Elastic stent recoil in coronary total occlusions: Comparison of durable‐polymer zotarolimus eluting stent and ultrathin strut bioabsorbable‐polymer sirolimus eluting stent
OBJECTIVES: To compare stent recoil (SR) of the thin‐strut durable‐polymer Zotarolimus‐eluting stent (dp‐ZES) and the ultrathin‐strut bioabsorbable‐polymer Sirolimus‐eluting stent (bp‐SES) in chronic total occlusions (CTOs) and to investigate the predictors of high SR in CTOs. BACKGROUND: Newer ultr...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley & Sons, Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9543547/ https://www.ncbi.nlm.nih.gov/pubmed/33961730 http://dx.doi.org/10.1002/ccd.29739 |
_version_ | 1784804398509064192 |
---|---|
author | Improta, Riccardo Scarparo, Paola Wilschut, Jeroen Wolff, Quinten Daemen, Joost Den Dekker, Wijnand K Zijlstra, Felix Van Mieghem, Nicolas M Diletti, Roberto |
author_facet | Improta, Riccardo Scarparo, Paola Wilschut, Jeroen Wolff, Quinten Daemen, Joost Den Dekker, Wijnand K Zijlstra, Felix Van Mieghem, Nicolas M Diletti, Roberto |
author_sort | Improta, Riccardo |
collection | PubMed |
description | OBJECTIVES: To compare stent recoil (SR) of the thin‐strut durable‐polymer Zotarolimus‐eluting stent (dp‐ZES) and the ultrathin‐strut bioabsorbable‐polymer Sirolimus‐eluting stent (bp‐SES) in chronic total occlusions (CTOs) and to investigate the predictors of high SR in CTOs. BACKGROUND: Newer ultrathin drug eluting stent might be associated with lower radial force and higher elastic recoil due to the thinner strut design, possibly impacting on the rate of in‐stent restenosis and thrombosis. METHODS: Between January 2017 and November 2019, consecutive patients with CTOs undergoing percutaneous coronary intervention were evaluated. Only patients treated with dp‐ZES or bp‐SES were included and stratified accordingly. Quantitative coronary angiography analysis was used to assess absolute SR, relative SR, absolute focal SR, relative focal SR, high absolute, and high relative focal SR. RESULTS: A total of 128 lesions (67 treated with dp‐ZES and 61 with bp‐SES) in 123 patients were analyzed. Between bp‐SES and dp‐ZES no differences were found in absolute SR (p = .188), relative SR (p = .138), absolute focal SR (p = .069), and relative focal SR (p = .064). High absolute and high relative focal SR occurred more frequently in bp‐SES than in dp‐ZES (p = .004 and p = .015). Bp‐SES was a predictor of high absolute focal SR (Odds ratio [OR] 3.29, 95% confidence interval [CI] 1.50–7.22, p = .003]. High‐pressure postdilation and bp‐SES were predictors of high relative focal SR (OR 2.22, 95% CI 1.01–4.86, p = .047; OR 2.74, 95% CI 1.24–6.02, p = .012, respectively). CONCLUSIONS: Both stents showed an overall low SR. However, ultra‐thin strut bp‐SES was a predictor of high absolute and high relative focal SR. |
format | Online Article Text |
id | pubmed-9543547 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley & Sons, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-95435472022-10-14 Elastic stent recoil in coronary total occlusions: Comparison of durable‐polymer zotarolimus eluting stent and ultrathin strut bioabsorbable‐polymer sirolimus eluting stent Improta, Riccardo Scarparo, Paola Wilschut, Jeroen Wolff, Quinten Daemen, Joost Den Dekker, Wijnand K Zijlstra, Felix Van Mieghem, Nicolas M Diletti, Roberto Catheter Cardiovasc Interv Coronary Artery Disease OBJECTIVES: To compare stent recoil (SR) of the thin‐strut durable‐polymer Zotarolimus‐eluting stent (dp‐ZES) and the ultrathin‐strut bioabsorbable‐polymer Sirolimus‐eluting stent (bp‐SES) in chronic total occlusions (CTOs) and to investigate the predictors of high SR in CTOs. BACKGROUND: Newer ultrathin drug eluting stent might be associated with lower radial force and higher elastic recoil due to the thinner strut design, possibly impacting on the rate of in‐stent restenosis and thrombosis. METHODS: Between January 2017 and November 2019, consecutive patients with CTOs undergoing percutaneous coronary intervention were evaluated. Only patients treated with dp‐ZES or bp‐SES were included and stratified accordingly. Quantitative coronary angiography analysis was used to assess absolute SR, relative SR, absolute focal SR, relative focal SR, high absolute, and high relative focal SR. RESULTS: A total of 128 lesions (67 treated with dp‐ZES and 61 with bp‐SES) in 123 patients were analyzed. Between bp‐SES and dp‐ZES no differences were found in absolute SR (p = .188), relative SR (p = .138), absolute focal SR (p = .069), and relative focal SR (p = .064). High absolute and high relative focal SR occurred more frequently in bp‐SES than in dp‐ZES (p = .004 and p = .015). Bp‐SES was a predictor of high absolute focal SR (Odds ratio [OR] 3.29, 95% confidence interval [CI] 1.50–7.22, p = .003]. High‐pressure postdilation and bp‐SES were predictors of high relative focal SR (OR 2.22, 95% CI 1.01–4.86, p = .047; OR 2.74, 95% CI 1.24–6.02, p = .012, respectively). CONCLUSIONS: Both stents showed an overall low SR. However, ultra‐thin strut bp‐SES was a predictor of high absolute and high relative focal SR. John Wiley & Sons, Inc. 2021-05-07 2022-01-01 /pmc/articles/PMC9543547/ /pubmed/33961730 http://dx.doi.org/10.1002/ccd.29739 Text en © 2021 The Authors. Catheterization and Cardiovascular Interventions published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Coronary Artery Disease Improta, Riccardo Scarparo, Paola Wilschut, Jeroen Wolff, Quinten Daemen, Joost Den Dekker, Wijnand K Zijlstra, Felix Van Mieghem, Nicolas M Diletti, Roberto Elastic stent recoil in coronary total occlusions: Comparison of durable‐polymer zotarolimus eluting stent and ultrathin strut bioabsorbable‐polymer sirolimus eluting stent |
title | Elastic stent recoil in coronary total occlusions: Comparison of durable‐polymer zotarolimus eluting stent and ultrathin strut bioabsorbable‐polymer sirolimus eluting stent |
title_full | Elastic stent recoil in coronary total occlusions: Comparison of durable‐polymer zotarolimus eluting stent and ultrathin strut bioabsorbable‐polymer sirolimus eluting stent |
title_fullStr | Elastic stent recoil in coronary total occlusions: Comparison of durable‐polymer zotarolimus eluting stent and ultrathin strut bioabsorbable‐polymer sirolimus eluting stent |
title_full_unstemmed | Elastic stent recoil in coronary total occlusions: Comparison of durable‐polymer zotarolimus eluting stent and ultrathin strut bioabsorbable‐polymer sirolimus eluting stent |
title_short | Elastic stent recoil in coronary total occlusions: Comparison of durable‐polymer zotarolimus eluting stent and ultrathin strut bioabsorbable‐polymer sirolimus eluting stent |
title_sort | elastic stent recoil in coronary total occlusions: comparison of durable‐polymer zotarolimus eluting stent and ultrathin strut bioabsorbable‐polymer sirolimus eluting stent |
topic | Coronary Artery Disease |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9543547/ https://www.ncbi.nlm.nih.gov/pubmed/33961730 http://dx.doi.org/10.1002/ccd.29739 |
work_keys_str_mv | AT improtariccardo elasticstentrecoilincoronarytotalocclusionscomparisonofdurablepolymerzotarolimuselutingstentandultrathinstrutbioabsorbablepolymersirolimuselutingstent AT scarparopaola elasticstentrecoilincoronarytotalocclusionscomparisonofdurablepolymerzotarolimuselutingstentandultrathinstrutbioabsorbablepolymersirolimuselutingstent AT wilschutjeroen elasticstentrecoilincoronarytotalocclusionscomparisonofdurablepolymerzotarolimuselutingstentandultrathinstrutbioabsorbablepolymersirolimuselutingstent AT wolffquinten elasticstentrecoilincoronarytotalocclusionscomparisonofdurablepolymerzotarolimuselutingstentandultrathinstrutbioabsorbablepolymersirolimuselutingstent AT daemenjoost elasticstentrecoilincoronarytotalocclusionscomparisonofdurablepolymerzotarolimuselutingstentandultrathinstrutbioabsorbablepolymersirolimuselutingstent AT dendekkerwijnandk elasticstentrecoilincoronarytotalocclusionscomparisonofdurablepolymerzotarolimuselutingstentandultrathinstrutbioabsorbablepolymersirolimuselutingstent AT zijlstrafelix elasticstentrecoilincoronarytotalocclusionscomparisonofdurablepolymerzotarolimuselutingstentandultrathinstrutbioabsorbablepolymersirolimuselutingstent AT vanmieghemnicolasm elasticstentrecoilincoronarytotalocclusionscomparisonofdurablepolymerzotarolimuselutingstentandultrathinstrutbioabsorbablepolymersirolimuselutingstent AT dilettiroberto elasticstentrecoilincoronarytotalocclusionscomparisonofdurablepolymerzotarolimuselutingstentandultrathinstrutbioabsorbablepolymersirolimuselutingstent |