Cargando…

Preclinical dosimetry in proton minibeam radiation therapy: Robustness analysis and guidelines

PURPOSE: Proton minibeam radiation therapy (pMBRT) is a new radiotherapy approach that has shown a significant increase in the therapeutic window in glioma‐bearing rats compared to conventional proton therapy. The dosimetry of pMBRT is challenging and error prone due to the submillimetric beamlet si...

Descripción completa

Detalles Bibliográficos
Autores principales: Ortiz, Ramon, De Marzi, Ludovic, Prezado, Yolanda
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9544651/
https://www.ncbi.nlm.nih.gov/pubmed/35621386
http://dx.doi.org/10.1002/mp.15780
_version_ 1784804643697590272
author Ortiz, Ramon
De Marzi, Ludovic
Prezado, Yolanda
author_facet Ortiz, Ramon
De Marzi, Ludovic
Prezado, Yolanda
author_sort Ortiz, Ramon
collection PubMed
description PURPOSE: Proton minibeam radiation therapy (pMBRT) is a new radiotherapy approach that has shown a significant increase in the therapeutic window in glioma‐bearing rats compared to conventional proton therapy. The dosimetry of pMBRT is challenging and error prone due to the submillimetric beamlet sizes used. The aim of this study was to perform a robustness analysis on the setup parameters utilized in current preclinical trials and provide guidelines for reproducible dosimetry. The results of this work are intended to guide upcoming implementations of pMBRT worldwide, as well as pave the way for future clinical implementations. METHODS: Monte Carlo simulations and experimental data were used to evaluate the impact of variations in setup parameters and uncertainties in collimator specifications on lateral pMBRT dose distributions. The value of each parameter was modified individually to evaluate their effect on dose distributions. Experimental dosimetry was performed by means of high‐resolution detectors, that is, radiochromic films, the IBA Razor and the Microdiamond detector. New guidelines were proposed to optimize the experimental setup in pMBRT studies and perform reproducible dosimetry. RESULTS: The sensitivity of dose distributions to uncertainties and variations in setup parameters was quantified. Quantities that define pMBRT lateral profiles (i.e., the peak‐to‐valley dose ratio [PVDR], peak and valley doses, and peak width) are significantly influenced by small‐scale fluctuations in several of those parameters. The setup implemented at the Orsay proton therapy center for pMBRT irradiation was optimized to increase PVDRs and peak symmetry. In addition, we proposed guidelines to perform accurate and reproducible dosimetry in preclinical studies. CONCLUSIONS: This study revealed the importance of adopting guidelines and protocols tailored to the distinct dose delivery method and dose distributions in pMBRT. This new methodology leads to reproducible dosimetry, which is imperative in preclinical trials. The results and guidelines presented in this manuscript can ease the initiation of pMBRT investigations in other centers.
format Online
Article
Text
id pubmed-9544651
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-95446512022-10-14 Preclinical dosimetry in proton minibeam radiation therapy: Robustness analysis and guidelines Ortiz, Ramon De Marzi, Ludovic Prezado, Yolanda Med Phys COMPUTATIONAL AND EXPERIMENTAL DOSIMETRY PURPOSE: Proton minibeam radiation therapy (pMBRT) is a new radiotherapy approach that has shown a significant increase in the therapeutic window in glioma‐bearing rats compared to conventional proton therapy. The dosimetry of pMBRT is challenging and error prone due to the submillimetric beamlet sizes used. The aim of this study was to perform a robustness analysis on the setup parameters utilized in current preclinical trials and provide guidelines for reproducible dosimetry. The results of this work are intended to guide upcoming implementations of pMBRT worldwide, as well as pave the way for future clinical implementations. METHODS: Monte Carlo simulations and experimental data were used to evaluate the impact of variations in setup parameters and uncertainties in collimator specifications on lateral pMBRT dose distributions. The value of each parameter was modified individually to evaluate their effect on dose distributions. Experimental dosimetry was performed by means of high‐resolution detectors, that is, radiochromic films, the IBA Razor and the Microdiamond detector. New guidelines were proposed to optimize the experimental setup in pMBRT studies and perform reproducible dosimetry. RESULTS: The sensitivity of dose distributions to uncertainties and variations in setup parameters was quantified. Quantities that define pMBRT lateral profiles (i.e., the peak‐to‐valley dose ratio [PVDR], peak and valley doses, and peak width) are significantly influenced by small‐scale fluctuations in several of those parameters. The setup implemented at the Orsay proton therapy center for pMBRT irradiation was optimized to increase PVDRs and peak symmetry. In addition, we proposed guidelines to perform accurate and reproducible dosimetry in preclinical studies. CONCLUSIONS: This study revealed the importance of adopting guidelines and protocols tailored to the distinct dose delivery method and dose distributions in pMBRT. This new methodology leads to reproducible dosimetry, which is imperative in preclinical trials. The results and guidelines presented in this manuscript can ease the initiation of pMBRT investigations in other centers. John Wiley and Sons Inc. 2022-06-08 2022-08 /pmc/articles/PMC9544651/ /pubmed/35621386 http://dx.doi.org/10.1002/mp.15780 Text en © 2022 The Authors. Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle COMPUTATIONAL AND EXPERIMENTAL DOSIMETRY
Ortiz, Ramon
De Marzi, Ludovic
Prezado, Yolanda
Preclinical dosimetry in proton minibeam radiation therapy: Robustness analysis and guidelines
title Preclinical dosimetry in proton minibeam radiation therapy: Robustness analysis and guidelines
title_full Preclinical dosimetry in proton minibeam radiation therapy: Robustness analysis and guidelines
title_fullStr Preclinical dosimetry in proton minibeam radiation therapy: Robustness analysis and guidelines
title_full_unstemmed Preclinical dosimetry in proton minibeam radiation therapy: Robustness analysis and guidelines
title_short Preclinical dosimetry in proton minibeam radiation therapy: Robustness analysis and guidelines
title_sort preclinical dosimetry in proton minibeam radiation therapy: robustness analysis and guidelines
topic COMPUTATIONAL AND EXPERIMENTAL DOSIMETRY
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9544651/
https://www.ncbi.nlm.nih.gov/pubmed/35621386
http://dx.doi.org/10.1002/mp.15780
work_keys_str_mv AT ortizramon preclinicaldosimetryinprotonminibeamradiationtherapyrobustnessanalysisandguidelines
AT demarziludovic preclinicaldosimetryinprotonminibeamradiationtherapyrobustnessanalysisandguidelines
AT prezadoyolanda preclinicaldosimetryinprotonminibeamradiationtherapyrobustnessanalysisandguidelines