + MARS), with dual-energy computed tomography (DECT). MATERIALS AND METHODS: Twenty-four patients with titanium peduncular screws in the spine were studied using a 64-channel DECT. During the postprocessing phase, the CI, the VMRs from 100 to 140 keV, and the VMR at 140 keV + MARS were synthesized. All the images were considered, and a quantitative evaluation was performed measuring the attenuation values (in terms of Hounsfield Units) with region of interest, in correspondence with the most hyperdense and hypodense artifacts. All the values were then compared. A qualitative evaluation, in terms of image quality and extent of artifacts, was also performed by two radiologists. RESULTS: In quantitative terms, the 140 keV + MARS reconstruction was able to significantly reduce both bright and dark metal artifacts, compared to CI and to VMRs. The VMR was capable of significantly reducing both dark and bright artifacts, compared to CI. In qualitative terms, the VMR at 140 keV proved to be the best, compared to CI and VMR + MARS images. CONCLUSIONS: The VMR + MARS image reduces metal artifacts from titanium peduncular screws more than VMRs alone and CI. Furthermore, the VMR can decrease metal artifacts from a quantitative and a qualitative point of view. Combining information from VMRs and VMR + MARS images could be the best way to solve the issue of metal artifacts on computed tomography images.
format Online
Article
Text
id pubmed-9543003
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-95430032022-10-08 Reduction of Metal Artifacts Caused by Titanium Peduncular Screws in the Spine by Means of Monoenergetic Images and the Metal Artifact Reduction Software in Dual-Energy Computed Tomography Ceccarelli, Luca Vara, Giulio Ponti, Federico Miceli, Marco Golfieri, Rita Facchini, Giancarlo J Med Phys Original Article OBJECTIVES: To evaluate the reduction of metal artifacts in patients with titanium peduncular screws in the spine using (1) conventional images (CI), (2) virtual monoenergetic reconstructions (VMRs), and (3) VMR + Metal Artifact Reduction Software (VMR + MARS), with dual-energy computed tomography (DECT). MATERIALS AND METHODS: Twenty-four patients with titanium peduncular screws in the spine were studied using a 64-channel DECT. During the postprocessing phase, the CI, the VMRs from 100 to 140 keV, and the VMR at 140 keV + MARS were synthesized. All the images were considered, and a quantitative evaluation was performed measuring the attenuation values (in terms of Hounsfield Units) with region of interest, in correspondence with the most hyperdense and hypodense artifacts. All the values were then compared. A qualitative evaluation, in terms of image quality and extent of artifacts, was also performed by two radiologists. RESULTS: In quantitative terms, the 140 keV + MARS reconstruction was able to significantly reduce both bright and dark metal artifacts, compared to CI and to VMRs. The VMR was capable of significantly reducing both dark and bright artifacts, compared to CI. In qualitative terms, the VMR at 140 keV proved to be the best, compared to CI and VMR + MARS images. CONCLUSIONS: The VMR + MARS image reduces metal artifacts from titanium peduncular screws more than VMRs alone and CI. Furthermore, the VMR can decrease metal artifacts from a quantitative and a qualitative point of view. Combining information from VMRs and VMR + MARS images could be the best way to solve the issue of metal artifacts on computed tomography images. Wolters Kluwer - Medknow 2022 2022-08-05 /pmc/articles/PMC9543003/ /pubmed/36212200 http://dx.doi.org/10.4103/jmp.jmp_121_21 Text en Copyright: © 2022 Journal of Medical Physics https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Ceccarelli, Luca
Vara, Giulio
Ponti, Federico
Miceli, Marco
Golfieri, Rita
Facchini, Giancarlo
Reduction of Metal Artifacts Caused by Titanium Peduncular Screws in the Spine by Means of Monoenergetic Images and the Metal Artifact Reduction Software in Dual-Energy Computed Tomography
title Reduction of Metal Artifacts Caused by Titanium Peduncular Screws in the Spine by Means of Monoenergetic Images and the Metal Artifact Reduction Software in Dual-Energy Computed Tomography
title_full Reduction of Metal Artifacts Caused by Titanium Peduncular Screws in the Spine by Means of Monoenergetic Images and the Metal Artifact Reduction Software in Dual-Energy Computed Tomography
title_fullStr Reduction of Metal Artifacts Caused by Titanium Peduncular Screws in the Spine by Means of Monoenergetic Images and the Metal Artifact Reduction Software in Dual-Energy Computed Tomography
title_full_unstemmed Reduction of Metal Artifacts Caused by Titanium Peduncular Screws in the Spine by Means of Monoenergetic Images and the Metal Artifact Reduction Software in Dual-Energy Computed Tomography
title_short Reduction of Metal Artifacts Caused by Titanium Peduncular Screws in the Spine by Means of Monoenergetic Images and the Metal Artifact Reduction Software in Dual-Energy Computed Tomography
title_sort reduction of metal artifacts caused by titanium peduncular screws in the spine by means of monoenergetic images and the metal artifact reduction software in dual-energy computed tomography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9543003/
https://www.ncbi.nlm.nih.gov/pubmed/36212200
http://dx.doi.org/10.4103/jmp.jmp_121_21
work_keys_str_mv AT ceccarelliluca reductionofmetalartifactscausedbytitaniumpeduncularscrewsinthespinebymeansofmonoenergeticimagesandthemetalartifactreductionsoftwareindualenergycomputedtomography
AT varagiulio reductionofmetalartifactscausedbytitaniumpeduncularscrewsinthespinebymeansofmonoenergeticimagesandthemetalartifactreductionsoftwareindualenergycomputedtomography
AT pontifederico reductionofmetalartifactscausedbytitaniumpeduncularscrewsinthespinebymeansofmonoenergeticimagesandthemetalartifactreductionsoftwareindualenergycomputedtomography
AT micelimarco reductionofmetalartifactscausedbytitaniumpeduncularscrewsinthespinebymeansofmonoenergeticimagesandthemetalartifactreductionsoftwareindualenergycomputedtomography
AT golfieririta reductionofmetalartifactscausedbytitaniumpeduncularscrewsinthespinebymeansofmonoenergeticimagesandthemetalartifactreductionsoftwareindualenergycomputedtomography
AT facchinigiancarlo reductionofmetalartifactscausedbytitaniumpeduncularscrewsinthespinebymeansofmonoenergeticimagesandthemetalartifactreductionsoftwareindualenergycomputedtomography