POD–Kalman filtering for improving noninvasive 3D temperature monitoring in MR‐guided hyperthermia
BACKGROUND: During resonance frequency (RF) hyperthermia treatment, the temperature of the tumor tissue is elevated to the range of 39–44°C. Accurate temperature monitoring is essential to guide treatments and ensure precise heat delivery and treatment quality. Magnetic resonance (MR) thermometry is...
Autores principales: | VilasBoas‐Ribeiro, Iva, Nouwens, Sven A.N., Curto, Sergio, de Jager, Bram, Franckena, Martine, van Rhoon, Gerard C., Heemels, W. P. M. H., Paulides, Margarethus M. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9545729/ https://www.ncbi.nlm.nih.gov/pubmed/35717578 http://dx.doi.org/10.1002/mp.15811 |
Ejemplares similares
-
MR Thermometry Accuracy and Prospective Imaging-Based Patient Selection in MR-Guided Hyperthermia Treatment for Locally Advanced Cervical Cancer
por: VilasBoas-Ribeiro, Iva, et al.
Publicado: (2021) -
Impact of Number of Segmented Tissues on SAR Prediction Accuracy in Deep Pelvic Hyperthermia Treatment Planning
por: VilasBoas-Ribeiro, Iva, et al.
Publicado: (2020) -
Clinical Performance and Future Potential of Magnetic Resonance Thermometry in Hyperthermia
por: Feddersen, Theresa V., et al.
Publicado: (2020) -
Feasibility, SAR Distribution, and Clinical Outcome upon Reirradiation and Deep Hyperthermia Using the Hypercollar3D in Head and Neck Cancer Patients
por: Kroesen, Michiel, et al.
Publicado: (2021) -
The Potential of Adjusting Water Bolus Liquid Properties for Economic and Precise MR Thermometry Guided Radiofrequency Hyperthermia
por: Sumser, Kemal, et al.
Publicado: (2020)