Retinal oximetry with a prototype handheld oximeter during hyperoxia

PURPOSE: Retinal oximetry measures oxygen saturation in retinal vessels. With the introduction of a mobile handheld prototype oximeter, this technique will become available for a broader patient population including bedridden patients and newborn babies. The objective is to determine the sensitivity...

Descripción completa

Detalles Bibliográficos
Autores principales: Vehmeijer, Wouter B., Jonkman, Kelly, Hardarson, Sveinn H., Aarts, Leon, Stefansson, Einar, Dahan, Albert, Schalij‐Delfos, Nicoline E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9543559/
https://www.ncbi.nlm.nih.gov/pubmed/33650317
http://dx.doi.org/10.1111/aos.14817
_version_ 1784804401036132352
author Vehmeijer, Wouter B.
Jonkman, Kelly
Hardarson, Sveinn H.
Aarts, Leon
Stefansson, Einar
Dahan, Albert
Schalij‐Delfos, Nicoline E.
author_facet Vehmeijer, Wouter B.
Jonkman, Kelly
Hardarson, Sveinn H.
Aarts, Leon
Stefansson, Einar
Dahan, Albert
Schalij‐Delfos, Nicoline E.
author_sort Vehmeijer, Wouter B.
collection PubMed
description PURPOSE: Retinal oximetry measures oxygen saturation in retinal vessels. With the introduction of a mobile handheld prototype oximeter, this technique will become available for a broader patient population including bedridden patients and newborn babies. The objective is to determine the sensitivity of this handheld oximeter in room air and during isocapnic hyperoxia. A comparison is made between the handheld oximeter and the Oxymap T1. METHODS: Thirteen young healthy subjects with a mean age of 25 ± 2 years were recruited at the Leiden University Medical Center. Retinal oximetry images were acquired during normoxia and during isocapnic hyperoxia for both the prototype oximeter and the OxymapT1. Isocapnic hyperoxia was induced with the dynamic end‐tidal forcing technique. For both oximeters, the oxygen saturation and vessel width were measured with Oxymap Analyzer software. The hyperoxic state was verified with blood gas analysis. RESULTS: The mean oxygen saturation measured with the handheld oximeter in arterioles was 91.3% ± 3.9% during normoxia and 94.6% ± 3.9% during hyperoxia (p = 0.001). Oxygen saturation in venules was 56.3% ± 9.8% during normoxia and 82.2 ± 7.4% during hyperoxia (p < 0.001). For the Oxymap T1, the mean oxygen saturation for arterioles was 94.0% ± 2.6% during normoxia and 95.4%±3.2% during hyperoxia (p = 0.004). For the venules, the oxygen saturation was during normoxia 58.9%±3.2% and 84.3 ± 4.0% during hyperoxia (p < 0.001). CONCLUSION: The handheld retinal oximeter is sensitive to the changes in inhaled oxygen concentration. A small increase in oxygen saturation was measured in the arterioles and a larger increase in the venules. The handheld oximeter gives similar values as the ‘gold standard’ Oxymap T1 oximeter.
format Online
Article
Text
id pubmed-9543559
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-95435592022-10-14 Retinal oximetry with a prototype handheld oximeter during hyperoxia Vehmeijer, Wouter B. Jonkman, Kelly Hardarson, Sveinn H. Aarts, Leon Stefansson, Einar Dahan, Albert Schalij‐Delfos, Nicoline E. Acta Ophthalmol Original Articles PURPOSE: Retinal oximetry measures oxygen saturation in retinal vessels. With the introduction of a mobile handheld prototype oximeter, this technique will become available for a broader patient population including bedridden patients and newborn babies. The objective is to determine the sensitivity of this handheld oximeter in room air and during isocapnic hyperoxia. A comparison is made between the handheld oximeter and the Oxymap T1. METHODS: Thirteen young healthy subjects with a mean age of 25 ± 2 years were recruited at the Leiden University Medical Center. Retinal oximetry images were acquired during normoxia and during isocapnic hyperoxia for both the prototype oximeter and the OxymapT1. Isocapnic hyperoxia was induced with the dynamic end‐tidal forcing technique. For both oximeters, the oxygen saturation and vessel width were measured with Oxymap Analyzer software. The hyperoxic state was verified with blood gas analysis. RESULTS: The mean oxygen saturation measured with the handheld oximeter in arterioles was 91.3% ± 3.9% during normoxia and 94.6% ± 3.9% during hyperoxia (p = 0.001). Oxygen saturation in venules was 56.3% ± 9.8% during normoxia and 82.2 ± 7.4% during hyperoxia (p < 0.001). For the Oxymap T1, the mean oxygen saturation for arterioles was 94.0% ± 2.6% during normoxia and 95.4%±3.2% during hyperoxia (p = 0.004). For the venules, the oxygen saturation was during normoxia 58.9%±3.2% and 84.3 ± 4.0% during hyperoxia (p < 0.001). CONCLUSION: The handheld retinal oximeter is sensitive to the changes in inhaled oxygen concentration. A small increase in oxygen saturation was measured in the arterioles and a larger increase in the venules. The handheld oximeter gives similar values as the ‘gold standard’ Oxymap T1 oximeter. John Wiley and Sons Inc. 2021-03-01 2021-12 /pmc/articles/PMC9543559/ /pubmed/33650317 http://dx.doi.org/10.1111/aos.14817 Text en © 2021 The Authors. Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Articles
Vehmeijer, Wouter B.
Jonkman, Kelly
Hardarson, Sveinn H.
Aarts, Leon
Stefansson, Einar
Dahan, Albert
Schalij‐Delfos, Nicoline E.
Retinal oximetry with a prototype handheld oximeter during hyperoxia
title Retinal oximetry with a prototype handheld oximeter during hyperoxia
title_full Retinal oximetry with a prototype handheld oximeter during hyperoxia
title_fullStr Retinal oximetry with a prototype handheld oximeter during hyperoxia
title_full_unstemmed Retinal oximetry with a prototype handheld oximeter during hyperoxia
title_short Retinal oximetry with a prototype handheld oximeter during hyperoxia
title_sort retinal oximetry with a prototype handheld oximeter during hyperoxia
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9543559/
https://www.ncbi.nlm.nih.gov/pubmed/33650317
http://dx.doi.org/10.1111/aos.14817
work_keys_str_mv AT vehmeijerwouterb retinaloximetrywithaprototypehandheldoximeterduringhyperoxia
AT jonkmankelly retinaloximetrywithaprototypehandheldoximeterduringhyperoxia
AT hardarsonsveinnh retinaloximetrywithaprototypehandheldoximeterduringhyperoxia
AT aartsleon retinaloximetrywithaprototypehandheldoximeterduringhyperoxia
AT stefanssoneinar retinaloximetrywithaprototypehandheldoximeterduringhyperoxia
AT dahanalbert retinaloximetrywithaprototypehandheldoximeterduringhyperoxia
AT schalijdelfosnicolinee retinaloximetrywithaprototypehandheldoximeterduringhyperoxia